LC/MS/MS
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES · 2025 · IF 2.8

Development and validation of an LC-MS/MS method for simultaneous determination of XZP-3287(bireociclib) and its metabolites in human plasma, and its clinical pharmacokinetics application

Bohan Liang,Yanjie Li,Lingmei Xu,Li Wang,Quankun Zhuang,Shiqi Dong,Huirong Fan

XZP-3287(bireociclib) is a novel and selective inhibitor of the cell cyclin-dependent kinases 4/6 (CDK4/6), which is primarily employed for the treatment of breast cancer in clinical trials . In this study, a novel and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of XZP-3287 and its metabolites XZP-5286, XZP-3584 and XZP-5736 in human plasma in accordance with international conference on harmonization of technical requirements for registration of Pharmaceuticals for Human use (ICH) guideline R3 (M10) guideline. The multiple reaction monitoring mode (MRM) of mass spectrometer was used and all compounds were monitored in electrospray ionization (ESI+) mode. The correlation coefficients (R 2 ) of all calibration curves for linear regression were greater than 0.99. The intra- and inter-day precision of XZP-3287 and its metabolites XZP-5286, XZP-3584 and XZP-5736 were determined to be 5.2 %–5.5 %, 14.9 %–10.1 %, 6.9 %–13.8 % and 7.3 %–5.6 %, and their accuracy were determined to be 5.2 %–6.0 % 6.9 %–4.4 %, 11.1 %–5.0 % and 7.4 %–5.6 %, respectively. In conclusion, a method for the simultaneous detection of the pharmacokinetic profiles of XZP-3287 and its metabolites in human plasma had been successfully developed. The results demonstrated the efficacy, sensitivity, and reliability of this method

CAS / MDL: 64-18-6
研究领域: 药物分析 · 临床药理学 · 肿瘤学 · 质谱分析 · 药物代谢 · 生物分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF MASS SPECTROMETRY · 2026 ·Vol. 61 ·期 8 ·e70088 · IF 2.1

A Metrologically Traceable Candidate Reference Measurement Procedure (cRMP) for Dehydroepiandrosterone Sulfate in Human Serum Based on Isotope Dilution-Liquid Chromatography–Tandem Mass Spectrometry (ID-LC–MS/MS)

Liping Yang,Bingling Gao,Tao Yang,Liping Tang,Ying Kan,Keqi Sun,Peng Xiao

Dehydroepiandrosterone sulfate (DHEAS), a crucial steroid hormone for adrenal function and pubertal development, is highly associated with related diseases. This study aims to develop and validate an isotope dilution liquid chromatography tandem mass spectrometry (ID-LC–MS/MS)-based candidate reference measurement procedure (cRMP) for quantifying serum DHEAS. Serum samples were prepared by protein precipitation with acetonitrile and separated on a reversed phase column. Assay validation was conducted under the guidance of standard documents, including C62-A, EP6-A, EP10-A3, and C50-P endorsed by the Clinical and Laboratory Standards Institute (CLSI). The cRMP was established and proven to be highly specific without significant matrix effect and able to accurately quantify DHEAS in human serum. The intra-assay and inter-assay imprecision ranged from < 0.1 to 1.0% and from 1.0 to 1.1%, respectively. Trueness was assessed by recovery rate from 99.6 to 101.2%. The limit of detection (LoD) was 0.270 nmol/L, and the lower limit of the measuring interval (LLMI) was 12.1 nmol/L. A linear correlation ranged from 7.60 to 41 858 nmol/L was observed with a correlation coefficient > 0.999. R 2 value of linear regression analysis between this method and clinical immunoassays was ≥ 0.990. The relative expanded uncertainty was 1.5%–2.5% over the concentration range of 12.1–33 043 nmol/L. This study developed an ID-LC–MS/MS-based cRMP, which provided high specificity, trueness, and precision for serum DHEAS quantification, contributing to the DHEAS measurement standardization and traceability.

CAS / MDL: 438-67-5 53-41-8 50-02-2
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL AND BIOANALYTICAL CHEMISTRY · 2026 · IF 4.1

An ionic liquid-functionalized styrene-maleic anhydride copolymer brush stationary phase coupled with offline two-dimensional LC-MS/MS for comprehensive exosomal phospholipid profiling in breast cancer

Guan Xinhui,Zhang Yuying,Ma Xiaoqiao,Wang Haiyan,Qiao Xiaoqiang,Gu Xiaofei

Comprehensive characterization of exosomal phospholipids is essential for understanding cancer-associated metabolic alterations and discovering potential biomarkers, but remains challenging due to their extensive structural diversity and the limited selectivity and coverage of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) approaches. In this study, an ionic liquid-functionalized styrene-maleic anhydride copolymer brush stationary phase (Sil-BHHICl) was developed and integrated into an offline two-dimensional (2D) LC-MS/MS platform for comprehensive exosomal phospholipid profiling. The Sil-BHHICl stationary phase exhibited a hydrophilic interaction/reversed-phase mixed-mode retention mechanism and provided enhanced selectivity toward phospholipids, enabling efficient separation at both the phospholipid-class and molecular-species levels. The developed analytical platform enabled comprehensive profiling of plasma-derived exosomal phospholipids, resulting in the identification of 274 molecular species belonging to 10 phospholipid classes. Lipidomic analysis of plasma exosomes from breast cancer patients and healthy controls revealed distinct phospholipid alterations associated with breast cancer and identified five candidate biomarkers, among which LysoPC-O (16:0) exhibited the strongest discriminatory ability. Pathway enrichment analysis further indicated that the altered phospholipids were predominantly associated with glycerophospholipid metabolism, suggesting extensive lipid metabolic remodeling in breast cancer. Overall, this study establishes a mixed-mode chromatographic platform for high-coverage exosomal phospholipid profiling and demonstrates its potential for lipidomics-based biomarker discovery and investigation of disease-associated metabolic alterations. Graphical abstract

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CLINICA CHIMICA ACTA · 2026 · IF 4.1

High-throughput quantification of tacrolimus in whole blood by acoustic ejection mass spectrometry: analytical validation and comparative assessment against conventional LC-MS/MS for therapeutic drug monitoring

Xin-Yu Wu,Xiao-Kang Fu,Ao Li,Wei Zhang,Han-Peng Jiang,Na An,Quan-Fei Zhu,Shao-Ting Wang,Yu-Qi Feng

Background Therapeutic drug monitoring (TDM) of tacrolimus requires accurate, high-throughput methods, but conventional liquid chromatography–tandem mass spectrometry (LC-MS/MS) is limited by lengthy run times and complex sample preparation. Methods We developed a chromatography-free assay for quantification of tacrolimus in whole blood by integrating cold-induced phase separation with acoustic ejection mass spectrometry (AEMS). This workflow only requires less than 10 μL of whole blood, eliminates centrifugation, and enables direct nanoliter-scale injection into the mass spectrometer. The AEMS assay performance was validated in accordance with CLSI C62-A and ICH M10 guidelines using 62 patient samples and matrix-matched calibrators, demonstrating its suitability for high-throughput therapeutic drug monitoring. Results The AEMS assay exhibited excellent linearity (0.5–50 μg/L; R 2  = 0.9987), with a lower limit of quantification of 0.5 μg/L, which was well below clinically relevant trough concentrations. Accuracy (93.3%–100.1%) and precision (intra-day RSD: 3.7%–11.3%; inter-day RSD: 2.3%–12.4%) met regulatory acceptance criteria. Results showed strong concordance with routine LC-MS/MS (Spearman ρ = 0.972; Passing–Bablok slope = 1.100 [95% CI: 1.026–1.177]). The total analysis cycle time was less than 3 s per sample, enabling a throughput exceeding 1000 samples per hour theoretically. Conclusion This study establishes the first chromatography-free mass spectrometry platform validated for clinical TDM of TAC. By integrating ultra-high throughput capability, minimal sample consumption, and robust analytical performance, the AEMS workflow offers a transformative analytical solution for high-demand clinical environments, including transplant centers and pediatric monitoring settings.

CAS / MDL: 64-18-6
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHROMATOGRAPHIC SCIENCE · 2025 ·Vol. 63 ·期 10 · IF 1.3

Development and Validation of a Sensitive LC–MS/MS Method for Determination of Deoxythioguanosine in Human DNA and its Application in Thiopurine-Treated Inflammatory Bowel Disease Patients

Zheng Jun-tao,Kong Jia-he,Yang Ting,Wang Xue-ding,Guan Shao-xing,Guan Yan-ping,Huang Min,Gao Xiang,Chao Kang,Zhu Xia

Deoxythioguanosine (dTG), incorporated into DNA as DNA-TG, is considered a more relevant thiopurine metabolite than erythrocyte thioguanine nucleotides, as erythrocytes are not the drug target. We established a simple and sensitive liquid chromatography–tandem mass spectrometry method to detect dTG in human blood nucleated cell DNA and validated its clinical applicability in Chinese patients with inflammatory bowel disease to improve individualized thiopurine treatment. dTG was released from 1 μg DNA in a single hydrolysis step, separated by the X-Terra RP18 column and quantified by tandem mass spectrometry with 2′- Deoxyguanosine-13C,15N2 as the internal standard. The calibration curve covered eight concentration levels (0.125–25 ng/mL) with the correlation coefficients r2 ≥ 0.99. The intra- and inter-assay variability was achieved less than 9.9%. This method was employed in a study where a total of 125 inflammatory bowel disease patients with a median DNA-TG level of 279.7 fmol/μg DNA (interquartile range 183.5 ~ 410.6 fmol/μg DNA). Nucleoside diphosphate-linked moiety X-type motif 15 variant carriers (*2, *3, *5, *6) showed significantly higher DNA-TG/dose and DNA-TG/erythrocyte thioguanine nucleotides ratios than wild-type patients (P = 0.0023, P = 0.0001). In summary, this method was simple and stable to detect dTG in DNA, which may act as a promising biomarker predicting the toxicity and efficacy in patients treated with thiopurine.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2025 · IF 5.1

A new method based on a commercial molecular sieve for the determination of bioamines in fruit wines by dispersive solid phase microextraction coupled to LC-MS/MS

Lingcan Kong,Haixin Chen,Qiaoyan Liu

Excessive intake bioamines is harmful to human health, and thus the development of simple, rapid and efficient detection method of bioamines in food is urgent. Herein, an unprecedented method based on a commercial molecular sieve has been developed for the determination of four bioamines (cadaverine, tyramine, histamine and tryptamine) in fruit wines by dispersive solid phase microextraction (D-μSPE) coupled to liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS). The extraction process of ultra-stable Y-type molecular sieve (USY) on bioamines belongs to physisorption, and the adsorption pattern is found in good accord with the Langmuir isotherm model. Theoretical and experimental analyses are further used to explore their binding energies, binding constants, and the maximum adsorption capacity. It is found that the adsorption is driven mainly by hydrogen bonds between USY and bioamines and water molecules. Moreover, the extraction efficiency is dependent on the binding constants and the maximum adsorption capacity of USY. The optimization of adsorption-desorption process involves the USY amount, extraction time, desorption solvent, desorption time, desorption number and cyclic usage number of USY. Under the optimum conditions, the limits of detection and quantification were found in the range of 0.2–2.5 μg L −1 and 0.6–8 μg L −1 with intra-day and inter-day precision and recoveries in a fruit wine in the range of 1.3 %–7.9 % and 91 %–104 %, respectively. Owing to the efficient enrichment and edulcoration functions of USY, the method shows negligible matrix effect and is simple, rapid, and has the potential to apply in routine work.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CLINICAL BIOCHEMISTRY · 2025 · IF 2.1

Reliable LC-MS/MS method development and validation for the determination of methylmalonic acid, methylcitric acid, malonic acid, ethylmalonic acid, and total homocysteine in dried blood spots

Chunyan Zhang,Nan Bai,Yanling Yang,Yuxuan Cheng,Xiyu He,Meng Wang,Honghui Zhou,Yaping Tian

Objectives Metabolic disorders in newborns can cause significant morbidity and mortality if not diagnosed and managed early. In this study, we developed and validated a reliable LC-MS/MS method to simultaneously quantify methylmalonic acid, methylcitric acid, malonic acid, ethylmalonic acid, and total homocysteine associated with metabolic disorders. Design and methods According to Clinical Laboratory Standards Institute (CLSI) guidelines, various analytical performances (i.e., precision, linearity, accuracy and reference intervals) were rigorously evaluated. Meanwhile, sample preparation, chromatographic separation and mass spectrometric detection and incorporating stable isotope-labeled internal standards were optimized. Furthermore, calibrators and quality controls were developed to ensure standardization and traceability. Results The coefficient of variations for precision were less than 10.0 %. Meanwhile, the results showed high accuracy (recoveries: 94.57 %–109.60 %) and robust linearity (R 2  > 0.9935) over clinically relevant ranges. The limits of detection and limits of quantification for all analytes were established, enabling sensitive detection of pathological elevations. Reference intervals for pediatric populations (ages 0–1 month and 2 months to 18 years) were determined, providing essential baselines for clinical interpretation. Conclusions The newly developed method demonstrated good analytical performance and offers a standardized, high-throughput solution for clinical laboratories to improve early diagnosis and personalized management of metabolic diseases.

CAS / MDL: 71-36-3 7647-01-0
研究领域: 临床化学 · 代谢组学 · 新生儿筛查 · 质谱分析 · 生物医学检验
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES · 2024 · IF 2.8

Simultaneous determination of three tyrosine kinase inhibitors and three triazoles in human plasma by LC-MS/MS: applications to therapeutic drug monitoring and drug-drug interaction studies

Ninghong Li,Lu Liu,Dong Liu,Hengyi Yu,Guangjie Yang,Lihui Qiu,Yufei Chen,Dong Xiang,Xuepeng Gong

Tyrosine kinase inhibitors (TKIs) and triazole antifungals are the first-line drugs for treating chronic myeloid leukemia (CML) and fungal infections, respectively, but both suffer from large exposure differences and narrow therapeutic windows. Moreover, these two types of drugs are commonly used together in CML patients with fungal infections. Multiple studies and guidelines have suggested the importance of therapeutic drug monitoring (TDM) of TKIs and triazoles. Currently, methods for the simultaneous determination of both types of drugs are limited. We developed a simple, rapid, and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of three commonly used TKIs (imatinib, dasatinib, and nilotinib) and three commonly used triazoles (voriconazole, itraconazole, and posaconazole) in human plasma. The analytes were eluted on a Welch XB-C 18 analytical column (50 × 2.1 mm, 5 µm) at 0.7 mL/min, using a gradient elution of 10 mM ammonium formate (A) and methanol–acetonitrile-isopropanol (80:10:10, v / v / v ) containing 0.2 % formic acid (B) with a total analysis time of 3.5 min. The calibration curves were linear over the range from 20 to 4000 ng/mL for imatinib and nilotinib, from 2 to 400 ng/mL for dasatinib, and from 50 to 10,000 ng/mL for voriconazole, itraconazole, and posaconazole. Selectivity, accuracy, precision, recovery, matrix effect, and stability all met the validation requirements. The method was successfully used for TDM in CML patients who co-treated with both TKIs and triazoles. Drug-drug interaction analysis between TKIs and triazoles showed that a significant positive correlation was observed between imatinib and voriconazole, as well as dasatinib and voriconazole. Therefore, this method can be well applied in clinical TDM for patients receiving TKIs, triazoles, or both simultaneously.

研究领域: 临床药理学 · 分析化学 · 血液病学 · 感染病学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
TALANTA · 2024 · IF 5.6

LC-MS/MS method for dual-ligand peptide-drug CBP-1018 and its deconjugated payload MMAE including sample stabilization strategy for its MC-Val-Cit-PABC linker

Xianjing Li,Minlu Cheng,Yiya Wang,Chang Shu,Bingjie Zou,Qinxin Song,Li Ding

Recently, peptide-drug conjugate (PDC) has become the most promising conjugated drug for tumor therapy after antibody-drug conjugate due to stronger tumor penetration capacity and lower immunogenicity . CBP-1018 was a PDC with dual-ligand conjugated to MMAE via a cleavable linker (MC-Val-Cit-PABC) that can be lysed by cathepsins B. In this study, two specific LC-MS/MS methods were developed and validated for the determination of CBP-1018 and its metabolite MMAE in human plasma. To prevent the cleavable MC-Val-Cit-PABC linker from degradation, a protease inhibitor (cOmplete solution) was added to the pre-cooled vacuum tubes and the separated plasma samples. The assays involved the pretreatment of CBP-1018 by protein precipitation with H 2 O-ACN (1:9, v / v ) and the extraction of MMAE by liquid-liquid extraction with ethyl acetate under alkaline condition to eliminate the interference of CBP-1018 on MMAE. The two analytes showed good linearities over the calibration ranges (R 2  ≥ 9980). Both accuracy and precision met the acceptance criteria. The validated methods were successfully applied to the phase I dose-escalation study of CBP-1018 injection in Chinese patients with solid tumors to evaluate the pharmacokinetic properties of CBP-1018 and MMAE. The results showed that CBP-1018 was eliminated immediately after injection and MMAE reached the maximum exposure at approximately 2 h after infusion. The maximum concentration of MMAE did not exceed 20.0 ng/mL, suggesting that the off-target toxicity of CBP-1018 injection was controllable.

CAS / MDL: 64-18-6
研究领域: 药理学 · 肿瘤学 · 分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOMEDICAL CHROMATOGRAPHY · 2017 ·Vol. 32 ·期 4 ·e4156 · IF 1.613

Simultaneous determination of tryptophan, kynurenine, kynurenic acid, xanthurenic acid and 5-hydroxytryptamine in human plasma by LC-MS/MS and its application to acute myocardial infarction monitoring

Qing Tong,Jia Song,Guangjie Yang,Li Fan,Wei Xiong,Jianguo Fang

Reliable methods for the determination of tryptophan and its metabolites are vital to the monitoring of biochemical states during the initiation and progression of cardiovascular disease. In the present study, a single-run liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of tryptophan (Trp) and its metabolites, including kynurenine (Kyn), kynurenic acid (KA), xanthurenic acid (XA) and 5-hydroxytryptamine (5-HT), in human plasma. The plasma samples were prepared using a protein precipitation approach, and the chromatographic separation was performed by gradient elution on a C 18 column within a total analysis time of 3.5 min. The calibration ranges were 40–20,000 ng/mL for Trp, 4–2000 ng/mL for Kyn, 0.2–100 ng/mL for KA, 0.4–200 ng/mL for XA and 1–500 ng/mL for 5-HT, and the precision and accuracy were acceptable. The evaluation of recovery and internal standard-normalized matrix effect proved that the sample preparation approach was effective and the matrix effect could be negligible. The newly developed method was successfully applied to the analysis of plasma samples from healthy individuals and myocardial infarction patients. The findings suggested that the plasma concentrations of Trp, Kyn, 5-HT as well as the concentration ratios of Kyn/Trp and Trp/5-HT might serve as biomarkers for the monitoring of acute myocardial infarction.

研究领域: 临床化学 · 心血管疾病 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Frontiers in Veterinary Science · 2023 · IF 3.2

Development and validation of an LC–MS/MS method for the simultaneous quantification of milbemycin oxime and praziquantel in plasma: application to a pharmacokinetic study in cats

Shiting Xie,Yixing Lu,Jun Wang,Changcheng Lin,Peiyu Ye,Xiaolin Liu,Wenguang Xiong,Zhenling Zeng,Dongping Zeng

Introduction Milbemycin oxime (MBO) and praziquantel (PZQ) have a broad spectrum of biological activity and are commonly used to treat the parasitic infection in the veterinary clinic. In this study, a fast and efficient LC-MS/MS method was established and validated for the simultaneous determination of MBO, PZQ, cis-4-hydroxylated-PZQ (C-4-OH-PZQ) and trans-4-hydroxylated-PZQ (T-4-OH-PZQ) and in cat plasma. Methods Extraction of analytes and internal standards from cat plasma by acetonitrile protein precipitation, allows rapid processing of large batches of samples. MBO, PZQ, C-4-OH-PZQ, T-4-OH-PZQ, and internal standard (IS) were eluted for 13.5 min on a C 18 column with a 0.1% formic acid water/acetonitrile mixture as the mobile phase. Results Results showed that the method had good precision, accuracy, recovery, and linearity. The linearity range was 2.5–250 ng/mL for MBO, and 10–1000 ng/mL for PZQ, C-4-OH-PZQ, and T-4-OH-PZQ. The intra-day and inter-day precision CV values of the tested components were within 15%. The extraction recoveries of the four components ranged from 98.09% to 107.46%. The analytes in plasma remained stable for 6 h at room temperature, 26 h in the autosampler (4 °C), after freeze–thaw (−20°C) cycles, and 60 days in a −20°C freezer. Method sensitivity sufficed for assessing pharmacokinetic parameters of MBO, PZQ, C-4-OH-PZQ, and T-4-OH-PZQ in plasma samples with LLOQ of 2.5 ng/mL for MBO and 10 ng/mL for PZQ, C-4-OH-PZQ, and T-4-OH-PZQ. Conclusion In this study, a selective and sensitive LC-MS/MS method for the simultaneous quantification of MBO, PZQ, C-4-OH-PZQ, and T-4-OH-PZQ in cat plasma was developed and validated.This method had been successfully applied to evaluate the pharmacokinetics of MBO, PZQ, C-4-OH-PZQ, and T-4-OH-PZQ after a single oral administration of 8 mg MBO and 20 mg PZQ in cats.

CAS / MDL: 64-18-6
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Frontiers in Chemistry · 2019 · IF 3.782

Simultaneous Determination of Selegiline, Desmethylselegiline, R/S-methamphetamine, and R/S-amphetamine on Dried Urine Spots by LC/MS/MS: Application to a Pharmacokinetic Study in Urine

Chen Lizhu,Yu Yingjia,Duan Gengli,Wang Xin,Shen Baohua,Xiang Ping

Objective: Chiral analysis is a crucial method to differentiate selegiline intake from drug abuse. A dried urine spot (DUS) analytical method based on spotting urine samples (10 μL) onto dried spot collection cards, and followed by air-drying and extraction, was developed and validated for the determination of selegiline, desmethylselegiline, R/S-methamphetamine, and R/S-amphetamine.Methods: Methanol (0.5 mL) was found to be the ideal extraction solvent for target extraction from DUSs under orbital-horizontal stirring on a lateral shaker at 1,450 rpm for 30 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions using multiple reaction monitoring mode. The chromatographic system consisted of a ChirobioticTM V2 column (2.1 × 250 mm, 5 μm) and a mobile phase of methanol containing 0.1% (v/v) glacial acetic acid and 0.02% (v/v) ammonium hydroxide.Results and conclusions: The calibration curves were linear from 50 to 5,000 ng/mL, with r > 0.995 for all analytes, imprecisions ≤ 15% and accuracies between −11.4 and 11.7%. Extraction recoveries ranged from 48.6 to 105.4% with coefficients of variation (CV) ≤ 13.7%, and matrix effects ranged from 45.4 to 104.1% with CV ≤ 10.3%. The lower limit of quantification was 50 ng/mL for each analyte. The present method is simple, rapid (accomplished in 12 min), sensitive, and validated by a pharmacokinetic study in human urine collected after a single oral administration of SG.

CAS / MDL: 1336-21-6
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed