文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,389+ SCI 论文 与阿拉丁产品引用相关
2,303,681.05 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第2785至2786个,产品总数2,786个

切换升序
ZnO
ANALYTICAL CHEMISTRY · 2024 · IF 6.7

SILAR Growth of ZnO NSs/CdS QDs on the Optical Fiber-Based Opto-Electrode with Guided In Situ Light and Its Application for the “Signal-On” Detection of Inflammatory Cytokine

Huiyu Zou,Wuming Wu,Jingjing Zhou,Chunyan Deng

In this study, a novel integrated photoelectrochemical (PEC) sensor platform was proposed, utilizing an optical fiber (OF) as the working electrode for guided in situ light. A CdS quantum dots (QDs)/ZnO nanosheets (NSs) n-n heterojunction was quickly and easily constructed on the OF surface by successive ionic layer adsorption and reaction (SILAR). Au nanoparticles (NPs)@dsDNA as a capturing probe were modified on the CdS QDs/ZnO NSs@OF (CZ@OF). Due to the energy transfer between Au NPs@dsDNA and CdS QDs, the resultant opto-electrode has a lower background near zero, enabling the “signal-on” detection of biomarkers (interleukin-6 (IL-6) as a model). The OF-PEC biosensor demonstrated a wide linear range from 1 to 100 pg mL–1 with a regression coefficient (R2) of 0.9958 and an impressive detection limit (LOD) of 0.19 pg mL–1. More significantly, the proposed OF-PEC can be successfully used for the detection of IL-6 in serum samples from patients with pulmonary arterial hypertension, and it showed consistency and is more sensitive to trace concentrations compared to BD FACSCanto II flow cytometry used at the hospital. This holds significance for an early disease diagnosis. Therefore, the proposed OF-PEC not only achieves integration of the light source and sensing interface but also enables sensitive and accurate “signal-on” detection of IL-6. Furthermore, due to the flexibility and remote detection capabilities of OF, the application of OF-PEC is expected to be expanded more widely. This approach opens up possibilities for advances in PEC sensing.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Sensors · 2025 · IF 9.1

Smart Breath Sentinel: A NO2 Gas Sensor with ppt-Level Detection Lower Limit and High Signal-to-Noise Ratio Based on In(OH)3-α-Fe2O3–ZnO for an Application on Intelligent Upgrade of Ordinary Masks

Xiao Ma,Rong Tan,Hong Chen,Jiawei Zhang,Lei Ge,Tingting Zhao,Xinyu Wang,Kaikai Yuan,Hairui Fang,Dong Wang

Nitrogen dioxide (NO2), the main component of pollutants in atmospheric environments, causes and exacerbates respiratory diseases, especially during outdoor sports even at the 100 ppb level. Currently, environmental gas detection still faces challenges such as high detection limits, low SNR, and low sensitivity. A NO2 sensor based on In(OH)3-α-Fe2O3–ZnO was prepared using a hydrothermal method, featuring an ultralow detection limit of 82 ppt, an exceptionally high SNR of 574,000, and an ultrahigh sensitivity of 252.25 mV/ppm (100 ppb to 1 ppm). And this sensor exhibits excellent response, selectivity, and repeatability. These excellent sensing characteristics come from the adsorbed oxygen on the surface of the material with the formation of n–n heterojunctions. Additionally, a low-power, portable, and cost-effective environmental monitoring system (named Smart Breath Sentinel (SBS)) was designed to intelligently upgrade ordinary masks. SBS enables real-time wireless environmental gas monitoring with integrated humidity compensation to ensure accurate measurements in high-humidity environments. SBS has already been tested in multiple environments, and the test results have proven the feasibility of SBS. This sensor based on In(OH)3-α-Fe2O3–ZnO demonstrates significant potential for applications aimed at enhancing human safety.

CAS / MDL: 62-56-6 9003-11-6
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。