文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,438+ SCI 论文 与阿拉丁产品引用相关
2,295,919.25 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第373至376个,产品总数376个

设置提升方向
PEDOT:PSS
Small · 2023 ·Vol. 20 ·期 19 ·2308778 · IF 13.3

3D Printing of Robust High-Performance Conducting Polymer Hydrogel-Based Electrical Bioadhesive Interface for Soft Bioelectronics

Jiawen Yu,Rongtai Wan,Fajuan Tian,Jie Cao,Wen Wang,Qi Liu,Hanjun Yang,Jingcheng Liu,Ximei Liu,Tao Lin,Jingkun Xu,Baoyang Lu

Electrical bioadhesive interface (EBI), especially conducting polymer hydrogel (CPH)-based EBI, exhibits promising potential applications in various fields, including biomedical devices, neural interfaces, and wearable devices. However, current fabrication techniques of CPH-based EBI mostly focus on conventional methods such as direct casting, injection, and molding, which remains a lingering challenge for further pushing them toward customized practical bioelectronic applications and commercialization. Herein, 3D printable high-performance CPH-based EBI precursor inks are developed through composite engineering of PEDOT:PSS and adhesive ionic macromolecular dopants within tough hydrogel matrices (PVA). Such inks allow the facile fabrication of high-resolution and programmable patterned EBI through 3D printing. Upon successive freeze-thawing, the as-printed PEDOT:PSS-based EBI simultaneously exhibits high conductivity of 1.2 S m −1 , low interfacial impedance of 20 Ω, high stretchability of 349%, superior toughness of 109 kJ m −3 , and satisfactory adhesion to various materials. Enabled by these advantageous properties and excellent printability, the facile and continuous manufacturing of EBI-based skin electrodes is further demonstrated via 3D printing, and the fabricated electrodes display excellent ECG and EMG signal recording capability superior to commercial products. This work may provide a new avenue for rational design and fabrication of next-generation EBI for soft bioelectronics, further advancing seamless human-machine integration.

研究领域: 生物医学工程 · 材料科学 · 软体机器人 · 神经科学 · 可穿戴技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Journal of Energy Chemistry · 2025 · IF 14.9

Enhancing bromine redox conversion via electrochemical self-induced catalyst gel encapsulation strategy toward high energy efficiency bromine-based flow battery

Sinan Zheng,Yang Wang,Bin Luo,Leilei Sun,Guosheng Duan,Zhean Bao,Li Gong,Jingyun Huang,Zhizhen Ye

Benefiting from features such as high-voltage platforms, superior energy density, and cost-effectiveness, Zinc-bromine flow batteries (ZBFBs) demonstrate significant potential for large-scale energy storage applications. However, their practical implementation faces critical challenges: sluggish Br 2 /Br − redox reactions and severe shuttle effects, which lead to diminished energy efficiency and self-discharge. Here, we develop an innovative electrochemical self-induced catalyst gel encapsulation strategy. Under electrochemical driving, the poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS, abbreviated as PES) catalyst spontaneously undergoes gelation and coating on carbon fibers, thereby forming a PES@C composite cathode with enhanced bromine conversion reversibility. This innovative strategy effectively addresses three critical challenges in existing ZBFBs: shuttle effect, low bromine utilization, and poor energy efficiency. PES@C with sulfur sites and C–O-C group enable efficient bromine/poly-bromide anchoring through strong polar interactions, effectively suppressing shuttling effects. Furthermore, the abundant active sites exhibit exceptional catalytic activity towards Br 2 /Br − redox reactions. This synergistic adsorption-catalysis mechanism significantly enhances the electrochemical performance of ZBFBs. The ZBFBs with PES@C achieve stable operation under ultrahigh current density (200 mA cm −2 ) and high areal capacity (40 mA h cm −2 ), delivering outstanding voltage efficiency (84.91%) and energy efficiency (81.78%). Notably, the proposed strategy demonstrates universal applicability for performance enhancement in various bromine-based battery systems, providing an efficient pathway to improve energy efficiency and cycling durability in bromine-based flow batteries.

研究领域: 储能技术 · 电化学 · 材料科学 · 催化 · 可再生能源 · 电池技术 · 化学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SOLAR ENERGY MATERIALS AND SOLAR CELLS · 2016 · IF 4.732

Efficient planar heterojunction perovskite solar cells with weak hysteresis fabricated via bar coating

Xuan Liu,Xinxin Xia,Qiuquan Cai,Feilong Cai,Liyan Yang,Yu Yan,Tao Wang

We report efficient, planar heterojunction perovskite solar cells prepared via bar coating that are compatible with large-scale fabrication on flexible substrates . Our MAPbI 3 perovskite devices by bar coating method achieved a maximum power conversion efficiency (PCE) of 13.0% using a ITO/PEDOT: PSS/CH 3 NH 3 PbI 3 (MAPbI 3) /PCBM/Ag structure, and there is very weak hysteresis in these devices. After formulation of the precursor solution and optimization of the coating process , planar perovskite thin films containing large-size grains with low surface roughness were obtained. We found that anti-solvent plays an important role in determining the uniformity, size of grains and width of grain boundaries in perovskite films. The addition of 5   vol% isopropanol into the precursor solution leads to the formation of large aspect ratio grains with a length ca. 200   µm and width of a few hundred nanometers , together with narrow grain boundaries. However, the absence or excessive of isopropanol result in perovskite films with high surface roughness and broad grain boundaries due to inefficient crystal growth or the formation of ridges between crystal grains. These grain boundaries have high PL intensity due to charge recombination and consequently deteriorate device efficiency. When bar-coating the perovskite films in air, best devices with PCE over 11% can be achieved with a relatively high humidity around 50%, eliminating the low humidity requirement during air processing.

研究领域: 材料科学 · 太阳能 · 纳米技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2025 · IF 7.7

Charge transfer-enhanced OECT glucose sensor with superabsorbent polymer composites for non-invasive breath analysis

Sheng Huang,Xiangyi Bai,Zhenyu Xu,Li Meng,Shasha Gao,Lei Zhu,Qiuchen Yu,Man-Kay Law

To address the limitations of traditional blood glucose monitoring in industrial environments, this study presents a charge transfer-enhanced glucose sensor based on organic electrochemical transistor, utilizing a carboxymethyl cellulose-modified PEDOT:PSS with aminated multi-walled carbon nanotubes/gold nanoparticles composite film. The sensor is integrated with superabsorbent polymer composites for non-invasive breath analysis. Molecular electrostatic potential calculations reveal that hydrogen-bond networks between carboxymethyl cellulose carboxyl groups and glucose hydroxyl moieties, together with π-π interactions of glucose molecules at the composite surface, enhance interfacial charge transfer efficiency by 2.5 % (0.236e→0.242e). Structural characterization confirms a honeycomb-like porous architecture (0.5–2 μm pore size) formed via carboxymethyl cellulose-mediated hydrogen bonding, accelerating glucose diffusion while suppressing interferent adsorption (response<1 %). The composite's three-dimensional conductive network combines PEDOT:PSS (p-type pathways), carbon nanotubes (surface area expansion) and gold nanoparticles (catalytic sites), achieving a linear detection range of 2–22 μmol·L⁻¹ (extendable up to 9 mM) in exhaled breath condensate with 56.656 μA·(mmol·L⁻¹·cm²)⁻¹ sensitivity, 0.2 μmol·L⁻¹ detection limit (S/N = 23.8), and < 4.8 s response time. The sensor-integrated facemask platform uses superabsorbent polymer to maintain 100 % relative humidity, stabilizing the electrolyte layer for real-time monitoring. Machine learning (random forest classifier processing 18 time-frequency features from transistor outputs) achieves 87.5 % accuracy in resolving glucose fluctuations. This work demonstrates the integration of hierarchical materials, interfacial charge control, and algorithmic processing for wearable biosensors in health monitoring.

研究领域: 生物传感器 · 有机电子学 · 纳米技术 · 分析化学 · 可穿戴设备 · 生物医学工程 · 高分子科学 · 机器学习 · 健康监测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。