Surfaces and Interfaces
·
2022
·
IF 6.137
Lang Wang,Xinyu Wang,Binxin Song,Zhe Wang,Linlin Zhang,Qiongqiong Lu
MnO 2 is a type of ideal cathode material for aqueous zinc-ion batteries (ZIBs) owing to reasonable price, innocuity, and environmental friendliness. Nevertheless, it plagued by the dissolution of manganese ions and poor electrical conductivity . Therefore, designing and fabricating high-performance MnO 2 based cathode materials are essential for the development of ZIBs. In this work, poly(3,4-ethoxylenedioxythiophene) coated MnO 2 (MnO 2 @PEDOT) is in situ fabricated by mixing 3,4-ethoxylenedioxythiophene (EDOT) and KMnO 4 solution to restrain the dissolution of manganese ions, enhance the electronic conductivity and structural stability. As a result, MnO 2 @PEDOT composite possesses superior electrochemical performance . An outstanding capacity of 242 mA h g –1 at 0.2 A g –1 was reached, and eminent long-term stable cycling performance above 1000 cycles with the capacity retentions of 85.1% at 2 A g –1 was achieved. This study demonstrated a facile in situ synthesis strategy of MnO 2 @PEDOT, and it showed a promising potential for practical application.
✓ 已验证
产品关联
DOI
高影响因子
CHEMICAL ENGINEERING JOURNAL
·
2021
·
IF 13.273
Qianqian Liang,Jia Wan,Peng Ji,Dong Zhang,Nan Sheng,Shiyan Chen,Huaping Wang
As the demand for wearable electronic devices persistent to booming, the stretchability of supercapacitors is essential. However, it is still challenging in preparing fiber-based stretchable supercapacitors with the self-stretchable structure instead of relying on an elastic matrix. Here, we constructed a self-stretchable poly(3,4-ethylenedioxythiophene)(PEDOT)@bacterial cellulose(BC)/Carbon nanotube (CNT) hybrid helical fiber with “reinforced cement-sand” structure through wet-spinning and coiling processes by using dissolved BC as bonded matrix, undissolved BC nanofibers and CNT as supporters, PEDOT as reinforcements materials. This structure avoids the disadvantage of relying on the elastic matrix or auxiliary materials to provide elasticity. More importantly, the helical fiber can exhibit the ultimate stretch of 1175%, and the cyclic tests demonstrate the remarkable cycle stability after 100 times of 100% cyclic stretching. Meanwhile, the self-stretchable PEDOT@BC 1 /CNT 2 hybrid helical fiber electrodes show a gravimetric specific capacitance as high as 175.1F/g, which can remain stable under different bending degrees and tensile strains. The energy density and power density of the solid supercapacitor can reach 4.0 Wh/kg and 120.1 W/kg, respectively. This work provides a new strategy of stretchable supercapacitors independent of elastic materials, which will show wide application prospects in wearable electronic products.
✓ 已验证
产品关联
DOI
高影响因子
BIOELECTROCHEMISTRY
·
2020
·
IF 4.722
Jiasheng Wang,Dongwei Wang,Ni Hui
The application of polypeptides in bio-interfaces and biosensors is of great interest because polypeptides are biocompatible and easy to design. A novel polymer nanocomposite was prepared by the electropolymerization of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) with a newly designed polypeptide. The nanocomposite polypeptide doped PEDOT (PEDOT/PEP), with a 3D microporous network structure, large surface area and excellent antifouling ability, was utilized for the attachment of BRCA1 complementary oligonucleotides to construct a DNA biosensor. The fabricated DNA biosensor showed favorable selectivity (with a detection limit of 0.0034 pM) and high sensitivity. The biosensor was also capable of detecting the target DNA (BRCA1) in 1% (V/V) human serum samples. The combination of a conducting polymer PEDOT with an antifouling and biocompatible polypeptide demonstrates a new method for preparing electrochemical sensors, that are capable of detecting targets in complex biological samples without strong nonspecific protein adsorption.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Biomaterials Science
·
2020
·Vol. 8
·期 11
·3173-3185
·
IF 6.183
Boguang Yang,Fanglian Yao,Lei Ye,Tong Hao,Yabin Zhang,Lei Zhang,Dianyu Dong,Wancai Fang,Yan Wang,Xiaoyang Zhang,Changyong Wang,Junjie Li
The development of three-dimensional conductive scaffolds is vital to support the adhesion, proliferation and myocardial differentiation of stem cells in cardiac tissue engineering. Herein, we describe a facile approach for preparing a poly(3,4-ethylenedioxythiophene)/alginate (PEDOT/Alg) porous scaffold with a wide range of desirable properties. In the PEDOT/Alg scaffold, chemically crosslinked alginate networks are formed using adipic acid hydrazide as the crosslinker, and PEDOT is synthesized in situ in the alginate matrix simultaneously. PEDOT exists in the alginate matrix as particles and its morphology can be modulated by adjusting the ratio of PEDOT/alginate. The results also show that the swelling properties, degradation behaviors, mechanical strength and conductivity of the PEDOT/Alg scaffold can be controlled via adjusting the PEDOT/alginate ratio. The introduction of PEDOT can overcome the brittle nature of the pure alginate scaffold. Moreover, the PEDOT/Alg scaffold exhibits excellent conductivity (as high as 6 × 10−2 S cm−1). The introduction of PEDOT improves the protein absorption capacity of the alginate scaffold. To explore its potential application in cardiac tissue engineering, brown adipose-derived stem cells (BADSCs) are seeded in the prepared PEDOT/Alg porous scaffold. The results suggest that the PEDOT/Alg porous scaffold can support the attachment and proliferation of BADSCs. Moreover, it is beneficial for the cardiomyogenic differentiation of BADSCs, especially under electrical stimulation. Overall, we conclude that the PEDOT/Alg porous scaffold may represent an ideal platform to modulate the biological behaviors of BADSCs.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Journal of Materials Chemistry A
·
2015
·Vol. 3
·期 7
·3801-3807
·
IF 7.443
Lianyi Xu,Dandan Zhu,Xuemin Lu,Qinghua Lu
By mimicking nature, the preparation of artificial self-cleaning surfaces has gradually matured both in theory and technology, but their actual application has been hampered by enormous difficulties. The main challenge is that their design principle (i.e., their requirement for micro- and nano-structures) is difficult to reconcile with the need for coating strength and transparency. Here, we have exploited a porous structured silica coating with the help of an electrodeposited porous PEDOT template. This porous silica coating not only provides the requisite roughness for the final superhydrophobic surface, but also has a low refractive index, thereby enhancing the transparency of the silica coating. After fluorination, a highly transparent, thermally and mechanically stable superhydrophobic coating was obtained. The silica coating is found to withstand tests of harsh environments, such as mechanical resistance and ultra-high hydraulic pressure tests. This large-area superhydrophobic coating has great potential for use in solar cells and self-cleaning windows.
研究领域:
材料科学
·
表面工程
·
纳米技术
·
电化学
✓ 已验证
DOI
高影响因子
SENSORS AND ACTUATORS B-CHEMICAL
·
2018
·
IF 5.667
Dandan Fang,Xiangqin Zheng,Huan Yi,Hong Dai,Zhensheng Hong,Yiru Peng,Yanyu Lin
A highly sensitive electrochemiluminescence (ECL) immunosensor was fabricated for the quantitative analysis of deoxynivalenol (DON) based on an effective all-in-one bioprobe that composed of TiO 2 -B with Fluoro-coumarin silicon phthalocyanine (F-couSiPc) and luminol. Herein, TiO 2 -B with large specific area was served as a favorable carrier, greatly increased the loading of enhancer F-couSiPc and luminophore luminol, resulting in the tremendous enhancement of ECL signal. Specifically, F-couSiPc as coreaction accelerator could facilitate the decomposition of dissolved O 2 to generate substantial reactive oxygen species (ROS) to participate in the ECL reaction of luminol. Additionally, the prepared PEDOT/HA@mp MnO 2 was employed as the sensing platform of biosensor, which can not only capture substantial antibody to improve the sensitivity, but also could expedite the electronic transmission rate to make the ECL intensity further amplified. Ultimately, the proposed immunosensor presented favorable performance for the determination of DON, such as high sensitivity, good stability, wide liner range (from 1.0*10 −6 ng/mL to 10 ng/mL) and a low detection limit of 3.3*10 -7 ng/mL.
研究领域:
分析化学
·
食品安全检测
✓ 已验证
DOI
高影响因子
MICROCHEMICAL JOURNAL
·
2025
·
IF 5.1
Ximei Hu,Xiaoqi Chen,Jinlan Li,Jiawei Zhou,Xiaohua Zhu,Meiling Liu,Ying Liu,Youyu Zhang,Yang Liu
Amyloid-beta peptide (Aβ) is considered a promising biomarker for the diagnosis of Alzheimer’s disease (AD). Herein, we developed an anti-fouling photoelectrochemical (PEC) immunosensor for sensitive Aβ40 detection based on Z-scheme heterojunction poly (3,4-ethylenedioxythiophene) (PEDOT)/ZnIn 2 S 4 and zwitterionic peptide. Due to the excellent electrical conductivity of PEDOT, the Z-scheme PEDOT/ZnIn 2 S 4 heterojunction exhibited a high photocurrent response, which can promote the separation and transfer of photogenerated electron/hole pairs. The zwitterionic peptide with hydrophilicity and electrical neutrality was used as a blocking agent to reduce nonspecific adsorption. The proposed PEC immunosensor showed outstanding performance for Aβ40 with high selectivity, stability, wide liner range (from 10 pg mL −1 to 5 ng mL −1 ), and a low detection limit (4.7 pg mL −1 ). Moreover, the integration strategy of heterojunction with zwitterionic peptide provides a promising way for protein detection in practical applications.
研究领域:
生物医学工程
·
分析化学
·
神经退行性疾病研究
✓ 已验证
产品关联
DOI
高影响因子
ACS Applied Materials & Interfaces
·
2025
·
IF 8.2
Qiao Fan,Kai Zhang,Lanlan Wei,Yongji Gong,Shuhao Qin,Min He,Yufei Liu,Tingting Luo,Shigui Peng,Jie Yu
Flexible wearable devices have significant potential for diverse applications, prioritizing the development of portable, safe, and stable dry electrodes. This study focused on designing six poly(sodium styrenesulfonate) (PSS) variants with controlled molecular weights (10k-70k), combined with a water-soluble soft polymer, poly(vinyl alcohol) (PVA), to enhance the electrical properties, mechanical strength, and long-term stability of the Poly(3,4-ethylenedioxythiophene) (PEDOT): PSS polymer complex. We systematically examined morphological modifications, interactions, and conductive processes of PVA/PEDOT: PSS films, along with the mechanisms behind their improved stretchability and resistance stability. Results indicate that low molecular weight PSS provides the best mechanical flexibility due to stronger hydrogen bonding with PVA, enhancing elongation at break. However, insulating domains in PSS and PVA impede carrier transport, leading to a discontinuous charge hopping process along the PEDOT backbone, which decreases electrical conductivity. Conversely, high molecular weight PSS exhibits poor dispersion of rigid segments and conductive materials, resulting in decreased electrical and mechanical properties. Notably, with a molecular weight of 34k, the PVA/PEDOT: PSS film exhibits excellent electrical performance and mechanical flexibility, maintains good resistance stability after 1000 loading and unloading cycles at 30% strain, and demonstrates clear and stable electromyography (EMG) signals, indicating vast potential for EMG electrodes.
研究领域:
材料科学
·
高分子科学
·
生物医学工程
·
柔性电子学
·
可穿戴设备
✓ 已验证
产品关联
DOI
PubMed
高影响因子
BIOELECTROCHEMISTRY
·
2025
·
IF 4.5
Suyun Wei,Jie Zhao,Shaojun Ke,Mingjia Zou,Qingze Han,Guofeng Cui
Highly stable calcium ion selective electrodes (Ca 2+ -ISEs) were developed by drop-casting a layer of poly(3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT: PSS) as an ion-to-electron transfer layer onto Au electrode. The conductive PEDOT: PSS ink was prepared using a metastable liquid–liquid contact (MLLC) doping method, which induced phase separation, removed excess PSS, and significantly enhanced charge transfer kinetics and conductivity. The resulting Ca 2+ -ISEs exhibited excellent electrochemical performance. Potentiometric studies revealed a significant sensitivity of 33.1 ± 0.98 mV/decade (N = 3) with a high potential stability of 3.16 ± 2.53 μV/h. Importantly, Ca 2+ -ISEs combined with the constant potential coulometry method, the lower detection limit was optimized to 8.527 × 10 −8 M (LOD = 3σ/s, N = 3). The performance of the Ca 2+ -ISE system was evaluated in inactivated fetal bovine serum using constant potential coulometry, demonstrating the highest measurement accuracy compared to potentiometric and chronoamperometric. The enhanced PEDOT: PSS-MLLC based Ca 2+ -ISEs combined with the constant potential coulometry method developed in this research demonstrate considerable potential for clinical applications in blood ion analysis.
研究领域:
分析化学
·
生物医学工程
·
临床检验
✓ 已验证
产品关联
DOI
PubMed
高影响因子
DESALINATION
·
2023
·
IF 9.9
Jing Song,Yihan Li,Shihan Wang,Rui Han,Yu Ba,Ying Liu,Shengqiang Fan
Membrane Electro-Bioreactor (MEBR), with dual function of electrochemical in-situ membrane fouling mitigation and pollutants removal by chlorine evolution reaction (CIER), has emerged as a promising technology of treating mariculture wastewater. However, the fouling control mechanism regarding extracellular polymeric substance (EPS) variations and related microbial community is still unclear. In this study, MEBR was developed with conducting anode-membrane modified by CNTs-TiO 2 -PEDOT for fouling resistant and ammonia/nitrite removal. The CIER electroactivity was enhanced that onset potential negatively shifted from 1.12 to 0.98 V vs. SCE (saturated calomel electrode). Ammonia removal rate (71.49 mgN/(L·day)) was 176.8 % higher and nitrite was significantly reduced in MEBR than MBR at HRT of 45 min. Membrane fouling was mitigated in MEBR that operation duration was extended by 40 % compared with MBR. The EPS of cake layer on the membrane surface rather than the biofilters was found the main fouling contributor. The significant reduction in LB-EPSp (65.4 %) in MEBR (33.8 % in MBR) was the dominant factor contributing to membrane fouling alleviation, which highly depended on the relative abundance of Hyphomonas and Hirschia . This study will be beneficial for fouling control in seawater treatment.
✓ 已验证
产品关联
DOI
高影响因子
ENVIRONMENTAL RESEARCH
·
2023
·
IF 8.3
Chibin Zheng,Yunhan Ling,Jianyue Chen,Xiaomin Yuan,Shilin Li,Zhengjun Zhang
Considering the formidable explosive power and human carcinogenicity of nitroaromatic explosives, the implementation of an accurate and sensitive detection technology is imperative for ensuring public safety and monitoring post-blast environmental contamination. In the present work, a versatile and selective electrochemical sensor based on dummy molecularly imprinted poly (3,4-ethylenedioxythiophene)/laser-induced graphene (MIPEDOT/LIG) was successfully developed and the specific detection of multiple nitroaromatic explosives was realized in the single sensor. The accessible and nontoxic trimesic acid (TMA) and superior 3, 4-ethylenedioxythiophene (EDOT) were selected as the dummy-template and the functional monomer , respectively. The interaction between the functional monomer and the template, and the morphology, electrochemical properties and detection performance of the sensor were comprehensively investigated by ultraviolet–visible spectroscopy, Fourier-transform infrared spectroscopy, scanning electron microscopy, cyclic voltammetry, and differential pulse voltammetry. Benefiting from the alliance of TMA and EDOT, the MIPEDOT/LIG sensor manifested outstanding selectivity and sensitivity for 2,4,6-trinitrotolueen (TNT), 2,4,6-trinitrophenol (TNP), 2,4-dinitrotoluene (DNT), 1,3,5-trinitrobenzene (TNB), 2,4-dinitrophenol (DNP), and 1,3-dinitrobenzene (DNB) (representative nitroaromatic explosives) with limits of determination of 1.95 ppb, 3.06 ppb, 2.49 ppb, 1.67 ppb, 1.94 ppb, and 4.56 ppb, respectively. The sensor also exhibited extraordinary reliability and convenience for environmental sample detection. Therefore, a perfect combination of versatility and selectivity in the MIPEDOT/LIG sensor was achieved. The findings of this work provide a new direction for the development of multi-target electrochemical sensors using a versatile dummy template for explosives detection .
✓ 已验证
产品关联
DOI
PubMed
高影响因子
MICROCHEMICAL JOURNAL
·
2023
·
IF 4.8
Qi Guo,Yuhao Zhang,Luting Yan,Xiaoya Meng,Yue Wang,Hongguo Zhai,Xiaofeng Chen,Xia Sun,Yemin Guo,Yanyan Zhang
The use of low-cost working electrodes is of great importance for the development of sensor industrialization. Acupuncture needles electrode (ANE) was selected as working microelectrode, a sensor was designed based on poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT: PSS) and chitosan (CS) modified covalent organic frameworks (COFs) (CS/COFs) for detection of cadmium (Cd(II)). First, a mixture of PEDOT and PSS was electrodeposited on the surface of the acupuncture needles to synthesize a PEDOT: PSS as conductive polymeric film to support the electron transfer capability and enhance the conductive efficiency of the sensor. Then, CS/COFs was self-assembled and attached to the PEDOT: PSS/ANE surface by π-π stacking intermolecular interaction forces and the viscosity of CS, thus increasing the specific surface area of the electrode. Differential pulse anodic stripping voltammetry (DPASV) was used as the electrochemical method for detection of Cd(II). And the results indicated that the CS/COFs/PEDOT: PSS/ANE was linearly responsive in the range of 400 μg/L to 2400 μg/L, and the LOD was 13.8 ng/L for Cd(II). The constructed sensor also showed great selectivity, reproducibility, and stability. Additionally, the sensor demonstrated outstanding recovery in the detection of Cd(II) in real sample scallops. This sensing construction method based on acupuncture needles as working electrodes is of great significance to the development of sensor industrialization and aquatic product safety detection.
✓ 已验证
产品关联
DOI
高影响因子