文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,389+ SCI 论文 与阿拉丁产品引用相关
2,303,681.05 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第2845至2856个,产品总数3,922个

切换升序
MXene
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2025 · IF 9.7

Enabling electron redistribution via electron-deficient boron quantum dots confined in Ti3C2 MXene for fast lithium-ion storage

Yuxuan Zhang,Junzhe Zhang,Hongming Zhao,Danfeng Zhang,Mei Wang,Peng Li,Liyong Wang,Yan-Bing He,Huiqi Wang

Quantum dots have been extensively utilized in diverse components of lithium-ion batteries (LIBs) due to their distinctive electronic structures, extremely high specific surface area, and remarkable interfacial regulation ability. In this work, a facile liquid-phase exfoliation method was employed to break down bulk boron into quantum-sized dots using a probe high-power ultrasonic crusher. The obtained boron quantum dots (BQDs) were confined within highly dispersed Ti 3 C 2 MXene, thereby forming BQDs/Ti 3 C 2 stacked composite anode materials for lithium-ion batteries. Based on the quantum confinement effect, BQDs exhibit superior electrochemical activity compared to bulk boron, providing abundant active sites for ion insertion and extraction. The well-dispersed BQDs in the Ti 3 C 2 MXene form a continuous network, facilitating efficient charge and ion diffusion and transport throughout the entire structure. Electron deficiency induced by BQDs occurs in the interlayers of Ti 3 C 2 MXene, thus the local electronic defect is introduced into the originally perfect periodic atomic arrangement and electronic potential field. This would cause ripples in the entire electronic system, leading to a redistribution of electrons. This not only enhances the charge transfer kinetics but also modulates the lithium-ion diffusion pathways through local electric field intensification. The as-prepared BQDs/Ti 3 C 2 stacked composite thus delivers an extremely high initial discharge capacity of 2514.5 mAh g −1 at 0.05 A g −1 , a large reversible capacity of 835.3 mAh g −1 at 0.1 A g −1 , and outstanding long-term cycle stability, with 958.0 mAh g −1 retained after 300 cycles. Notably, it also demonstrates exceptional long-term cycling performance at 2.0 A g −1 , with the capacity increasing from 459.5 mAh g −1 after 163 cycles to 1251.7 mAh g −1 after 759 cycles. The exploration of BQDs embedded in Ti 3 C 2 MXene is anticipated to inspire in-depth investigations into advanced BQD-powered MXene anode materials for LIBs.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
APPLIED SURFACE SCIENCE · 2025 · IF 6.9

Mxene-supported cobalt-molybdenum bimetallic phosphide constructs heterojunctions to regulate the electronic structure for efficient alkaline water splitting

Desheng Guo,Wei Tan,Xu Guo,Lingling Wen,Xin Li

Transition metal phosphides have garnered substantial attention as highly promising catalysts for alkaline water electrolysis. However, the agglomeration tendency of transition metal phosphides and their limited electronic tunability have restricted their further development as bifunctional water electrolysis catalysts. This study proposes a simple and efficient strategy of strong electrostatic adsorption-electrodeposition to prepare a CoMo-P@MXene/NF bifunctional catalyst with a rough surface structure on foam nickel. Ti 3 C 2 T x MXene, with its excellent surface physicochemical properties, not only inhibits the agglomeration of transition metal phosphides but also enhances the conductivity and hydrophilicity of the catalyst, accelerating the penetration of the electrolyte. Moreover, DFT calculations and experimental validation indicate that the heterojunction formed by coupling cobalt-molybdenum transition bimetallic phosphides with Ti 3 C 2 T x MXene modifies the electronic configuration of the active sites. This not only decreases the dissociation energy barrier of water molecules but also optimizes the adsorption/desorption free energy of intermediates in water electrolysis reactions on the catalyst surface, thus expediting the catalytic reaction kinetics of the HER and OER. In 1 M KOH solution, the CoMo-P@MXene/NF catalyst, functioning as a bifunctional catalyst, necessitates overpotentials of merely 35.2 mV and 193 mV for HER and OER, respectively, to attain a current density of 10 mA cm −2 . Furthermore, an alkaline electrolyzer constituted by CoMo-P@MXene/NF requires only a full water-splitting voltage of 1.46 V to reach a current density of 10 mA cm −2 . This study provides a reference for the preparation of transition metal phosphide/two-dimensional MXene heterostructure catalysts.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2025 · IF 7.7

Rational fabrication of a ratiometric electrochemical aptasensor based on 3D AuNPs/MXene/rGO composite for ultrasensitive homocysteine biosensing

Fuxin Liu,Wenyan Li,Fang Nian,Haitao Long,Lumei Pu,Xiuhui Liu

Homocysteine (Hcy) is a key biomarker for various diseases, and its precise detection is essential for early clinical diagnosis. Herein, an innovative ratiometric electrochemical aptasensor was constructed to overcome the limitations in sensitivity, selectivity, and stability in conventional Hcy detection methods. Firstly, we synthesized a novel 3D MXene/rGO aerogel loaded AuNPs composite (Au/MGA-40) with outstanding specific surface area and remarkable electrical conductivity. Next, the Hcy aptamer was self-assembled to the Au/MGA-40/MB modified electrode surface by gold sulfur bonds (Au-S). Finally, a ratiometric detection mode was established based on the linear relationship between the oxidation peak current ratios (I Hcy /I MB ) and the Hcy concentrations. The aptasensor exhibited excellent analytical behavior for Hcy, with a ultrawide detection range from 2.14   nM to 200   μM and a detection limit as low as 0.835   nM. It also displayed remarkable selectivity due to the specific recognition between Hcy and the aptamer, enabling discrimination of Hcy from structurally similar molecules such as cysteine (Cys), glutathione (GSH) and methionine (Met). The ratio signal mode demonstrated superior long-term stability performance compared to conventional single signal sensors. As evidenced by the successful detection of Hcy in human serum, which underscores its potential for early screening of Hcy-related diseases.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2025 · IF 2.6

Ni/Ag bimetallic nanoparticle-engineered Ti3C2Tx MXene composite as a SERS substrate for trace detection of thiram pesticide

Jinping Tang,Yuhai Wang,Chunxu Wang,Ziwei Yu,Jin Wang

Surface-enhanced Raman scattering (SERS) has emerged as a powerful analytical tool for trace molecular detection, enabling identification of target analytes through their characteristic vibrational fingerprints. Its high sensitivity, selectivity, and non-destructive detection capabilities make it extremely valuable in fields such as biological detection, food safety, and environmental detection. Currently, metal carbonitride (MXene) as an emerging two-dimensional material has become a hot topic in the field of SERS. In this work, by combining the advantages of bimetallic nanoparticles and MXene nanosheets, Ni/Ag nanoparticles with different proportions were modified on monolayer MXene nanosheets through chemical reduction and transmetallation reactions for the rapid detection of thiram. The evaluation of the SERS performance of the MXene–Ni/Ag composite substrate for the Raman reporter molecule mercaptobenzoic acid (MBA) demonstrates a high SERS performance factor (SPF) of 8.2 × 106, and a low detection limit of 10−10 M. Also, for the detection of the pesticide thiram, the substrate exhibits high sensitivity and reliable quantitative analysis capabilities, retaining detectable spectral features even at concentrations down to 10−9 M. Meanwhile, the substrate also exhibits a low relative standard deviation (RSD) value in reproducibility and maintains good stability over a certain period. Ni/Ag bimetallic nanoparticles provide high SERS activity, while MXene nanosheets effectively concentrate target molecules through their strong adsorption capacity. These results indicate that MXene–Ni/Ag composite substrates can serve as a highly effective SERS platform for sensitive and reliable environmental monitoring.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2025 · IF 13.2

BreathFIT: Liquid metal-PDMS sticky conductors and AuNPs/MXene biosensors for synchronous EMG-lactate monitoring in respiratory health

Yang Liu,Zixin Lin,Yuetao Zhang,Xinyu Zhang,Zhiqi Li,Rubing Xiong,Chunxiao Long,Jiaqi Huang,Can Liu,Ziwei Zheng,Dan Li,Yongchang Ouyang,Lei Mou

In view of the need for real-time, multimodal respiratory health monitoring, we present a wearable sensor platform (BreathFIT) that simultaneously measures lactate and electromyography (EMG) signals for assessment of diaphragm function. By virtue of integrating liquid metal-polydimethylsiloxane (LM-PDMS) flexible sticky conductors for EMG acquisition with a lactate screen-printed electrode (LSPE), the platform enables concurrent measurement of muscle electrical activity and metabolic byproducts (lactate) from the diaphragm. Data are captured and visualized in real time via custom software, enabling machine learning models (LSTM, DNN, SVM, Random Forest) to classify diaphragm activity patterns during rest, exercise, and sleep. Owing to its integrated design, the system exhibits stable electrochemical performance, exceptional mechanical compliance (300 % stretchability), excellent skin conformality (39 N cm −1 adhesion strength), and high accuracy in distinguishing diaphragm states. Consequently, all models demonstrate high classification accuracy, with Random Forest proving the most effective at capturing time-series features (accuracy = 92.19 %). The dual-modality platform uniquely integrates electrical and biochemical sensing with intelligent analysis. This configuration enables high spatiotemporal-resolution monitoring of respiratory muscle activity. Consequently, the system opens a new avenue for wearable multimodal health monitoring, providing significant potential for both clinical and at-home respiratory health management.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Materials Chemistry A · 2025 · IF 9.5

Laser-induced MXene/LIG Ternary Heterostructure: Construction and Health Monitoring Application of High Performance Self-powered Friction Sensor

Qiancheng Liu,Changxia Liu,Xudong Wei,Junlong Sun,Xueye Chen

This study adopts an innovative strategy that combines laser-induced technology with chemical bonding to construct flexible MXene/LIG @laser (MLL) composite films with a ternary heterostructure of V2CTx-LIG-V2O5, which were assembled into a flexible triboelectric nanogenerator (MLL-TENG) with a single electrode structure. An open-circuit voltage (VOC) of 200.69V and short-circuit current (ISC) of 4.44μA were achieved using the MLL-TENG. System characterization showed that the MLL-TENG had excellent mechanical durability (>6000 cycles, decay rate of 2.8%), high sensitivity (22.64 V·N-1 at 0.1N), a fast response/recovery time (90/100ms), and environmental stability (20-80°C). MLL-TENG can be applied to human health monitoring and haptic sensing for continuous monitoring of joint flexural amplitude, laryngeal vibration frequency and gait behavior. Based on a quantitative analysis of the range of motion of human joints and the frequency of muscle group movement, a dynamic assessment of the physiological state of the participants can be performed. It provides low-cost detection solutions in scenarios such as the early warning of Parkinson’s disease and real-time monitoring of an athlete’s movement status. Its on-line and noninvasive monitoring capabilities are of great significance in disease prevention, rehabilitation, and healthcare.

CAS / MDL: 1341-49-7
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2025 · IF 13.2

Dual-coupled interfaces drive defect-porosity synergy to enhance low-frequency electromagnetic wave absorption in MXene-based composites

Tong Wu,Penggang Ren,Shoufeng Xue,Lunwu Wang,Zhengzheng Guo,Jiaqi Wang,Ze Zong,Wei Huang,Xin Hou,Fang Ren

Escalating demands for stealth protection and electromagnetic compatibility necessitate electromagnetic wave (EMW) absorbers with high-efficiency broadband attenuation and low-frequency extension, particularly under thin-layer constraints and low filler loading. We propose an integrated interface-pore design strategy for MXene-based absorbers to synchronously co-tune impedance matching and attenuation under thin-layer, low-loading constraints, by integrating dual-coupled heterointerfaces and hierarchical porosity. Specifically, an Fe/Mn bimetallic carboxylate MOF is pyrolyzed in situ to yield solid-solution nano-units embedded in defect-rich carbon. The tightly anchored FeO-MnO nanounits on the surface of delaminated MXene with hydrogen bonding and Ti-O-M (M = Fe/Mn) linkages form dual-coupled crystalline-amorphous-crystalline triphase heterointerfaces, thereby establishing interconnected hierarchical porosity and open transport pathways at nanosheet-particle contacts and within network voids. This interface-pore synergy optimizes the conductive network by maintaining intraflake continuity while tempering excessive conductivity, which broadens the impedance-matching band and strengthens incident-field coupling. Furthermore, the introduced tunable magnetic responses and abundant polarization-active sites effectively compensate for low-frequency loss. At a fixed filler loading of 5 wt%, the composite exhibits a minimum reflection loss (RL min ) of −72.2 dB at 3.38 GHz (S band), indicating excellent low-frequency attenuation. With a thickness of 1.16 mm, it provides an effective absorption bandwidth (EAB) of 4.64 GHz in the X/Ku bands. Furthermore, continuous low-frequency coverage exceeding 5.0 GHz across the S C bands is achieved by adjusting only five matching thicknesses. COMSOL multiphysics simulations demonstrate more uniform energy coupling and continuous volumetric dissipation. RCS calculations predict a main-lobe reduction of ≈ 32.5 dB for a metal-backed panel. This work proposes a transferable route to thin-layer, low-loading, broadband EMW absorption by integrating interface design with hierarchical porosity.

CAS / MDL: 57-09-0 7789-24-4
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Polymer Materials · 2025 · IF 4.7

Rapid Water-Responsive Shape-Memory Nanocellulose/MXene Aerogel for Piezoresistive Sensing and Electromagnetic Interference Shielding in Underwater Environments

Qi Xu,Yuwen Gai,Shuang Wang,Xinmeng Li,Weixiao Ding,Jian Cui,Peng Zhou,Luyu Yang,Lei Zhang,Dongping Sun

In recent years, the development of flexible wearable materials and electromagnetic shielding materials has progressed rapidly. The demand for monitoring movement data and providing protection against electromagnetic waves has also increased significantly. However, there is currently a lack of materials suitable for applications in high-humidity and underwater environments, which limits their ability to meet the needs of users in special conditions. In this study, we designed an aerogel sensor based on MXene and bacterial cellulose (BC) capable of monitoring movement in both dry and wet states while also exhibiting good electromagnetic wave absorption properties.The sensor showed a sensitivity of −6.43 with excellent linearity (99.8%) and stability. The sensor exhibits a high compressive strength of up to 15 kPa in the dry state, with a resistance change rate reaching 50% under 8% strain, and can undergo 710 cycles, demonstrating high sensitivity and stability. Under water-induced conditions, the sensor demonstrates high flexibility, shape-memory performance, and a wide strain range (0–80%) as a wet-state sensor, maintaining good structural stability and sensing performance throughout the dry–wet transition process. The BCNF/MXene sensor also demonstrates good resistance to electromagnetic interference. The RLmin of the BCNF/MXene-30% sensor reaches −45.60 dB, with an electromagnetic wave absorption rate of 99.99% and a relatively broad effective absorption bandwidth (4 GHz). This resistive sensor can be applied in electronic skins, human–machine interactions, smart wearable devices, and personalized health monitoring. Our work successfully demonstrated the application of water-sensitive shape-memory materials in electronic skins, health monitoring components, and electromagnetic wave protection.

CAS / MDL: 2564-83-2 7681-52-9
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES · 2025 · IF 8.5

MXene cracked-layer composite sodium alginate/CNC-based hydrogel for robust sensing with high-sensitivity dynamic motion perception

Fengli Huang,Tong Zhang,Zhiheng Yu,Taiyao Pan,Tianyu Zhang,Hao Xue

Conductive hydrogel strain sensors with high stretchability, wide sensing range and high sensitivity have been extensively studied for their potential applications in wearable sensing devices. However, achieving high sensitivity in the low-strain range remains a challenge. In this study, the hydrogel was prepared by blending acrylamide, sodium alginate, and cellulose nanocrystals. The hydrogel substrate was fabricated using the electrohydrodynamic printing method, and hierarchical ultraviolet photopolymerization was employed to achieve effective bonding between the hydrogel substrate and MXene film. Further, the hydrogel composite substrate was pre-stretched to overcome the interfacial stress differences between the MXene film and hydrogel substrate, thereby completing the fabrication of a PAAM-SA 2% -CNCs 3% & MXene (PSC&M) sensor with the designed crack structure. The fabricated strain sensor significantly broadened the detection sensitivity of hydrogel sensors in the low-strain range (Strain: 0–5 %, GF = 23.4) and achieved fast response/recovery times (106 ms / 82 ms), obtaining excellent mechanical properties (0.33 MPa stress, 710 % elongation at break) and electrical conductivity (1.931 mS/cm). Application demonstrations based on the fabricated PSC&M sensors in various human motions, subtle vibration signal monitoring and hand-knuckle rehabilitation training, to show their potential applications in smart devices, e-skin and wearable medical rehabilitation devices.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Science China-Materials · 2025 · IF 7.4

Centrifugal casting-enabled highly-oriented MXene-based layered films with dual-shielding against electromagnetic wave and infrared radiation

Liu Congqi,Dong Jingyu,Cheng Hongli,He Chengen,Zhou Bing,Huang Ming,Liu Chuntai,Feng Yuezhan

MXene-based layered films show great promise for electromagnetic interference (EMI) shielding, yet maintaining highly ordered structures during large-scale production remains challenging. Herein, we present a facile centrifugal casting method for scalable fabrication of MXene/polyvinyl alcohol (MXene/PVA) films with highly oriented and compact layered structures. During centrifugal casting, the viscous fluid experiences strong shear and centrifugal forces along the tangential and normal directions, respectively, inducing compact and oriented arrangement of MXene nanosheets in the layered structure. Consequently, the Herman’s orientation factor of MXene in composite films shows a significant increase from 0.681 to 0.794 as the rotation rate rises from 0 to 4000 r/min. Accordingly, the tensile strength and toughness of the composite film increase from 55.2 to 191.1 MPa, and from ∼0.8 to 2.5 MJ/m 3 . More importantly, the highly oriented and compact layered structure with the ultrathin thickness (∼8 µm) enables a high absolute electromagnetic shielding effectiveness (SSE/ t ) of 21029 dB cm 2 /g. Moreover, the increased oriented arrangement of MXene in the layered structure can significantly reduce the infrared emissivity to 0.248, thus endowing the MXene/PVA film with excellent thermal camouflage capability. Therefore, this work presents a more effective strategy for constructing high-performance MXene-based layered films.

CAS / MDL: 7789-24-4 9002-89-5
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SEPARATION AND PURIFICATION TECHNOLOGY · 2025 · IF 9

Potato-chip-like two-dimensional magnetic trimetallic oxides derived from MXene-MOF nanocomposites for fast enrichment of phosphopeptides

Sen Zhang,Xingdong Yang,Feng Zhang,Jun-qin Qiao,Wei-juan Zheng,Hong-zhen Lian

Both MXenes and metal-organic frameworks (MOFs) have been attracting lots of attention since being found and have been applied in various fields. Furthermore, MXene-MOF composites have been recently studied to combine the advantages of MXenes and MOFs. However, the synthesis of MXene-MOF composites still suffers from questions such as low-efficiency of exfoliation of MXenes to layered nanosheets, uneven distribution of MOF nanoparticles on MXene nanosheets and extra modification process before the growth of MOF nanoparticles. To resolve these problems, herein, a sonication-assisted minimally intensive layer delamination (SA-MILD) method was proposed to achieve high yield of thin-layer Ti 3 C 2 T x MXene nanosheets. Then, a stirring in-situ growth method (SISG) was carried out to uniformly grow UiO-66–NH 2 nanoparticles on Ti 3 C 2 T x nanosheets to form two-dimensional potato-chip-like Ti 3 C 2 –UiO-66–NH 2 nanocomposites instead of conventional solvothermal method for the first time. Finally, MXene-MOF composites were calcined to increase the chemical stability and endowed with magnetism by the in-situ oxidation growth of Fe 3 O 4 nanoparticles. Thanks to the massively exposed Ti O, Zr O and Fe O sites, the well-characterized magnetic trimetallic oxides (MTMOs) could enrich phosphopeptides by easy magnetic separation through metal oxide affinity chromatography mechanism in a short time. High sensitivity (0.5 nmol∙L −1 of α −/ β -casein) and great anti-interference ability (1:1:2000 of the molar ratio of α −/ β -casein to bovine serum albumin) were realized for the efficient enrichment of phosphopeptides with MTMOs. Non-fat milk and traditional Chinese medicine injections were used as the examples to explore the biomedical applicability of the as-prepared MTMOs with excellent results.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2025 · IF 5.1

Sandwich-type electrochemical immunosensor based on MXene/CNTs substrate and MOFs (MIL-101) probe for leather artifact identification

Lianpeng Lv,Xiaojing Kang,Lubin Hua,Zejian Du,Ruixue Sun,Yefeng Deng,Hailiang Yang,Zheng Xu,Yang Zhou,Bing Wang

Effective identification of excavated leather artifacts assumes a crucial role in the subsequent restoration and protection of the artifacts, and on a deeper level, it holds significant implications for the history and culture represented by the artifacts. Existing approaches fail to address the pain points of micro-trace detection and species identification. In this work, two-dimensional transition metal carbonitrides/carbon nanotubes (MXene/CNTs) and metal organic frameworks (MOFs) were employed as electrochemical immunosensor materials to construct and utilize a sandwich-type immunosensor for the first time to detect leather artifacts. The sensor exhibits a wide linear detection range of 10 −1 –10 3 ng/mL and an extremely low detection limit of 83 pg/mL, which can fulfill the requirements of ultra-sensitive detection. In addition, the sandwich electrochemical immunosensor demonstrates excellent specificity and stability, with the redox peak current value retaining over 95 % of the original value after 10 repeats of cyclic voltammetry (CV) and more than 85 % of the original peak current after one week of differential pulse voltammetry (DPV), with an RSD of 0.767 %. The immunosensor achieves satisfactory outcomes in both qualitative and quantitative detection when analyzing leather artifacts and micro-traces, and its performance surpasses that of existing methods. Therefore, this work not only introduces novel materials for the construction of sandwich immunosensors but also provides new concepts and approaches for archaeological detection of cultural relics.

CAS / MDL: 111-30-8 9013-20-1
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。