文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,389+ SCI 论文 与阿拉丁产品引用相关
2,303,681.05 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第841至852个,产品总数1,138个

切换升序
尿酸
ACS Applied Nano Materials · 2024 · IF 5.3

Molecularly Imprinted Electrochemical Sensor Based on CuxO/MXene Nanocomposite for Sensing of Melatonin

Xinyu Wang,Wenbin Wang,Meng Gao,Hao Yu,Min Fu,Wei Chen

A molecularly imprinted electrochemical sensor was designed for the quantitative and efficient detection of melatonin (MT) based on a CuxO/MXene modified screen-printed carbon electrode (MIP/CuxO/MXene/SPCE). Herein, the CuxO/MXene nanocomposite was prepared via a hydrothermal method. The CuxO was uniformly dispersed on the surface and the interlayers of the MXene, forming hybrid heterostructures. The encapsulated CuxO increased the interlayer distance of the MXene matrix to bring more active sites and accelerated the oxidation reaction of melatonin molecules, and thereby the electrochemical response of the sensor was improved. The MIP was constructed by electropolymerization of o-phenylenediamine (o-PD) in the presence of MT on the surface of the CuxO/MXene/SPCE. The morphology and chemical composition of the hybrid film were characterized by scanning electron microscopy and X-ray photoelectron spectroscopy; the electrochemical behaviors of the sensor were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimal conditions, the MIP/CuxO/MXene/SPCE sensor had a wide linear detection range of 5–700 μM and a low detection limit of 0.029 μM (S/N = 3) for MT. The sensor also showed excellent selectivity, reproducibility, and stability. Finally, it was successfully applied for MT detection in human urine with satisfactory recovery. Overall, this study provided a sensitive and efficient strategy for the determination of MT.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2025 · IF 5.1

Nanoprobe-free nanosensor with Tyndall-effect readout for colorimetric detection of alkaline phosphatase

Wenli Zhu,Miao Hu,Guanghua Su,Weifang Jiang,Hancong Du,Kaxi Chen,Jinfang Nie,Lang Zhang,Xuehui Tang,Yun Zhang

This work initially describes a new colorimetric nanosensor for the visual detection of alkaline phosphatase (ALP) based on analyte-mediated in-situ production of silver nanoparticles (AgNPs) that lights up the Tyndall effect (TE). In the presence of ALP, 4-aminophenol phosphate (APP) is hydrolyzed to generate 4-aminophenol (AP), which in turn reduces Ag + ions to form AgNPs. The TE signal can be observed with the naked eye in the resulting colloidal mixture under the irradiation of a handheld laser pointer pen (acting as a light source). The TE intensity is proportional to the analyte concentration in the sample. The quantitative measurement of ALP is further realized by using a smartphone for reading out the TE signal. The results obtained under optimal experimental conditions show that the proposed nanosensor is capable of quantifying ALP within a concentration range of 0.0156–8 U/L. Its detection limit for the analyte is estimated to be approximately 0.002 U/L according to the 3σ rule. Moreover, the recovery of ALP in real human serum samples ranges from 94.38 to 96.67 %, demonstrating its satisfactory analytical accuracy and practicality. To our knowledge, this may be the first report of a nanoprobe-free TE-enhanced colorimetric nanosensor for the instrument-free analysis of enzymatic activity.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Materials Chemistry C · 2024 · IF 5.7

Organic photoelectrochemical transistor based on Fe-MOF@PANI/Carbon fiber for uric acid detection

Yuedan Wang,Tao Yang,Panpan Hao,Changhui Li,Mufang Li,Yan Tan,Dong Wang

The Fe-MOF@PANI/Carbon fiber was prepared by solvothermal method and used as the gate of organic photoelectrochemical transistor (OPECT). The ratio of Fe-MOF to PANI was optimized to enhance the photoelectric signal transduction. In addition, the vertical configuration of devices was adopted to improve the sensor property. Under light illumination, the device shows good photoelectric conversion ability, periodic stability and duration stability. The uric acid biosensor was prepared by modifying the gate with urate oxidase. The sensitivity of sensors in the absence of light and under illumination is compared. The results show that the sensitivity of the sensor is significantly improved to 91.65 mV/decade under light. The linear relationship is good in the range of 1 nM-5 mM, with a correlation coefficient of R2=0.9506. The sensor can also be used under bending conditions and has been successfully applied to the detection of uric acid in human sweat samples, providing a viable solution for wearable electronic devices.

CAS / MDL: 50-70-4 69-93-2
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ELECTROCHIMICA ACTA · 2025 · IF 5.6

Pairing dual hetero single atoms Co-Cu centers to reduce H2O2 for high-performance nanozyme sensor

Juan Li,Jinggao Wu,Chang Ming Li

Dual hetero paired single atomic catalyst (DHAC, CoCu@CN) was one-pot synthesized by a facile green method and applied as a nanozyme for the detection of H 2 O 2 . Both experimental results and theoretical calculations discover that the hetero-paired DAC realizes stronger adsorption energy and a bridge adsorption of H 2 O 2 for simultaneous 2-electron transfer, thereby offering much higher electrocatalytic activity and larger catalytic current than that of single Co atom and single Cu catalyst alone toward H 2 O 2 reduction. The CoCu@CN H 2 O 2 sensor demonstrates a wide linear detection range (0.654–7379.454 μM) and low limit of detection (LOD) of H 2 O 2 (0.047 μM), and is used successfully to in-site detect intracellular H 2 O 2 released from living cells, ensuring its practical applications in life science and medical diagnosis. This work not only discloses a scientific insight for the enhancement mechanism of the dual single heteroatomic catalyst, but also demonstrates an avenue to synthesize more efficient dual single heteroatomic catalyst for potential broad applications in energy conversion and/or sensing applications.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2018 · IF 5.667

Facile and sensitive detection of dopamine based on in situ formation of fluorescent polydopamine nanoparticles catalyzed by peroxidase-like ficin

Yanjiao Pang,Ying Shi,Yadi Pan,Yufang Yang,Yijuan Long,Huzhi Zheng

Polydopamine nanoparticles (pDA NPs), a kind of popular polymer material, have been broadly applied to various areas owing to its excellent physicochemical properties. In this work, we employed ficin as a peroxidase-mimic to in situ synthesize intrinsic fluorescent pDA NPs and developed a fluorescence turn-on method for rapid dopamine (DA) sensing which is based on monitoring the intrinsic fluorescence of pDA NPs. Ficin possesses intrinsic peroxidase-like activity that could catalyze the oxidization of dopamine to its quinone derivative and autopolymerize into fluorescent pDA NPs by H 2 O 2 . Thus, the fluorescence intensity of pDA NPs gradually enhanced with increasing concentration of DA. Under the optimum conditions, the strategy showed a good linear relationship from 10 nM to 5.0 μM ( R 2  = 0.996) and provided an exciting detection limit of 5.5 nM. More importantly, the presented sensing approach has high sensitivity, good selectivity and has been successfully applied to DA sensing in human serum samples. With its good analytical figures of merit, our proposed analytical method is promising for the detection of DA-related diseases.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ELECTROCHIMICA ACTA · 2018 · IF 5.116

Facile fabrication of a non-enzymatic nanocomposite of heteropolyacids and CeO2@Pt alloy nanoparticles doped reduced graphene oxide and its application towards the simultaneous determination of xanthine and uric acid

Di Zhu,Huiyuan Ma,Haijun Pang,Lichao Tan,Jia Jiao,Tao Chen

A non-enzymatic nanocomposite of 12-heteropolyacids and CeO 2 @Pt alloy nanoparticles decorated by reduced graphene oxide (RGO), was successfully developed by a facile and eco-friendly route for simultaneous determination of xanthine (XA) and uric acid (UA). The surface morphology and structure of the nanocomposite were investigated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and fourier transform infrared spectroscopy (FT-IR), respectively. And then, the electrochemical properties of the nanocomposite were further examined by differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The as-prepared nanocomposite exhibited excellent sensing performance towards the determination of UA and XA simultaneously with a widely linear range from 4.43 × 10 −7  M to 4.52 × 10 −4  M and 1.25 × 10 −7  M to 5.73 × 10 −4  M, respectively, along with a relatively low detection limit of 5.13 × 10 −8  M and 1.34 × 10 −8  M, mainly because of the synergistic effect of the active components. Meanwhile, the nanocomposite also revealed a superb anti-interference property, as well as good stability and reproducibility. What's more, the nanocomposite was applied in detecting XA and UA in real samples with satisfactory results, demonstrating that the nanocomposite of PMo 6 W 6 /RGO-CeO 2 @Pt would be a good potential candidate sensor for practical detecting xanthine and uric acid.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CERAMICS INTERNATIONAL · 2018 · IF 3.057

Ordered mesoporous Co3O4 nanospheres / reduced graphene oxide composites for rutin detection

Jiangjiang Zhang,Shiqiang Cui,Yaping Ding,Xinxin Yang,Kai Guo,Jingtai Zhao

The ordered mesoporous Co 3 O 4 nanospheres encapsulated with reduced graphene oxide (denoted as meso-Co 3 O 4 / RGO) were synthesized via electrostatic interaction and firstly for the electrochemical detection of rutin with good sensing effects. The resultant meso-Co 3 O 4 / RGO nanocatalyst not only possesses more active sites due to the high surface area deriving from the mesoporous structure, but also has benign conductibility due to the presence of RGO, both of which enhance the sensing properties for the electrochemical detection of rutin. The developed sensor displays low detection limit (0.03 μM) and large sensitivity (74.85 μA μM −1 cm −2 ). Besides, the rutin sensor possesses good selectivity, stability and reproducibility.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2017 · IF 2.536

Fluorescent carbon dots nanosensor for label-free determination of vitamin B12 based on inner filter effect

Longhua Ding,Hongmei Yang,Shenguang Ge,Jinghua Yu

A simple and effective fluorescent assay for the determination of vitamin B 12 was developed. In this study, carbon dots (CDs) were prepared by one-pot hydrothermal method and directly used as a fluorophore in the inner filter effect (IFE). Both of the maximum absorption peak of vitamin B 12 and excitation maxima of CDs are located at 360   nm, hence, the excited light of CDs can be absorbed by vitamin B 12 , resulting in the fluorescence reduction of CDs. And the fluorescence intensity of CDs decreases with the increasing concentration of vitamin B 12 . This IFE-based sensing strategy shows a good linear relationship between the normalized fluorescence intensity and the concentration of vitamin B 12 ranging from 0 to 60   μM, with a limit of detection (LOD) of 0.1   μM at a signal-to-noise ratio of 3. Furthermore, this proposed approach was successfully applied to vitamin B 12 sensing in injections. This IFE sensing platform based on various fluorescent nanomaterials has a high promise for the detection of other biomolecules due to its inherent convenience.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ELECTROANALYSIS · 2018 ·Vol. 30 ·期 6 ·1033-1040 · IF 2.851

Online Electrochemical Monitoring of Glucose in Rat Brain with Acanthosphere-like CuOOH Nanospheres-based Electrochemical Sensor as Non-enzymatic and O2-independent Detector

Bo Li,Yongzhao Fan,Changqing Li,Xu Zhao,Kun Liu,Yuqing Lin

This study for the first time establishes a reliable non-enzymatic online electrochemical system (OECS) for selective and continuous measuring glucose in animal cerebral system. We proposed a one-step electrochemical method to synthetize a Cu nanostructure directly onto electrode, and over-oxidize it in NaOH to form acanthosphere-like CuOOH nanospheres (denoted as AN-CuOOH), which can serve as an excellent electrochemical catalyst for glucose oxidation and thus for simple and reproducible non-enzymatic glucose detection in strong alkaline solution. To validate the AN-CuOOH-based sensors for in vivo applications, we connect the sensors to a merged solution of in vivo microdialysis and 0.4 M NaOH to set up an OECS for in vivo glucose monitoring in rat brain. The response of this system has strong tolerance to the oxygen and pH fluctuation which may happen in the cerebral brain system during some physiological and pathological processes. The fabricated non-enzymatic OECS has a good linear current response to glucose within a concentration range from 10 to 1000 μΜ with sensitivity of 130.22 nA ⋅ μΜ −1 cm −2 . Additionally, the OECS is stable and does not suffer from the interference coexisting in the cerebral system. With the fabricated non-enzymatic OECS for glucose measurement, the basal level of glucose in the microdialysate from rats striatum was determined to be 248.63 μΜ (n=3). Furthermore, the glucose was clearly decreased to 26.37 % of the basal level when the rat was undergone by 20 min ischemia, and the glucose concentration was gradually restored to 99.15 % during 40 min of reperfusion. Our work propose a technically simple strategy for the fabrication of a highly reproducible non-enzymatic OECS system free from oxygen and pH interference, which is promising in exploring the molecular mechanism associated with brain functions.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2018 · IF 5.667

A solid-state electrochemical sensing platform based on a supramolecular hydrogel

Li Fu,Aiwu Wang,Fucong Lyu,Guosong Lai,Jinhong Yu,Cheng-Te Lin,Zhong Liu,Aimin Yu,Weitao Su

Supramolecular hydrogels formed from the biopolymer chitosan and zinc ions were used as disposable electrochemical sensing platforms for the determination of hydroxyl radicals and hydrogen peroxide for the first time. The enclosed chitosan hydrogel served as the electrolyte for the system. In the presence of hydroxyl radicals or hydrogen peroxide, the chitosan hydrogel underwent depolymerization, resulting in the release of zinc ions from complexes formed with the hydrogel. The changes in the current from the zinc ions were then monitored and used as a signal for determining the concentration of analyte. The proposed chitosan hydrogel sensing platform exhibited a comparable detection performance with wide linear ranges and low detection limits for the two analytes. The linear detection range could be further manipulated by varying the depolymerization time. Due to the low cost and simplicity of the preparation process, this enzyme- and DNA-free sensing platform possesses great potential for application in disposable point-of-care devices and in-field testing. Additionally, the application of the proposed chitosan hydrogel to antioxidant screening could be further explored.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2018 ·Vol. 185 ·期 3 ·1-7 · IF 5.705

Voltammetric sensing of dopamine based on a nanoneedle array consisting of NiCo2S4 hollow core-shells on a nickel foam

Dai Hongxiu,Chen Duo,Li Yuan,Cao Pengfei,Wang Nan,Lin Meng

An array consisting of homogeneous NiCo 2 S 4 hollow core-shell nanoneedles was fabricated and is shown to enable sensitive electrochemical determination of dopamine (DA). The array was grown directly on a nickel foam (NF) substrate by a two-step hydrothermal process. The hierarchical nanoarray consists of a homogeneous NiCo 2 S 4 nanoneedle core and a NiCo 2 S 4 nanosheet shell. A 3-dimensional micro/nano structure is formed due to the presence of the micropores of the NF. The electrode was characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy. Compared to a plain NF electrode, the NiCo 2 S 4 -modified NF electrode displays higher electrocatalytic activity for the oxidation of DA by differential pulse voltammetry (DPV). The sensor, best operated at a typical working voltage of 134 mV (vs. saturated calomel electrode), has a linear response in the 0.5–100 μM DA concentration range and a 0.2 μM detection limit (at S/ N  = 3). The electrode is selective over ascorbic acid and uric acid. Schematic presentation of an electrochemical sensor for selective determination of dopamine based on the use of a homogeneous NiCo 2 S 4 hollow core-shell nanoneedle array on nickel foam.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2017 · IF 3.012

Nickel oxide/carbon nanotube nanocomposites prepared by atomic layer deposition for electrochemical sensing of hydroquinone and catechol

Lu Zhao,Jing Yu,Shuzhen Yue,Lixue Zhang,Zonghua Wang,Pengran Guo,Qingyun Liu

The fabrication of nickel oxide/carbon nanotube (NiO/CNT) nanocomposites by atomic layer deposition (ALD) and their electrochemical performances for sensing hydroquinone (HQ) and catechol (CC) were investigated. NiO nanopaticles with a size of ~   4.9   nm formed by ALD were highly dispersed on the wall of pristine CNT. Then, the prepared NiO/CNT nanocomposites were used to modify glassy carbon electrode (NiO/CNT/GCE) for electrochemical detection , which presented enhanced electrochemical performances towards detecting HQ and CC. Not only were the redox peak currents of HQ and CC greatly enhanced, but also the oxidization peaks of the both phenolic isomers could be well separated. Under the optimized conditions, the current responses are linear for HQ and CC in the range of 10–500   μM and 10–400   μM, with detection limit of 2.5   μM (S/N   =   3) for both compounds.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。