文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,389+ SCI 论文 与阿拉丁产品引用相关
2,303,681.05 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第2941至2952个,产品总数13,252个

切换升序
AN
TALANTA · 2024 · IF 5.6

Underway mapping of coastal seawater pH using an automated shipboard analyzer with spectrophotometric detection

Hangqian Li,Shu Wang,Shulu Zheng,Tengyue Fang,Huilin Shu,Yi Xu,Xianghui Guo,Eric P. Achterberg,Liyang Zhan,Jian Ma

The development of field-deployable methods and instruments for the measurement of pH and other carbonate parameters is important for the assessment of the marine carbon cycle , ocean acidification and marine carbon dioxide removal techniques. In this study, a high-precision fully automated integrated syringe-pump-based environmental-water analyzer for pH ( i SEA-pH) was developed. The pH is determined spectrophotometrically using purified indicator dye with a high precision (better than ±0.001) and high frequency (3.5 min/sample). For the short-term analysis, the measurement frequency was 18 h −1 , which revealed pH = 7.8148 ± 0.0005 (n = 104) for aged surface seawater (S = 35) from the western Pacific. For long-term analysis, the measurement frequency was 2 h −1 for 4 days, and the results showed that pH = 7.8148 ± 0.0010 (n = 200). Three commonly used pH indicators (meta-cresol purple, thymol blue and phenol red) were purified with improved flash chromatography procedures. The autonomous i SEA-pH can automatically correct for the influence of temperature, salinity and other factors on pH measurements to achieve rapid and accurate on-site measurements, which meet the “climate” goal of the Global Ocean Acidification Observing Network (uncertainty is ±0.003). Three identical i SEA-pH systems were developed and successfully applied in mesocosm experiments and several coastal and open ocean cruises with excellent in field performance.

CAS / MDL: 7758-23-8
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Materials Today Communications · 2024 · IF 3.7

Preparation of tungsten powder by an unmixed carbon reduction method based on carbon diffusion

Yuhui Chen,Zhenhua Hao,Rulong Ma,Pei Wang,Yongchun Shu,Jilin He

In this study, a new unmixed carbon reduction method was proposed for the preparation of pure W powder. The effects of reduction temperature, reduction time, carbon distance and thickness of WO 3 layer on the phase of the reduction products were investigated. Results show that pure tungsten powder with a carbon content of less than 150 ppm can be prepared at 950 °C with a WO 3 layer thickness of 5 mm and a carbon distance of 2 mm. Increased carbon distance and thickness of WO 3 layer will lead to a decrease in the reduction ratio. Additionally, particle size of the tungsten powder gradually increases from 1 μm to 8 μm due to sintering with the extended reduction time. Furthermore, a two-stage carbon reduction process with WO 2 as an intermediate product is proposed, which avoids the sintering and growth of tungsten powder particles and the particle size of tungsten powder was successfully reduced to 2 μm. This unmixed carbon reduction reduces the carbon concentration and prevents the carbonization of tungsten powder. The experiment verifies the feasibility of carbon as a reducing agent in producing pure tungsten powder by reducing WO 3 .

CAS / MDL: 1314-35-8
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Energy Materials · 2025 · IF 5.5

An Organic/Inorganic Hydrogel Composite Artificial Protective Layer Assists High-Performance Zinc Metal Anodes

Wenlong Chen,Xucheng Gu,Xiaoyang Lin,Jiajun Fu,Lin Dai,Sangsang Liu,Ji Liu,Chunsheng Li,Ziqing Gui,Yaru Liang

Although aqueous zinc-ion batteries are considered ideal candidates for grid-scale energy storage systems, their practical applications are still significantly limited by harmful side reactions associated with zinc anodes, particularly dendrite formation and hydrogen evolution. To address these issues, a composite hydrogel interfacial layer SCN(SA/g-C3N4) was developed in this study. This multifunctional hydrogel coating demonstrates exceptional ion-selective properties, effectively preventing direct contact between H2O and the zinc anode while efficiently facilitating Zn2+ transport and nucleation. Additionally, the hydrogel matrix contains a substantial amount of free Zn2+, ensuring efficient and continuous ion replenishment at the electrode–electrolyte interface. Furthermore, g-C3N4 provides numerous zincophilic sites, promoting uniform Zn2+ deposition during cycling. The synergistic effect of this organic–inorganic composite structure endows the zinc anode with remarkable stability during electrochemical cycling. The fabricated SCN@Zn||SCN@Zn symmetric cell maintained stable cycling for 2800 h under the testing condition of 2 mAh cm–2/2 mA cm–2. The SCN@Zn||MnO2 full cell exhibited an 82.3% capacity retention after 1400 cycles at a current density of 2 A g–1. The zinc anode material modified using this method shows practical feasibility for energy storage applications.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED FUNCTIONAL MATERIALS · 2023 ·Vol. 33 ·期 42 ·2304008 · IF 19

Collective Surface Enabling an Ultralong Life of LiCoO2 at High Voltage and Elevated Temperature

Wen Zhang,Fangyuan Cheng,Meng Wang,Jia Xu,Yuyu Li,Shixiong Sun,Yue Xu,Liang Wang,Leimin Xu,Qing Li,Chun Fang,Yuhao Lu,Jiantao Han

Rapidly increasing demand for energy density in consumer electronics is eager for developing high-voltage LiCoO 2 (LCO). However, some great challenges such as severe phase transition and surface instability negate the cycle life of LCO operated at high-voltages (≥4.6 V). Herein, a chemical reconstruction strategy is proposed to form a collective surface of LCO through an interdiffusion reaction of MgHPO 4 ·3H 2 O (MP) so as to extend the cycle life of high-voltage LCO. The collective surface renders a three-layer configuration that demonstrates an amorphous Li 3 PO 4 outmost layer, a spinel-like layer beneath, and a Mg diffusion layer within LCO bulk. MP with relatively low hardness enables the uniform precoating via mechanical mixing, followed by a sintering process to undergo an interdiffusion reaction. Li 3 PO 4 is an intrinsic electrochemical stabilizer against interfacial side reactions. The spinel-like compounds build a high-voltage-stable surface against irreversible O 2 release. In addition, Mg diffuses into the bulk lattice to suppress irreversible phase transition during the deep delithiation of LCO. Therefore, such modified LCO with a collective surface exhibits ultralong life with capacity retention of 82% after 1000 cycles at 1 C within 3.0–4.6 V and stable operating at 4.7 V or elevated temperature (45 °C).

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CELL RESEARCH · 2024 · IF 28.1

The rapid proximity labeling system PhastID identifies ATP6AP1 as an unconventional GEF for Rheb

Feng Ran,Liu Feng,Li Ruofei,Zhou Zhifen,Lin Zhuoheng,Lin Song,Deng Shengcheng,Li Yingying,Nong Baoting,Xia Ying,Li Zhiyi,Zhong Xiaoqin,Yang Shuhan,Wan Gang,Ma Wenbin,Wu Su,Songyang Zhou

Rheb is a small G protein that functions as the direct activator of the mechanistic target of rapamycin complex 1 (mTORC1) to coordinate signaling cascades in response to nutrients and growth factors. Despite extensive studies, the guanine nucleotide exchange factor (GEF) that directly activates Rheb remains unclear, at least in part due to the dynamic and transient nature of protein–protein interactions (PPIs) that are the hallmarks of signal transduction. Here, we report the development of a rapid and robust proximity labeling system named Pyrococcus horikoshii biotin protein ligase ( Ph BPL)-assisted biotin identification (PhastID) and detail the insulin-stimulated changes in Rheb-proximity protein networks that were identified using PhastID. In particular, we found that the lysosomal V-ATPase subunit ATP6AP1 could dynamically interact with Rheb. ATP6AP1 could directly bind to Rheb through its last 12 amino acids and utilizes a tri-aspartate motif in its highly conserved C-tail to enhance Rheb GTP loading. In fact, targeting the ATP6AP1 C-tail could block Rheb activation and inhibit cancer cell proliferation and migration. Our findings highlight the versatility of PhastID in mapping transient PPIs in live cells, reveal ATP6AP1’s role as an unconventional GEF for Rheb, and underscore the importance of ATP6AP1 in integrating mTORC1 activation signals through Rheb, filling in the missing link in Rheb/mTORC1 activation.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED MATERIALS · 2025 · IF 26.8

An Optimized Aerogel-Based Apheresis Device for Targeted Lipid Clearance in Elderly Hyperlipidemia Patients

Hao Zheng,Jiangbangrui Chu,Shikang Li,Xun Tang,Shicheng Bi,Kerong Chen,Anwei Zhou,Youwen Yang,Xinghai Ning,Yurui Xu

Elderly patients with hyperlipidemia often exhibit resistance to conventional hypolipidemic treatments, underscoring the need for more effective strategies to address lipid imbalances in this high-risk group. This study introduces LipClean, an aerogel-based apheresis device specifically designed to remove harmful plasma lipids. LipClean is constructed using hydrophilic cellulose fibers, which serve as a supramolecular platform for synthesizing hydrophobic conjugated polymers through a Sonogashira-Hagihara reaction. These conjugated polymers are then cross-linked with the cellulose fibers via phosphorylation, generating an aerogel monolith with an interpenetrating network of hydrophilic fibers and hydrophobic polymers. Unlike bilayer aerogels that separate hydrophilic and hydrophobic layers, LipClean's interpenetrating structure is precisely engineered through polymer design and gradient cross-linking. This optimization enhances both bodily fluid flow and lipid adsorption while minimizing the removal of essential plasma components and ensuring unobstructed cell passage. In preclinical testing, LipClean significantly reduced triglyceride and cholesterol levels in an elderly rat model of hyperlipidemia and normalized lipid levels in blood samples from hypertensive patients. Importantly, purified blood maintained normal levels of blood cells and physiological and biochemical indicators after apheresis, highlighting LipClean's potential for managing hyperlipidemia-related disorders. This study, therefore, underscores the importance of interdisciplinary collaboration in driving medical device innovation.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Advanced Energy Materials · 2024 ·Vol. 14 ·期 16 ·2303912 · IF 24.4

Boosting the Output of Liquid–Solid Triboelectric Nanogenerator by an External Charge-Pumping Strategy

Peipei Wu,Peng Yang,Zhaoqi Liu,Guangzhao Huang,Xinglin Tao,Siyao Qin,Xuanyi Dong,Li Zheng,Hexing Li,Xiangyu Chen,Zhong Lin Wang

In recent years, liquid–solid triboelectric nanogenerator (LSTENG) has attracted great attention. However, its low average power density and long charging time limit the practical application of this technique. Here, for the first time, a liquid–solid triboelectric nanogenerator combined with external charge-pumping method (ECP-LSTENG) is proposed. Compared to traditional LSTENGs, a charge storage capacitor is added in this ECP-LSTENG to store the output charges from the pumping generator. Then, a charge extraction capacitor is formed by the spreading and shrinking processes of falling droplet, while the charging and discharging process between charge storage and extraction capacitors can generate displacement current output for external circuit. Meanwhile, it is found that a special charged droplets adhesion phenomenon happens at the liquid–solid interface, which seriously hinders the continuous output of ECP-LSTENG. To overcome this limitation, a special coaxial deceleration commutation component is designed to ensure continuous output of the ECP-LSTENG. Finally, the peak power density of a droplet (50 µL) reaches 231.8 W m −2 , surpassing the highest research record to date by 1.43 times. This ECP-LSTENG provides a different approach for the future development of large-scale integrated raindrop generators for efficient raindrop energy harvesting.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Food Analytical Methods · 2025 · IF 3

Novel Silicon-Based Carbon Quantum Dots: An Efficient Fluorescent Probe for Precise Tryptophan Detection

Hu Jianan,Hong Dilong,Zhang Huan,Jiang Yuliang

Tryptophan, an essential amino acid for the human body, plays a crucial role in various physiological processes, including protein synthesis, fatty acid metabolism, enhancing energy levels, and being converted into neurotransmitters to regulate sleep and mood. It is also used in the prevention and treatment of pellagra. However, excessive intake of tryptophan can cause adverse effects, so detecting its concentration is of great significance. In this paper a silicon-based carbon quantum dot (N,Si-CDs) tryptophan probe was prepared. The structure and composition of N,Si-CDs were characterized by TEM, FT-IR, and XPS. Fluorescence studies revealed that N,Si-CDs exhibited high selectivity for tryptophan with minimal interference from other substances. There was a good Linear relationship between the fluorescence intensity of N,Si-CDs and the concentration of tryptophan in the range of 5–25 μM, and the detection Limit was as low as 19 nM. N,Si-CDs were successfully applied to detect tryptophan in complex Matrices such as honey, Yili milk powder, water-soluble vitamin C, sour plum soup, and lemon tea, with recovery rates ranging from 81.3% to 106.4%. Cell experiments demonstrated that N,Si-CDs had low toxicity to T24 cells and could be used for live-cell imaging. This N,Si-CDs shows great potential in fields such as food safety, environmental monitoring, and biomedical research.

CAS / MDL: 875-74-1
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED FUNCTIONAL MATERIALS · 2025 · IF 19

An Integrated Paper-Based Patch for Wearable Detection of Diabetic Nephropathy Biomarkers in Sweat

Shanshan Zhang,Hongfeng Wang,Yuke Zheng,Yelan Yao,Tianyu Li,Yukun Ma,Yue Zhou,Zhiyang Chen,Yiming Wei,Lu Fang,Xiangmei Chen,Xuesong Ye,Jianhui Zhou,Bo Liang

The global epidemic of diabetes has popularized at-home glucose monitoring. However, detecting biomarkers for serious diabetes complications, such as diabetic nephropathy (DN), still necessitates frequent hospital visits, invasive blood analyses, and bulky laboratory equipment. Herein, a wireless wearable device based on an integrated paper-based patch (IPP) for non-invasive monitoring of three key DN biomarkers: glucose, creatinine, and uric acid, via in situ sweat analysis, is demonstrated. The disposable IPP realizes the all-in-one preparation of a high-performance electrochemical sensor array, an efficient microfluidic module, and iontophoresis electrodes, enabling reliable multi-parametric on-body sweat monitoring at rest. Notably, all electrodes on the IPP are treated with acrylamide-doped PEDOT: PSS conductive ink, imparting high conductivity to the IPP while preserving the porous structure of the paper substrate, thereby maximizing the electrochemically active area for highly sensitive detection of biomarkers. The usability of the wearable device is validated in assessing metabolic status in healthy participants after dietary intake and during physical exercise, as well as dialysis efficacy during hemodialysis in patients with end-stage renal disease. The wearable device for detecting DN biomarkers in sweat may facilitate at-home disease monitoring and the real-time assessment of hemodialysis efficacy for DN patients.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED FUNCTIONAL MATERIALS · 2025 · IF 19

An Ultrasound-Responsive Hydrogel for Diabetic Wound Electrotherapy Based on Interfacial Ion/Electron Transfer

Fang Wang,Shiwei Guan,Shuhan Chen,Jiajun Qiu,Xuanyong Liu

Chronic diabetic wounds persist as a clinical healthcare challenge. In the hyperglycemic pathological milieu, excessive inflammation, peripheral neuropathy, and vascular disorders impede diabetic wound healing. Immunoregulation is substantially emphasized among these factors; however, research on neurovascular regeneration remains insufficient. Endogenous electric fields (EFs) can regulate cellular behaviors and significantly impact the wound healing process. Herein, a conductive composite hydrogel (CGGP) with ultrasound-responsive electrical stimulation based on interfacial ion/electron transfer for diabetic wound electrotherapy is proposed. CGGP is synthesized through physicochemical crosslinking of gelatin and polyvinyl alcohol (PVA) dual networks and incorporated with curcumin-loaded reduced graphene oxide (rGO). The conductivity of CGGP is comparable to that of skin. Notably, CGGP can generate electrical stimulation based on ion transfer at the fluid–solid interface (electrokinetic effects) and electron transfer at the curcumin-rGO interface in response to ultrasound. Moreover, CGGP exhibits an ultrasound-responsive release of curcumin for anti-inflammatory treatment. The ultrasound-responsive CGGP can promote the secretion of neurotrophic factors, vessel formation, and fibroblast migration. Furthermore, it facilitates local nerve regeneration, angiogenesis, and matrix remodeling in diabetic rat models, thereby accelerating diabetic wound healing. The sonoelectrical CGGP composite hydrogel holds great potential as a promising material for diabetic wound treatment.

CAS / MDL: 50-81-7 56-40-6
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED FUNCTIONAL MATERIALS · 2025 · IF 19

An AB-Type Hydrogel CT Contrast Agent for Precise Localization of Intra-Abdominal Hemorrhage

Kanghua Zeng,Bohong Chen,Qifan Liu,Zheng Zhou,Xiahong Xie,Xiangna Zhang,Xiang Li,Xiuping Zhang,Ben Ma,Mingzhou Ye

Intra-abdominal hemorrhage is a life-threatening condition with high mortality. Rapid localization of the bleeding point is crucial. Conventional computed tomography (CT) imaging is limited by the rapid diffusion and poor retention of small-molecule iodine agents, restricting sensitivity and imaging duration. To overcome these challenges, an “AB-type” hydrogel CT contrast system is developed based on bio-orthogonal click chemistry, designed to enhance both detection sensitivity and spatial precision. The system consists of iodized oil-loaded liposomal nanoparticles (INb NPs) administered intravenously and tetrazine-functionalized hyaluronic acid (HA-Tz) delivered intraperitoneally. At the bleeding site, the two components undergo a rapid click reaction, forming an in situ hydrogel that anchors the contrast agent for prolonged retention and precise localization. This approach demonstrated efficient gelation in vitro and robust performance in vivo, significantly extending the imaging window and sensitivity compared with Iohexol. HA-Tz@INb NPs enhance CT signal intensity and imaging duration by over 60 fold, enabling sensitive detection of occult bleeding. The hydrogel exhibits excellent biosafety, being removable by lavage and fully degradable within days without adverse effects. By integrating nanotechnology, click chemistry, and hydrogel engineering, this strategy provides a clinically translatable diagnostic platform with superior precision and sensitivity for intra-abdominal bleeding.

CAS / MDL: 362596-00-7
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED FUNCTIONAL MATERIALS · 2021 ·Vol. 31 ·期 43 ·2103255 · IF 18.808

An Integrated Luminescent Information Encryption–Decryption and Anticounterfeiting Chip Based on Laser Induced Graphene

Congcong Zhu,Lu-Qi Tao,Zhirong Peng,Guanya Wang,Yexiong Huang,Simin Zou,Hao Sun,Yunfei Zhao,Xianping Chen,Tian-Ling Ren

Visual optical information encryption–decryption and anti-counterfeiting (IEDAC) technology play a vital role in the field of information security. Recent luminescent information encryption technologies face the disadvantages of depending on external large-scale stimulus decryption equipment, inability to read out repeatedly, and information leakage, impeding the practical applications of luminescence encryption. Here, an integrated luminescent IEDAC chip is proposed, which provides a convenient approach to store and decipher pre-patterned luminescence information based on laser engraved template and film heater. The luminescent encryption chip contains a double-layer structure made up of long persistent phosphors based on SrCaGa 4 O 8 host and a laser induced graphene heater, which makes it possible to decrypt information on a single chip. This design enables dual-mode (photoluminescence/long persistent luminescence), dual-color (blue/yellow-green), and multi-level IEDAC function, providing a novel insight and integrated strategy for implementing advanced IEDAC technologies.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。