Analytical Methods
·
2024
·
IF 2.7
Yunfeng Bai,Xiaoxuan Fan,Guoning Chen,Zhilong Zhao
Uric acid (UA) level is an important physiological indicator of the human body, which abnormality can lead to a series of diseases. Therefore, the immediate detection of uric acid concentration has broad application prospects. Commonly used methods for the analysis of uric acid include chromatography, high-performance capillary electrophoresis and electrochemical methods. However, these methods have the disadvantages of cumbersome sample pre-treatment, high cost, time-consuming, and the need for experimental instruments and professional operators, which are extremely unfavorable to the detection of uric acid and the diagnosis of related diseases in resource-limited areas. In this study, a portable visualization method was developed for the detection of uric acid by hydrogen peroxide (H2O2) test strips. Uric acid enzyme specifically catalyzes the oxidation of uric acid to produce H2O2, which causes a significant change in the color of the H2O2 test strip. The response has good linearity in the range of 1 ~ 50 μg mL-1. Thus, it provides a simple, rapid, and cost-effective visualized bioassay for uric acid.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Journal of Environmental Chemical Engineering
·
2024
·
IF 7.4
Aiting Chen,Nana Tang,Yanping Wei,Shuting Shi,Chuanqin Zhou,Quanguo He,Jianhua Ding
Uric acid (UA) levels are significant in the monitoring of human health, making their detection very important. In this paper, a simple and innovative electrochemical method for the detecting UA was established, using a sensing platform based on hybrid electrodes of Nickel-Metal Organic Framework (Ni-MOF) and carboxylated multi-walled carbon nanotubes (MWCNTs-COOH). Detailed investigations into the electrocatalytic activity of Ni-MOF/MWCNTs-COOH/GCE for The Ni-MOF/MWCNTs-COOH exhibited remarkable catalytic activity for UA oxidation . The detection limit was 0.005 μM, with a sensitivity calculation result of 6.377 µA µM −1 , and a wide linearity interval (0.03–10 μM, 10–300 μM). Utilizing its high sensitivity and selectivity , this sensor was used for the measurement of UA in biological fluids, including human serum and urine samples, recovery amounts being 96.6–100.8 %, and 98.9–101.3 %. This work is highly significant; offering new perspectives for the application of Ni-MOF based chemical sensors in the realms of environmental monitoring and healthcare.
✓ 已验证
产品关联
DOI
高影响因子
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
·
2024
·
IF 4.3
Wenhui Ai,Ge Chen,Jiayao Chen,Yao Jin,Xiufeng Wang,Ting Zhou,Zhiqing Zhang,Fang Wang,Guodong Zhang
The abuse of antibiotics has seriously threatened human health and living environment. Nevertheless, the detection of quinolones is currently mainly performed by high-cost and cumbersome means, such as High-Performance Liquid Chromatography (HPLC). Herein, we reported a novel method based on copper-doped MoO x nanoparticles (Cu-MoO x NPs) with peroxidase-like enhancement activity for the easy preparation, sensitive and rapid visualization of quinolone detection. Cu-MoO x NPs can make the chromogenic substrate 3,3′,5,5′-Tetramethylbenzidine (TMB) change from colorless to blue. Moreover, the addition of quantitative quinolone antibiotics can significantly accelerate the TMB oxidation reaction. Based on this phenomenon, a colorimetric method for detecting quinolone antibiotics was established with a good linear relationship ranging from 1 × 10 −6 M to 1.3 × 10 −4 M, and the detection limit was 0.310 μM for ciprofloxacin (CIP) and 0.520 μM for levofloxacin (LVFX). Furthermore, the mechanism was also explored, and the results showed that the peroxidase-like activity of Cu-MoO x NPs was probably derived from the generated OH, 1 O 2 , oxygen vacancies and partially reduced Cu + , and on the other hand was derived from quinolone antibiotics and nanozymes electrostatic interaction between them.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
MATERIALS RESEARCH BULLETIN
·
2024
·
IF 5.3
Guoxing Li,Hai-Tao Ren,Liyan Liu,Bing-Chiuan Shiu,Mei-Chen Lin,Ching-Wen Lou,Ting-Ting Li
This paper reports the preparation of BiVO 4 /BiOCl heterojunction photobiosensors with high sensitivity, stability and selectivity for detecting changes in dopamine concentration. BiVO 4 with nanostructures was prepared by electrostatic spinning, however, BiVO 4 semiconductor material is susceptible to complex inhibition of photogenerated carriers due to structural defects affecting the detection performance of the sensor, in order to solve this problem, BiVO 4 /BiOCl heterogeneous structures were prepared by hydrothermal synthesis. Not only the result of improving the interfacial charge separation efficiency, the photocurrent density was increased to 0.4 μA, but also the high sensitivity of the BiVO 4 /BiOCl heterojunction photovoltaic material for the detection of dopamine was improved. The linear response range for dopamine detection was 1-13 μM (R 2 = 0.99079) and the detection limit was 0.134 μM (S/N = 3). In addition, selective detection was achieved in the presence of a number of common interferences within human plasma, and the photocurrent response was tested for stability after sustained visible light irradiation.
✓ 已验证
产品关联
DOI
高影响因子
Nanoscale
·
2025
·
IF 5.1
Weiji Dai,Bing Wu,Fan Zhang,Yuxi Huang,Cuijiao Zhao,Yudong Zhang,Can Cui,Jing Guo,Saifang Huang
Due to the ease of synthesis and large specific surface area, Ni(OH)2 nanosheets have emerged as promising electrochemical sensing materials, attracting significant attentions in recent years. Herein, a series of oxy-hydroxides based on Ni(OH)2 nanosheets, including NiOx/Ni(OH)2@NF and (MNi)Ox/Ni(OH)2@NF (M = Co, Fe, or Cr), are successfully synthesized via the electrochemical oxidation and incorporation strategies. Electrochemical tests demonstrate that these Ni(OH)2-based oxy-hydroxides exhibit excellent electrochemical oxidation activity for glucose in alkaline electrolyte. Among these, (CoNi)Ox/Ni(OH)2@NF displays higher sensitivity of 3590.3 μA mM-1 cm-2 across a broad linear range of 10 μM to 1.14 mM, with a rapid current response time of less than 4 s. The superior sensing performances of (CoNi)Ox/Ni(OH)2@NF are attributed to the formation of abundant Ni3+ species and reactive-O atoms due to the electrochemical oxidation, and the synergistic effects of Co/Ni active sites resulted from the electrochemical incorporation process. In addition, the (CoNi)Ox/Ni(OH)2@NF demonstrates good stability and reproducibility for glucose sensing. This work fully leverages the significance of surface reconstruction of Ni(OH)2, providing new insights for the application of transition metal-based oxy-hydroxides materials in bio-sensing.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
LUMINESCENCE
·
2024
·Vol. 39
·期 8
·e4858
·
IF 3.2
Mingjun Fu,Yuwei Lan,Wenbin Bao,Guowei Li,Haiqin Lu,Liya Zhou,Huan Lan,Xixian Mo
The research outlined a novel approach for creating a sensitive and efficient ratio fluorescent probe for ciprofloxacin (CIP) detection. The method used the biomass materials passionfruit shell and diethylenetriamine as carbon and nitrogen sources, respectively, to prepare blue fluorescent carbon quantum dots (b-CQDs) with an average size of 3.29 nm and a quantum yield of 19.6% by a hydrothermal method. The newly designed b-CQDs/riboflavin ratio fluorescent probe demonstrates a distinct advantage for CIP monitoring, exhibiting a marked increase in fluorescence intensity at 445 nm upon interaction with CIP, while maintaining a stable intensity at 510 nm. In the water system, the I 445 nm /I 510 nm ratio of the fluorescent probe showed a significant linear relationship with CIP at the concentrations of 0–250 μmol·L −1 , and the probe boasts a low detection limit of 0.86 μmol·L −1 . The outstanding selectivity, broad detection range, low detection limits, and high quantum yield of the b-CQDs highlight their significant potential in the development of advanced sensing probes for efficient detection of ciprofloxacin, offering promising insights for future sensor technology advancements.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
TALANTA
·
2024
·
IF 5.6
Shuang-Ning Li,Jing Zhang,Yue-Qin Liu,Kang-Ping Zhou,Xin-Yu Jiang,Jin-Gang Yu
Low-cost transition metal vanadate-based electrochemical sensors have attracted a lot of attention recently. A cobalt vanadate and carboxylated multi-walled carbon nanotube composite (CoV/MWCNTs-COOH) was prepared by an ultrasonic-assisted assembly method. The uniform and dense MWCNTs-COOH attached to the surface of CoV not only combines the large surface area and superior conductivity of MWCNTs-COOH with the excellent electrochemical activity of CoV, but also enhances the redox reaction between CoV/MWCNTs-COOH composite and the analyte through synergistic effect of hydrogen bonding and electrostatic interaction. The electrochemical behaviors of CoV/MWCNTs-COOH composite modified glassy carbon electrode (CoV/MWCNTs-COOH/GCE) were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA) and uric acid (UA) on CoV/MWCNTs-COOH/GCE possesses good peak current signals with well-defined peak potentials. The linear ranges of AA, DA, and UA at CoV/MWCNTs-COOH/GCE are 1.0–100.0 μM, and the limits of detection (LODs; S/N = 3) are 0.4 μM, 0.03 μM, and 0.1 μM, respectively. The practicality of the designed sensor was further confirmed by the good recoveries obtained in the simultaneous measurement of actual samples including fetal bovine serum, human serum, urine, and Vitamin C tablets. Overall, the developed electrochemical sensor shows potential therapeutic applications for simultaneous determination of AA, DA and UA in biological fluids.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
TALANTA
·
2024
·
IF 5.6
Songjia Luo,Qingliu Wu,Lu Wang,Hao Qu,Lei Zheng
Electrochemical aptamer-based biosensors (EABs) have been developed for multiple important biomarkers for their convenient and real-time features. However, the application of EABs in complex biological fluids has been limited by the rapid loss of sensitivity and selectivity due to inactivation and biofouling of aptamer probes and electrodes. To address this issue, we report the preparation of a simple hydrogel-protected aptamer-based biosensor (HP-EAB) for direct detection of Doxorubicin (DOX) in whole blood. The aptamer provides excellent selectivity for the electrochemical sensor, allowing the prepared sensor to accurately detect DOX in a 50-fold diluted whole blood sample. The agarose hydrogel coating on the electrode surface allows the passage of small molecules while hindering the adsorption of biomolecules from the whole blood matrix to the electrode surface. The experimental results show that the prepared HP-EAB has high stability compared with the unprotected EAB, and the HP-EAB maintains excellent detection performance after 7 days of storage. The hydrogel coating can effectively reduce the non-specific response to the whole blood matrix and prolong the life-time of the sensor. When used to detect DOX in rabbit whole blood, the HP-EAB exhibited excellent detection performance with a detection limit of 25.9 nM (S/N = 3) and a detection range of 0.1 μM–50 μM. The developed HP-EAB provides an excellent platform for the rapid and accurate determination of important analytes in complex biological fluids.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Food Chemistry-X
·
2024
·
IF 6.5
Jingtao Wu,Yonghui Xia,Tianyu Wang,Yafeng Zhang,Guangli Li
An ultrasensitive and selective voltammetric platform combined a molecularly imprinted poly(pyrrole) membrane with Ag-nanoparticle-functionalized black phosphorus nanosheets (MIP/BPNS-AgNPs) was developed for trace GAT detection. The physicochemical properties of the MIP/BPNS-AgNPs were studied by various spectroscopic and electrochemical techniques. BPNS-AgNPs improved the ambient stability and electrochemical activity of the BPNS and possessed a large surface area for accommodating abundant templates to produce specific imprinted sites. The resulting MIP/BPNS-AgNP-modified glassy carbon electrode (GCE) greatly enhanced voltammetric responses for GAT. The MIP/BPNS-AgNP/GCE exhibited admirable GAT determination performance, with two linear responses (0.001–1 and 1–50 μM), high sensitivity (9.965 and 0.5378 μA μM −1 ), and a low detection limit of 0.2 nM. In addition, the MIP electrode could selectively detect GAT in complex matrices and retain roust responses for a month. The applicability of MIP/BPNS-AgNP/GCE toward the detection of GAT in pharmaceutical formulations, milk, and human serum was verified with satisfactory results.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF ELECTROANALYTICAL CHEMISTRY
·
2024
·
IF 4.1
Shuangshuang Tian,Liqiang Chen,Hong Zhang,Liangquan Sheng,Xinxin Wang,Deqian Huang
CdTe quantum dots (CdTe QDs) were synthesized using mercaptopropionic acid (MPA) as a stabilizer. The electrochemiluminescence (ECL) mechanism of CdTe QDs was examined at cathodic (−2.1 to 0 V) and anodic (0–1.5 V) potentials. Utilizing dissolved oxygen as a co-reactant for cathodic CdTe QDs, the addition of phenylephrine hydrochloride (PEH) triggers a burst effect on the intermediate OH at the electrode surface, resulting in a reduction of electron hole formation. Consequently, a novel method for detecting PEH in the concentration range of 0.2–10 μM has been developed. A strong linear correlation was observed between Lg C PEH and the ECL intensity ratio ( I/I 0 ) of cathodic CdTe QDs, with a detection limit of 37 nM. Tri- n -propylamine (TPrA) was utilized as a co-reactant for the anode of CdTe QDs. The addition of paliperidone (PP) occupies the oxidized vacancies of TPrA, leading to a diminished ECL signal. A new method was subsequently established to detect PP in the concentration range of 0.2 nM–1.0 μM with a detection limit of 18 pM. This method has been successfully applied to detect PEH in urine and in compound tropicamide eye drops, as well as to quantify PP content in paliperidone sustained-release tablets and serum, demonstrating excellent recovery and selectivity.
✓ 已验证
产品关联
DOI
高影响因子
MICROCHEMICAL JOURNAL
·
2025
·
IF 5.1
Le Wang,Jing Guo,Gong-Ming Qian,Yun-Chuan Li,Lei Yu,Bo-Huai Xiao
The detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA) is critical due to their significant roles in human metabolism and health. Abnormal levels of these biomolecules are linked to conditions such as mental illness, Parkinson’s disease, hyperuricemia, and leukemia. This work presents electrochemical (EC) nanoprobes for the simultaneous and highly sensitive detection of AA, DA, and UA. Using a gold-coated glass nanopipette as gold nanoelectrode (AuNE), which is functionalized with a reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) composite, the proposed sensor platform offers excellent sensitivity and selectivity for the detection of DA and UA. Furthermore, hydroxyapatite (HAP) coated AuNE is employed to target AA specifically. The recovery rate of each chemical is higher than 80 % in the mixture of AA, DA, and UA. Finally, the nanoprobes were tested in biological fluids, with recovery rates exceeding 80 % for cerebrospinal fluid (CSF) and brain interstitial fluid (BIF). This study provides a promising approach for the real-time monitoring of these critical metabolites in clinical settings.
✓ 已验证
产品关联
DOI
高影响因子
MICROCHEMICAL JOURNAL
·
2024
·
IF 4.9
Yicheng Zhou,Rongrong Qiao,Li Dong,Jiazheng Zhang,Lin Liu,Chao Liu,Xiaobo Zhang,Zhiwei Tong
A nanocomposite of 5,10,15,20-tetrakis (N-methylpyridinium-4-yl) porphyrin cobalt (III) (CoTMPyP) and titanium oxide (Ti 4 O 9 2− ) nanosheets was constructed using a stripping/self-assembly method for the first time. The morphology, structure, and composition of CoTMPyP/Ti 4 O 9 2− were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). Electrochemical impedance spectroscopy (EIS), Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were utilized to analyze the electrochemical properties and detect uric acid (UA), guanine (G), and adenine (A). Under optimized conditions (0.1 M phosphate buffer, pH 4.0), the CoTMPyP/Ti 4 O 9 2− modified glassy carbon electrode (GCE) enabled simultaneous detection of UA, G, and A with detection limits of 396, 59, and 47 nM, respectively (S/N = 3). The linear detection ranges were 0.31–16.99 μM for UA, and 0.12–4.02 μM for both G and A. The stability and anti-interference ability of the CoTMPyP/Ti 4 O 9 2− /GCE sensor were also examined. Further tests in serum samples demonstrated recoveries of 98.1–109.7 % for the biomolecules, with relative standard deviations of 0.8–6.2 %. These results indicate excellent performance of the nanocomposite sensor for electrochemical detection.
✓ 已验证
产品关联
DOI
高影响因子