文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,389+ SCI 论文 与阿拉丁产品引用相关
2,303,681.05 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第3049至3060个,产品总数5,480个

切换升序
3'
Science China-Technological Sciences · 2026 ·Vol. 69 ·期 5 ·1500114 · IF 5.1

Highly sensitive liquid metal/thermoplastic polyurethane composite porous fiber-based strain and pressure sensor

Tang Jiabo,Zou Yang,Lyu Yonggang

Fiber-based sensors have garnered significant attention due to their potential applications in various fields. However, conventional fiber-based sensors often exhibit limited sensitivity and integration capabilities. In this study, a liquid metal (LM)/thermoplastic polyurethane (TPU) composite porous fiber-based strain and pressure sensor (LTPFS) was designed for fabricating strain and pressure-sensing fabrics. The LTPFS consisted of an LM/TPU sheath and LM conductive core. The LM/TPU sheath was fabricated using a coaxial wet spinning technique. In the pressure range of 0–70 kPa, the sensitivity of LTPFS with 50 wt% of LM added in the fiber sheath was increased by (4.41 ± 1.39) times compared to the sensitivity of fibers without LM. The LTPFS’s strain gauge factors were 9.08 ± 8.98, 33.62 ± 25.79, 82.40 ± 59.97, and 237.78 ± 189.61 in the range of 0%–50%, 50%–100%, 100%–200%, and 200%–300% strain. The LTPFS demonstrated exceptional performance characteristics, including rapid response and recovery time, good operational stability, and superior cyclic durability in both strain and pressure sensing applications. The fabrics fabricated by LTPFS had a good ability to monitor human body motion and detect pressure distribution. The methodological innovations presented in this study establish a robust foundation for the development of next-generation fiber sensors.

CAS / MDL: 7647-14-5
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF MOLECULAR HISTOLOGY · 2026 ·Vol. 57 ·期 2 ·112 · IF 2.6

Acupuncture modulates actin homeostasis and promotes myelin sheath regeneration in rat models of intracerebral hemorrhage

Wu Zhe,Zou Wei

The relationship between actin dynamics and remyelination after intracerebral hemorrhage (ICH) remains unclear. This study aims to investigate the mechanism by which scalp acupuncture (SA) regulates remyelination in acute ICH rats through the PAK1/LIMK1/CFL1 signaling pathway. The Male Sprague-Dawley rats were used to establish the ICH model by autologous blood injection. The treatment group SA intervention, with the selective inhibitor of PAK1, IPA-3, used as a positive control. The regulatory effect of SA on the PAK1/LIMK1/CFL1 signaling pathway after ICH was evaluated using neurological function assessment, Luxol fast blue staining, Western blot, and immunofluorescence staining. On the third day after ICH, there is a peak in p-PAK1 levels, and SA intervention has the best therapeutic effect. Therefore, the third day was chosen for the IPA-3 positive control experiment. The study found that the PAK1/LIMK1/CFL1 signaling pathway is activated after ICH, leading to the inhibition of filamentous actin depolymerization, resulting in severe myelin sheath loss and neurological dysfunction. Following SA or IPA-3 intervention, the PAK1/LIMK1/CFL1 pathway is inhibited, leading to the depolymerization of actin filaments and a reduction in the degree of myelin sheath loss, as well as improvement in symptoms of neurological dysfunction. SA regulates the homeostasis of actin proteins by inhibiting the PAK1/LIMK1/CFL1 signaling pathway, promoting neuronal myelin sheath regeneration after acute ICH, and improving neurological behavioral disorders. Graphical abstract

CAS / MDL: 8001-30-7
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Nature Photonics · 2026 · IF 38.1

Dipole-assisted functionalization enables long-range ordering of ZnTeSe quantum dots for efficient and stable deep-blue electroluminescence

Shen Wan-Shan,Xie Li-Ming,Fei Wen-Long,Gu Xin,Wang Ye,Li Hua-Hui,Liu Wei-Zhi,Wang Yun-Jun,Su Wen-Ming,Wang Ya-Kun,Liao Liang-Sheng

Cadmium (Cd)- and lead (Pb)-free quantum dot light-emitting diodes (QD-LEDs) are critical for next-generation, environment-friendly electroluminescent displays. However, Cd/Pb-free QD-LEDs remain severely limited in operational stability, particularly in the deep-blue region. For emission below 460 nm, the high hole injection barrier inhibits carrier balance, thus requiring high bias to reach practical levels of luminance. Here we develop a dipole-assisted strategy to enable long-range ordering and energy adjustment of ZnTeSe QDs—achieved via the surface reconstruction using 4-aminothiophenol—to reduce the hole barrier in the deep-blue region. The intramolecular dipole deriving from the aromatic-bridged amine and thiol moieties of 4-aminothiophenol ensures the ordering arrangement of QD films and reduces the energy between the vacuum and the Fermi level, leading to the upshift of both valence and conduction band without affecting the deep-blue emission. As a result, devices emit at 452 nm with a peak external quantum efficiency of 23.6% at luminance values of 800 cd m −2 and maintain an external quantum efficiency of 22% at 1,000 cd m −2 . Moreover, our LEDs achieve a calculated operational half-lifetime exceeding 50,000 h at an initial luminance of 100 cd m −2 . Our results establish a benchmark for eco-friendly QD-LEDs towards practical applications in display technologies.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CELLULOSE · 2026 · IF 4.6

Cellulose nanofiber aerogel-encapsulated GO@LDH nanocomposite for effective simultaneous removal of copper(II) and chromium(VI) contaminants

Guo Mingjie,Liang Qianyong,Xu Shengjun,Zhong Qiaozhu,Wang Wei,Zhang Yan,Pan Ying,Wu Dihua,Zhang Dong,Lü Ting,Zhao Hongting

This work engineered an innovative cellulose nanofibrils aerogel-immobilized graphene oxide (GO)/magnesium–aluminum layered double hydroxide (LDH) nanostructure (LDGC) for the effective simultaneous sequestration of Cu(II) and Cr(VI) ions in aqueous solution. The composite was synthesized through a facile physical encapsulation method, combining the high porosity of cellulose nanofiber (CNF) aerogels with the multifunctional adsorption sites of GO@LDH. Structural analysis demonstrated that LDGC possessed a markedly increased specific surface area (43.78 m 2 ·g −1 ) relative to its constituent materials, coupled with a high density of oxygen-functionalized moieties conducive to heavy metal coordination. Batch adsorption studies revealed outstanding simultaneous removal performance (85 mg·g −1 for Cu(II) and 88 mg·g −1 for Cr(VI) in binary-component systems), representing 318% and 161% improvement compared to single-ion conditions, respectively. Kinetic analyses aligned with the pseudo-second-order model (R 2  > 0.99), suggesting predominant chemisorption mechanisms. The composite maintained > 93% efficiency after 4 regeneration cycles and showed strong resistance to common interfering ions (Ca 2 ⁺/SO 4 2 ⁻ increased adsorption by 92–105%). This work provides a sustainable strategy for simultaneous heavy metal removal, addressing critical challenges in wastewater treatment through rational design of multifunctional nanocomposites.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTRONIC MATERIALS · 2026 · IF 2.8

Graphite Composite Ink-Modified Knitted Fabric for Fabricating Highly Sensitive, Robust, and Breathable Wearable Monitoring Sensors

Dong Meng,Cai Jun,Wu Ruokai,Hao Juan,Wu Kaihong,Dong Hui

Flexible, high-sensitivity, breathable strain sensors have great potential for application in wearable electronics. Existing wearable sensors are usually assembled with polymer encapsulation layers on thin-film substrates. The discomfort caused by low permeability and mechanical mismatch restricts people’s enthusiasm for selection. In this work, high-adhesion conductive graphite–carbon black composite inks were prepared using modified epoxy as the binding agent. Durable, breathable, and wearable strain sensors were successfully fabricated by dip-padding knitted fabrics with the conductive composite ink. The developed graphite composite sensor exhibits a broad tension sensing range (up to 20%) with high sensitivity (gauge factor up to 64), a wide pressure sensing range (0–50 kPa), fast response/recovery times (60 ms/70 ms) under pressure strain, and good air permeability and mechanical durability. Additionally, this wearable sensor can effectively detect subtle-scale pulse signals and large-scale human movements, showcasing promising applications in practical wearable electronics for continuous and reliable human behavior monitoring.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Microbial Cell Factories · 2026 · IF 5.8

Efficient production of glycine from glucose via a two-stage biosynthetic strategy

Chen Lei,Zheng Zhijie,Chen Feifei,Wang Weipeng,Huo Siqi,Li Xiangyu,Zhang Alei,Chen Kequan

Background High-quality glycine is widely used in the cosmetics and pharmaceutical industries. Conventional chemical synthesis of glycine is disfavored because it relies on toxic reagents and complex downstream purification. Results Herein, we established an efficient two-step biosynthetic process for producing glycine from glucose. First, an l -threonine−overproducing strain was used to synthesis l -threonine via 50 L fed-batch fermentation, achieving a titer of 119.3 g/L. Then, a highly active l -threonine aldolase ( Pp LTA) was screened to convert l -threonine into glycine. To overcome thermodynamic and acetaldehyde inhibition constraints, an acetaldehyde elimination system was constructed via introducing Sc ADH1 and Sc CR, which increased the molar conversion yield of glycine increased by 3.9-fold. Whole-cell catalysis gave a significantly higher conversion yield than crude enzyme preparations. A whole-cell co-expressing Pp LTA, Sc ADH1, and Sc CR was subsequently constructed. Finally, at 50 L scale, direct conversion of l -threonine fermentation broth afforded a glycine titer of 65.4 g/L within 24 h, with a molar conversion yield of 87.2%, In addition, 99.8% pure glycine was obtained with a yield of 76.6% via separation. Conclusions An efficient two-step process for converting glucose to glycine was developed and successfully validated. Evaluation at the 50 L scale demonstrated record-high glycine production performance. This work provides a promising technological route for the industrial manufacture of high-quality glycine. Graphical

CAS / MDL: 56-40-6 72-19-5
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE · 2026 · IF 3.4

Effects of monascus -fermented soybean powder on the quality, isoflavones composition and sensory acceptance of steamed bread

Wang Yue,Tang Xiaohan,Zhao Huarong,Pan Yue,Zhang Dingnan,Liu He,Zhu Danshi

Most studies only preliminarily assessed the effects of non-grain supplemental levels on the physicochemical and nutritional properties of steamed bread, and few further analyzed the ways to improve its quality by changing the properties of raw materials themselves. This study investigated the effect of Monascus -fermented autoclaved whole soybean flour (FAWSF) and autoclaved whole soybean flour (AWSF) as wheat flour substitutes in making steamed bread. The contents of protein and soluble dietary fiber were higher in FAWSF than in AWSF. Steamed bread substituted with FAWSF significantly reduced the degree of crystallization and retrogradation. Furthermore, the steamed bread with 5% FAWSF was better than the control in terms of specific volume, texture, total phenolic content, and soybean isoflavones, improving the overall quality of steamed bread. Therefore, FAWSF is a promising new food ingredient.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Food Measurement and Characterization · 2026 · IF 3.6

Effects of ultrasound-assisted fermentation on jujube juice flavor: insights from GC-IMS and metabolomics

Chen Yunli,Li Shunfeng,Zhang Lihua,Li Kexin,Du Xinxin,Wang Xiaoyuan

In this study, the effects of three ultrasound-assisted methods (ultrasound treatment of Lactobacillus plantarum CICC 20022: UST-1, ultrasound treatment of fresh jujube juice: UST-2, ultrasound treatment of fermented jujube juice: UST-3) combined with fermentation on the volatile flavor compounds and metabolites in jujube juice were compared. The results of the E -nose sensor analysis indicated that the jujube juice sample contained a considerable amount of methyl compounds, alcohols, aldehydes, ketones, and aromatic compounds. The GC-IMS identified 16 characteristic markers that could distinguish different samples of fermented jujube juice. Furthermore, the top 20 significantly differential metabolites identified by non-targeted metabolomics ( P  < 0.05, FC > 1.5), characterized the UST-1, UST-2, and UST-3 groups as alcohol-flavored, acid-sweetened, and compound-flavored fermented jujube juice, respectively. The identified differential metabolites were mainly enriched in amino acid metabolism and lipid degradation. Correlation analysis revealed the close relationship between key volatile flavor compounds and the differentially expressed metabolites, enabling precise flavor regulation. In conclusion, ultrasound-assisted fermentation can enhance the flavor of jujube juice, and the fermented jujube juice with UST-3 possessed a mellower taste and a greater sense of complexity.

CAS / MDL: 64-18-6
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Food Analytical Methods · 2026 ·Vol. 19 ·期 4 ·138 · IF 3

A Comprehensive Strategy for a Novel PDE-5 Inhibitor Adulterant in Foods: from Identification in Blending Liquor to Multi-Matrix Quantitative Analysis

Wang Hui,Wang Zhaoxia,Qin Jijun,Zhong Feifei,Kong Xiangling,Chen Meimei,Han Shilei,Zhang Lei,Yuan Yuan,Yin Fangping,Zhou Peng

This study developed a comprehensive strategy to identify and quantify a novel vardenafil analogue, SLX-2101, which was detected as an undeclared adulterant in functional foods. The compound was initially screened and characterized using ultra-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UHPLC-UV-Q-TOF/MS), and its structure was confirmed via nuclear magnetic resonance (NMR) spectroscopy and comparison with a custom-synthesized reference standard. A quantitative ultra-performance liquid chromatography–tandem mass spectrometry (UHPLC-QqQ/MS) method was established and validated, demonstrating good linearity (1.0–100.0 μg/L, r  > 0.997), with a limit of detection of 0.3 μg/kg and a limit of quantification of 1.0 μg/kg. Mean recoveries ranged from 74.2% to 115.8% across various food matrices, with relative standard deviations between 0.4% and 12.5%. Application to 61 commercial samples revealed SLX-2101 in two functional wines marketed for their purported aphrodisiac effects at concentrations of 19.3 mg/kg and 1.3 × 10 3  mg/kg. The validated method enables reliable surveillance of this emerging adulterant, thereby providing a practical solution to address the critical gap left by conventional targeted screening protocols.

CAS / MDL: 540-69-2 64-18-6 64-19-7
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF FLUORESCENCE · 2026 · IF 3.4

A Schiff Base-Functionalized Triphenylamine Fluorescent Probe for Selective and Sensitive Detection of Cu2+ in Aqueous Media

Liu Long,Chen Jiayi,Ye Meijun,Huang Wen,Liao Xiang,Wu Hanqing,Xu Jingshui

Heavy metal Cu 2+ from industrial discharge continuously accumulates in ecosystems, posing threats to human health and ecological balance. Researchers successfully synthesized a novel fluorescent probe, TPA-OPD , via a Schiff base reaction between triphenylamine and o-phenylenediamine. TPA-OPD exhibits rapid, highly selective, and sensitive fluorescence quenching in response to Cu 2+ , along with excellent anti-interference capability. The binding mechanism between Cu²⁺ and TPA-OPD was confirmed by Job’s plot, Fourier-transform infrared spectroscopy, mass spectrometry, nuclear magnetic resonance, and Gaussian calculations. TPA-OPD effectively detects Cu 2+ in real-world environmental samples such as tap water and river water, demonstrating strong potential for monitoring Cu 2+ pollution. Graphical None = 95% H2O, 1 = Cu²⁺, 2 = Na⁺, 3 = K⁺, 4 = Cs⁺, 5 = Mg²⁺, 6 = Al³⁺, 7 = Ca2+, 8 = Ba²⁺, 9 = Cd²⁺, 10 = N₂H₆²⁺, 11 = Sr²⁺, 12 = NH₄⁺, 13 = Co2+, 14 = Zn2+, 15 = Ag+, 16 = Ni²⁺, 17 = SO₄²⁻, 18 = CO32-, 19 = Cl- , 20 = NO₃⁻, 21 = CH₃COO⁻

CAS / MDL: 7631-99-4
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
IONICS · 2026 · IF 3.4

Accurate measurement of ammonia nitrogen in water based on ammonium ion-selective electrodes with a hydrophobic layer and a parameter compensation strategy

Liu Chenyu,Lu Shengkang,Yin Jiawen,Jin Qinghui

Ammonia nitrogen (NH₃-N) serves as a critical water quality indicator, with excessive levels posing risks to human health. Conventional detection methods like Nessler’s reagent and salicylate colorimetry suffer from toxic byproduct generation and operational complexity. Ammonium ion-selective electrodes (NH 4 + -ISEs) offer advantages such as reagent-free and real-time monitoring. However, during practical detection, they are susceptible to interference from unknown conditions (primarily including pH value, temperature, and potassium ions) in complex aqueous environments. In this work, we developed an all-solid-state ammonium ion-selective electrode (ASS-NH 4 + -ISE), and eliminated the aforementioned interferences through multi-sensor collaborative detection and parameter compensation. The electrode is characterized by a hydrophobic polyaniline (PANI) solid contact layer doped with perfluorooctanoic acid (PFOA), whose hydrophobicity can effectively suppress the formation of a water layer. The electrode exhibited a Nernstian slope of 58.57 mV/dec, a limit of detection (LOD) of 2.95 µM, meeting requirements for drinking water and seawater monitoring. Furthermore, by incorporating potassium ion-selective electrode (K⁺-ISE) calibration, pH compensation, and temperature coefficient correction, accurate NH₃-N quantification under diverse conditions was achieved. We tested the ammonia nitrogen concentration in actual water samples under different interference conditions, and the recovery rate ranged from 98.1% to 105.1%, which verified the effectiveness of the system for real-time monitoring of ammonia nitrogen in complex aquatic environments. In this study, we integrated a hydrophobic solid SC layer with a multi-parameter (K⁺/pH/temperature) compensation strategy, enabling reagent-free, real-time monitoring of NH₃-N in complex water bodies without any pretreatment. This approach overcomes the limitations of previous ISEs.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
BIOMEDICAL MICRODEVICES · 2026 ·Vol. 28 ·期 1 ·18 · IF 4.4

Dual-Mode sensing patch for visual glucose detection enabled by an AuNPs-PAM nanozyme cascade

Pang Zhengtian,Song Wenqi,Cai Yuanyuan,Li Yahang

Wearable sensors represent a promising platform for the non-invasive and continuous monitoring of biomarkers in biological fluids, showing considerable potential for real-time health management. In this study, we designed a wearable device integrated with gold nanoparticles (AuNPs) for glucose detection. The system features in-situ synthesized AuNPs embedded in a polyacrylamide (PAM) hydrogel—denoted as AuNPs@PAM—enabling dual-mode readout through both visual observation and UV–visible spectrophotometry. By leveraging the dual peroxidase-like and glucose oxidase-like activities of AuNPs, a nanozyme-enzyme cascade catalytic system was constructed for colorimetric glucose sensing, which demonstrated high sensitivity and strong stability. The in-situ synthesis of AuNPs within the PAM matrix enhances nanoparticle stability and increases the reactive surface area, thereby improving catalytic efficiency. Owing to the high flexibility and optical transparency of the PAM hydrogel, the sensing patch enables rapid and reliable glucose detection by both instrumental and visual means. Consequently, a sensitive and visually responsive flexible sensor has been successfully fabricated, offering an effective tool for non-invasive biomarker monitoring in superficial biofluids.

CAS / MDL: 54827-17-7
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。