文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第49至60个,产品总数83个

设置提升方向
3-(2
TALANTA · 2017 · IF 4.162

A MWCNTs-Pt nanohybrids-based highly sensitive electrochemiluminescence sensor for flavonoids assay

Hong Ke,Xin Zhang,Weiwei Guo,Amin Zhang,Zhiming Wang,Chusen Huang,Nengqin Jia

Electrochemiluminescent (ECL) assay has gradually drawn increasing interest to be considered as one of the potential strategies to be applicable in a wide range of medicine target determination. In this protocol, a facile and ultrasensitive ECL sensor platform was developed aiming at rapidly quantitative detection of polyphenolic flavonoids based on multiwall carbon nanotubes (MWCNTs)/platinum nanoparticles (PtNPs) nanohybrids/nafion/Ru(bpy) 3 2+ modified glassy carbon electrode (GCE) in Ru(bpy) 3 2+ /tri- n -propylamine (TPA) co-reaction system. Attributed to the synergistic ECL signal amplification of both PtNPs and MWCNTs facilitating the electron transfer, this proposed sensor could sensitively analyze the flavonoids through an annihilation ECL emission mechanism since the less generated amount of excitation state Ru(Ⅱ)* on account of the principle that flavones are prone to donate electrons and scavenge free radicals to further show a competitive relationship with Ru(Ⅲ) on the reaction with TPA*. The influences of pH, Ru(bpy) 3 2+ absorption time and TPA co-reactant concentration were investigated and the sensor exhibited a linear response to flavonoids when the concentration ranges from 6.50×10 –11 to 1.00×10 −7   M with a detection limit (LOD) of 2.17×10 –11   M (S/N=3) upon the optimized conditions. Furthermore, high sensitivity, excellent stability and reproducibility were verified to declare the promise for being applicable to analyze the flavones content in real flavones medicine samples and ginkgo leaves extracts with satisfactory results.

CAS / MDL: 7447-40-7
研究领域: 分析化学 · 纳米技术 · 药物分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2021 · IF 6.986

Atom-Anchoring Strategy with Metal–Organic Frameworks for Highly Efficient Solid-State Electrochemiluminescence

Xinyang Zhu,Huanhuan Xing,Yuan Xue,Jing Li,Erkang Wang,Shaojun Dong

A chemical fixation strategy originating from single-atom-anchoring with metal–organic frameworks as a carrying matrix was proposed for solid-state electrochemiluminescence (ECL). Herein, UiO-67(N) with the exposure of 2,2′-bipyridine (bpy) ligands could coordinate with Ru2+ to form a local structure of [Ru(bpy)3]2+ (Ru-UiO). The influence of the steric effect induced with different Ru sources was discussed. The as-obtained Ru-UiO exhibits high ECL intensity and outstanding stability in the presence of a coreactant at low concentrations. The proposed synthesis strategy may hold great potential for the synthesis of solid-state ECL materials and their further utilization in ECL analysis.

研究领域: 材料科学 · 分析化学 · 电化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2021 · IF 7.46

An ultrasensitive photoelectrochemical sensor with layer-by-layer assembly of chiral multifarene[3,2,1] and g-C3N4 quantum dots for enantiorecognition towards thyroxine

Yong-Yi Zhao,Huan Luo,Qingmei Ge,Mao Liu,Zhu Tao,Hang Cong

With a facile preparation for graphitic carbon nitride quantum dots (g-C 3 N 4 QDs), an ultrasensitive photoelectrochemical (PEC) sensor was developed with the supramolecular affinity of chiral multifarene[3,2,1] (CMF) to a hormone drug, thyroxine (T 4 ), for efficient identification of thyroxine enantiomers. In the principle that g-C 3 N 4 QDs was employed to achieve the photocurrent response and the macrocyclic compound served as the supramolecular enantiorecognition for thyroxine, the photoelectrochemical electrode was constructed by layer-by-layer assembly of g-C 3 N 4 QDs and CMF on the surface of ITO (ITO-g-C 3 N 4 -CMF QDs). The proposed PEC sensor produced the limits of detection low to 67 pM towards L -T 4 and 85 pM towards D -T 4 in a concentration range from 0.1 nM to 10 nM, which was superior to the values in pioneering reports with colorimetric or electrochemical methods. With good stability, reproducibility, repeatability anti-interference ability, and acceptable recoveries, the proposed PEC sensor was employed for quantitative determination of L/D -T 4 in water, human serum and commercial tablet.

研究领域: 分析化学 · 生物医学工程 · 药物分析
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
LWT-FOOD SCIENCE AND TECHNOLOGY · 2021 · IF 4.952

Headspace solid-phase microextraction and on-fiber derivatization for the determination of 3-/2-MCPDE and GE in breast milk and infant formula by gas chromatography tandem mass spectrometry

Shihuan Li,Jinhui Li,Senwei Feng,Linlin Bian,Zhuoting Liu,Yunfang Ping,Xu Wang,Ann Van Schepdael

The presence of fatty acid esters of 3-monochloropropane-1,2-diol (3-MCPDE), 2-monochloropropane-1,3-diol (2-MCPDE) and glycidyl (GE) in foods is a potential concern due to their toxicity, especially for infants. This study proposed a rapid, sensitive and environmentally friendly method for simultaneous determination of the 3-/2-MCPDE and GE in breast milk and infant formula using headspace solid-phase microextraction (SPME) and on-fiber derivatization combined with gas chromatography-tandem mass spectrometry (GC-MS/MS). The approach proved high sensitivity with detection limits of 0.10 μg/L and 0.15 μg/kg for MCPDEs in breast milk and infant formula, respectively. Mean recoveries were obtained ranging from 79.9 to 111.2% for breast milk and from 82.1 to 106.7% for infant formula, with relative standard deviation (RSD) of less than 9.5%. According to the levels of 3-MCPDE and GE determined in 30 breast milk and 23 infant formulas, the exposure to 3-MCPDE and GE may pose a potential health risk for infants from birth to <12 months fed by breast milk and infants from birth to 6 months fed by infant formula.

CAS / MDL: 98-80-6
研究领域: 食品安全 · 分析化学 · 毒理学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
TALANTA · 2021 · IF 6.057

Mesoporous silica-mediated controllable electrochemiluminescence quenching for immunosensor with simplicity, sensitivity and tunable detection range

Yi Xiao,Suhua Chen,Simeng Zhang,Guofang Wang,Haomin Yi,Gui-Zhong Xin,Xiaoping Yang

Straightforward and accurate measurement of medical biomarkers is of essential importance in clinical diagnostics and treatments. However, the major challenge is the diversity in dynamic range of different biomarkers ranging from pg mL −1 to μg mL −1 in various body fluids and tissues among patients. Here, we develop a mesoporous silica (MS)-mediated controllable electrochemiluminescence (ECL) quenching of immunosensor that allows accurate immunoassays with simplicity, sensitivity and tunable sensing range. MS is employed to enhance the sensitivity and tune ECL quenching to broaden the detection range just by altering luminophore (Ru(bpy) 3 2+ ) and coreactant (DBAE) concentration without additional modifications. The immunoassay is followed: homogeneous sandwich immunoreaction, magnetic separation, and ECL quenching detection. As a proof-of-concept, simple and sensitive detection of IgG is achieved ranging from pg mL −1 to μg mL −1 , and applications of the strategy are extended by the combination of ECL immunosensor with commercial ELISA kit. This study will not only be expected to serve as a new avenue for the assay of physiological and clinical implications of immunological biomarkers, but also benefit a wide range of applications that require a tunable detection range and ultrahigh sensitivity.

研究领域: 分析化学 · 生物医学工程 · 临床诊断
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2019 · IF 9.518

Signal-on electrochemiluminescence aptasensor for bisphenol A based on hybridization chain reaction and electrically heated electrode

Huifang Zhang,Fang Luo,Peilong Wang,Longhua Guo,Bin Qiu,Zhenyu Lin

A simple and sensitive electrochemiluminescence (ECL) aptasensor has been developed for bisphenol A (BPA) detection. The capture DNA (CDNA) was modified on the heated indium-tin-oxide (ITO) working electrode surface firstly and then hybridized with BPA aptamer to form double strand DNA (dsDNA). The presence of target can cause the releasing of aptamer from the electrode surface since the aptamer prefers to switch its configuration to combine with BPA. Subsequently, the free CDNA will induce hybridization chain reaction (HCR) to produce long dsDNA on the electrode surface. Ru(phen) 3 2+ can integrate into the grooves of dsDNA to act as an ECL reagent, thus enhanced ECL signal can be detected. The temperature control during the processes of target recognition and HCR were realized through the heated electrode instead of the bulk solution heating. Furthermore, the performance of the ECL aptasensor can be further enhanced at elevated electrode temperature. Under the optimized conditions, the ECL intensity of the system has a linear relationship with the logarithm of BPA concentration in the range of 2.0 pM-50 nM. The limit of detection (LOD) at 55 °C (electrode surface temperature) was calculated to be 1.5 pM, which was approximately 6.5-fold lower than that at 25 °C. The proposed biosensor has been applied to detect the BPA in drink samples with satisfactory results.

研究领域: 分析化学 · 环境科学 · 生物化学 · 传感器与执行器
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2023 · IF 8.4

Co-reactant confined and vertically ordered silica nanochannel regulated electrochemiluminescence for homogeneous detection of miRNA

Jiajing Xu,Weiqiang Yang,Jiancong Ni,Qingxiang Wang,Zhenyu Lin

Electrochemiluminescence (ECL) arises from the collisional annihilation between the electro-excited luminophore and co-reactant. Most ECL-based bioassays require extensive free co-reactants that collide with luminophores randomly. Herein, the N,N-dimethylaniline (DMA) group was electro-grafted on the ITO electrode surface as the bottom co-reactant layer, and the vertically ordered mesoporous silica film (VMSF) was prepared as the upper layer to regulate the accessibility of Ru(bpy) 3 2+ . Thus, the dual-layer functionalized VMSF/N-ITO was newly built for the controllable ECL study. Relevant conditions, including the DMA electro-grafting, VMSF thickness, buffer concentration and pH value, were discussed to improve the ECL efficiency. Based on the VMSF/N-ITO platform, a homogeneous ECL bioassay was developed for miRNA-21 detection. The target nucleotide sequence induced the hybridization chain reaction (HCR) of probes H1 and H2 to absorb free Ru(bpy) 3 2+ as much as possible. Residual Ru(bpy) 3 2+ permeated the VMSF nanochannels to collide with the DMA co-reactant in producing an ECL response. There was a linear relationship between ∆ECL intensity and logarithmic concentration of miRNA-21 in the 1 fM ∼ 100 pM range, and the detection limit was 0.25 fM. The developed approach was probes immobilization-free, highly sensitive, and anti-interference, opening a new avenue for ECL-based bioassays.

CAS / MDL: 57-09-0 78-10-4
研究领域: 分析化学 · 生物化学 · 纳米技术 · 生物传感器
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2022 ·Vol. 189 ·期 11 ·1-10 · IF 6.408

Tris(bipyridine)ruthenium(II)-functionalized metal–organic frameworks for the ratiometric fluorescence determination of aluminum ions

Wang Xin,Li Longwen,Li Lihua,Bu Tong,Yang Kairong,Xia Junfang,Sun Xinyu,Jiang Hong,Wang Li

A novel ratiometric fluorescence probe was designed for the determination of Al 3+ by self-assembling of NH 2 -MIL-101(Fe) and [Ru(bpy) 3 ] 2+ . Under the excitation wavelength of 360 nm, the NH 2 -MIL-101(Fe)@[Ru(bpy) 3 ] 2+ presented a dual-emitting luminescent property at 440 and 605 nm, respectively. In the presence of Al 3+ , the blue fluorescence of NH 2 -MIL-101(Fe)@[Ru(bpy) 3 ] 2+ at 440 nm was enhanced remarkably, while the red emission at 605 nm was almost not influenced. Therefore, taking the fluorescence at 440 nm as the report signal and 605 nm as the reference signal, quantitative determination was achieved for Al 3+ concentration in the ranges 0.2–25 μM and 25–250 μM. The limit of detection (LOD) and limit of quantification (LOQ) were calculated to be 73 nM and 244 nM, respectively. The sensing mechanisms were studied by theoretical calculation and optical spectra. The analysis of real food samples confirmed the suitability of the proposed method. More importantly, portable fluorescent test papers were successfully manufactured to provide a strategy for visual, rapid, and on-site detection of Al 3+ . Graphical abstract

研究领域: 分析化学 · 材料科学 · 环境科学 · 食品科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF SEPARATION SCIENCE · 2017 ·Vol. 40 ·期 12 ·2528-2540 · IF 2.557

3-(2-Bromoacetamido)-N-(9-ethyl-9H)-carbazol fluorescent probe and its application for the determination of thiophenols in rubber products by HPLC with fluorescence detection and atmospheric chemical ionization mass spectrometry identification

Jinmao You,Kun Dou,Cuihua Song,Guoliang Li,Zhiwei Sun,Shijuan Zhang,Guang Chen,Xianen Zhao,Na Hu,Wu Zhou

A rapid, sensitive, and selective precolumn derivatization method for the simultaneous determination of eight thiophenols using 3-(2-bromoacetamido)- N -(9-ethyl-9 H )-carbazol as a labeling reagent by high-performance liquid chromatography with fluorescence detection has been developed. The labeling reagent reacted with thiophenols at 50°C for 50 min in aqueous acetonitrile in the presence of borate buffer (0.10 mol/L, pH 11.2) to give high yields of thiophenol derivatives. The derivatives were identified by online postcolumn mass spectrometry. The collision-induced dissociation spectra for thiophenol derivatives gave the corresponding specific fragment ions at m/z 251.3, 223.3, 210.9, 195.8, and 181.9. At the same time, derivatives exhibited intense fluorescence with an excitation maximum at λ ex = 276 nm and an emission maximum at λ em = 385 nm. Excellent linear responses were observed for all analytes over the range of 0.033–6.66 μmol/L with correlation coefficients of more than 0.9997. Detection limits were in the range of 0.94–5.77 μg/L with relative standard deviations of less than 4.54%. The feasibility of derivatization allowed the development of a rapid and highly sensitive method for the quantitative analysis of trace levels of thiophenols from some rubber products. The average recoveries ( n = 3) were in the range of 87.21–101.12%.

研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
PEST MANAGEMENT SCIENCE · 2024 · IF 3.8

Design, synthesis, antimicrobial activity, and mechanism of novel 3-(2,4-dichlorophenyl)-[1,2,4]triazolo[3,4-b][1,3,4]thiadiazole derivatives

Yuguo Zheng,Mei Chen,Renfeng Zhang,Wei Xue

BACKGROUND Plant pathogens cause substantial crop losses annually, posing a grave threat to global food security. Fungicides have usually been used for their control, but the rapid development of pesticide resistance renders many ineffective, therefore the search for novel and efficient green pesticides to prevent and control plant diseases has become the top priority in crop planting. RESULTS The results of bioassay studies indicated that most of the target compounds showed certain antimicrobial activity in vitro . In particular, compound X7 showed high inhibitory activity against Xanthomonas oryzae pv. oryzae ( Xoo ), with an EC 50 value of 27.47 μg mL −1 , surpassing conventional control agents such as thiazole zinc (41.55 μg mL −1 ) and thiodiazole copper (53.39 μg mL −1 ). Further studies on molecular docking showed that X7 had a strong binding affinity with 2FBW. The morphological change observed by scanning electron microscopy indicated that the surface of Xoo appears wrinkled and cracked under X7 treatment and a total of 2662 proteins were identified by label-free proteomic analysis. Three experiments have elucidated the mechanism whereby X7 induced considerable changes in the physiological and biochemical properties of Xoo , which in turn affected the reproduction and growth of bacteria. CONCLUSION This work represents a pivotal advancement, offering important reference for the research and development therapeutics in combating plant pathogens. © 2024 Society of Chemical Industry.

研究领域: 农业化学 · 植物病理学 · 药物科学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2017 · IF 7.78

Electrochemiluminescence resonance energy transfer system between GNRs and Ru(bpy)32+: Application in magnetic aptasensor for β-amyloid

Hong Ke,Haifeng Sha,Yinfang Wang,Weiwei Guo,Xin Zhang,Zhiming Wang,Chusen Huang,Nengqin Jia

Electrochemiluminescent (ECL) assay has gradually drawn increasing interest in the biomedical analysis. This paper proposed a new methodology for ultrasensitive and facile detection of Alzheimer's disease marker β-amyloid (Aβ) by fabricating a sandwich-type ECL sensing platform. Herein, electrochemiluminescence resonance energy transfer (ECL-RET) was employed to determine Aβ concentration, which can be attributed to the quenching effect from RET between Ru(bpy) 3 2+ and gold nanorods (GNRs) acting as ECL-RET electron donor and acceptor, respectively. In this protocol, mesoporous carbon nanospheres were adopted to immobilize ECL reactant Ru(bpy) 3 2+ and antibody via nafion to acquire the RET donor nanocomposites (MOCs/nafion/Ru(bpy) 3 2+ /antibody), which were tightly interconnected with epoxy group functionalized Fe 3 O 4 nanoparticles . It is of vital importance that GNRs with exquisite rod shape were synthesized and exhibited a typical absorption peak at 650   nm to quench ECL signal of Ru(bpy) 3 2+ effectively. In addition, the ECL emission decreased linearly with the logarithm of Aβ concentration in a wide linear range from 1.0 × 10 −5 to 100   ng/mL with a detection limit of 4.2 × 10 −6   ng/mL. Furthermore, distinctive and desirable properties were verified to declare the promise for being applicable to analyze the Aβ content in real Alzheimer's cerebrospinal fluid samples with satisfactory results.

CAS / MDL: 1317-61-9
研究领域: 生物医学工程 · 分析化学 · 纳米技术 · 诊断学 · 神经退行性疾病
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
LUMINESCENCE · 2021 ·Vol. 37 ·期 1 ·58-71 · IF 2.464

Novel dual-sensitization electrochemiluminescence immunosensor using photopermeable Ru(bpy)32+-doped chitosan/SiO2 nanoparticles as labels and chitosan-decorated Nafion/MWNTs composites as enhancer

Zheng Chang,Chao Zhang,Binghua Yao

A novel dual-sensitization electrochemiluminescence (ECL) immunosensor for the detection of tumour protein prostate specific antigen (PSA) at trace level using Ru(bpy) 3 2+ -doped chitosan/SiO 2 nanoparticles (Ru(bpy) 3 2+ /chitosan/SiO 2 NPs) as the first signal enhancers was fabricated. Due to chitosan with excellent pore forming capacity, these nanoparticles possess porous structures and better photopermeability, and therefore have higher luminescence efficiencies compared with Ru(bpy) 3 2+ /SiO 2 NPs reported in previous publications. Conversely, chitosan with good biocompatibility and high hydrophilicity was electrochemically decorated onto a Nafion/multiwall carbon nanotubes (Nafion/MWNTs) modified electrode surface and used as the second sensitizing matrix to seize large amounts of prostate specific capture antibody (Ab 1 ). The chitosan-decorated Nafion/MWNTs composites exhibited a 5.5-times higher ECL intensity than the unadorned Nafion/MWNTs films. Also, without additional reagents, such as (3-aminopropyl)triethoxysilane (APTS), the one-step functionalized Ru(bpy) 3 2+ /chitosan/SiO 2 NPs provided a large number of active arms to connect with PSA-detected antibodies (Ab 2 ) through the amino groups in chitosan. After a sandwich immunoreaction, the PSA antigen and Ru(bpy) 3 2+ /chitosan/SiO 2 NPs-labelled Ab 2 were sequentially captured onto the Ab 1 /chitosan/Nafion/MWNTs-modified electrode surface. The ECL signal increases were linearly related to the PSA antigen concentrations and ranged from 0.01 pg·mLl −1 to 10.0 pg·mLl −1 . Under the optimized experimental conditions, the immunosensor displayed excellent sensitivity and selectivity. The detection limit was as low as 3.4 fg·mLl −1 , equivalent to, or better than, those of the reported ECL immunosensors for PSA.

研究领域: 分析化学 · 生物传感器 · 纳米技术 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。