文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第97至108个,产品总数211个

设置提升方向
hydroquinone
JOURNAL OF THE ELECTROCHEMICAL SOCIETY · 2019 ·Vol. 166 ·期 2 ·B35 · IF 3.12

Highly-Sensitive Simultaneous Determination of p-Phenylenediamine and Hydroquinone by Recognizing Electrochemical Reduction Responses on Bare GCE

Juanjuan Gao,Weiqing Zhu,Haiou Song,Shupeng Zhang

p-Phenylenediamine (PPD) and hydroquinone (HQ) are hair dye precursors for permanent dyeing and are used globally. We report a novel and economic approach for the selective and simultaneous detection of the cathodic peaks of PPD and HQ by using a bare glassy carbon electrode, compared with modified electrodes that are obtained by tedious or expensive functionalized and that failed to achieve a peak-to-peak separation of PPD and HQ. Linear relationships between the simultaneous cathodic peak current of PPD and HQ concentrations were obtained for 0.5–400 μM and 5–4,000 μM with detection limits (S/N = 3) of 0.163 and 0.353 μM, respectively. The glassy carbon electrode sensor was applied to determine PPD and HQ in Nanjing river water with a recovery for these two analogues of 98.7–103.9% and 98.0–102.4%, respectively.

研究领域: 分析化学 · 环境科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ELECTROCHIMICA ACTA · 2012 · IF 3.832

Electrodeposition of graphene oxide doped poly(3,4-ethylenedioxythiophene) film and its electrochemical sensing of catechol and hydroquinone

Weimeng Si,Wu Lei,Yuehua Zhang,Mingzhu Xia,Fengyun Wang,Qingli Hao

A novel poly(3,4-ethylenedioxy-thiophene) (PEDOT)/graphene oxide (GO) hybrid film was directly electrodeposited on a glassy carbon electrode. The SEM and TEM images of the as-obtained film revealed that PEDOT grew well on the surface of GO sheets with high affinity. The chemical structure of the composite was characterized by FT-IR, and the result conformed the formation of PEDOT doped by GO, leading to the enhanced electrochemical performance of the modified electrode. The composite modified electrode was utilized as an electrochemical sensor for the simultaneous detection of hydroquinone (HQ) and catechol (CT). It showed well electrocatalytic activity toward the redox of HQ and CT. Under the optimized condition, the response peak currents of the modified electrodes were linear over ranges from 2.5 to 200   μM for HQ and from 2 to 400   μM for CT. The sensor also exhibited good sensitivity with the detection limit of 1.6   μM for both HQ and CT, and good stability. This study provides a new kind of composite modified electrode for electrochemical sensors.

研究领域: 材料科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
APPLIED SURFACE SCIENCE · 2017 · IF 3.387

Poly(4-vinylphenylboronic acid) functionalized polypyrrole/graphene oxide nanosheets for simultaneous electrochemical determination of catechol and hydroquinone

Hui Mao,Meihong Liu,Zhenqian Cao,Chunguang Ji,Ying Sun,Daliang Liu,Shuyao Wu,Yu Zhang,Xi-Ming Song

Novel poly(4-vinylphenylboronic acid) (P4VPBA) functionalized polypyrrole/graphene oxide (PPy/GO) nanosheets , which combined the advantages of GO, PPy and PBA groups, were successfully prepared by a simple polymerization of 4-vinylphenylboronic acid (4VPBA) on the surface of pre-treated PPy/GO containing vinyl groups. Because of the synergistic effects of GO with excellent 2D structures and large surface area, PPy with good electronic conductivity and PBA with high recognition capability, P4VPBA/PPy/GO modified glassy carbon electrode presented excellent electrochemical sensing capabilities toward catechol (CC) and hydroquinone (HQ) with good stability, high sensitivity and selectivity, especially giving a large anodic peak potential difference between CC and HQ enough to well distinguish and simultaneously determine the two dihydroxybenzene isomers in their mixture. It is found that PBA groups on the surface of P4VPBA/PPy/GO nanosheets played an essential role for the discrimination and simultaneous electrochemical determination of CC and HQ, which may be due to the selective formation of stable cyclic esters by the covalent interaction between PBA groups and related molecules with a cis -diol in an alkaline aqueous solution. Therefore, P4VPBA/PPy/GO nanosheets can act as a good electrode material for building a steady electrochemical sensor for detecting the two dihydroxybenzene isomers with high sensitivity and selectivity.

研究领域: 材料科学 · 分析化学 · 环境科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2026 · IF 4.6

Dual-template molecularly imprinted electrochemical sensor on acupuncture needle electrodes for sensitive detection of hydroquinone and catechol

Liwen Qu,Hongying Liu,Jia Li,Yinghui Li,Xiangxiang Peng,Lihua Li,Lingao Yi

Ternary composite interface of gold nanoparticles, l -serine and molecularly imprinted polymer modified microelectrode was electrochemically fabricated. • A dual-template molecularly imprinted electrochemical sensor was constructed for the simultaneous detection of HQ and CC. • Molecular imprinting technology can achieve high selectivity for the analyte. • The platform shows potential application in pharmacology, diagnostics and electrophysiology, in-vivo and in-real. • This explore should open an access to integrate with Chinese acupuncture. Catechol (CC) and hydroquinone (HQ), typical toxic phenolic pollutants in industrial effluents, pose risks to ecosystems and human health, demanding rapid, accurate detection. Inspired by traditional Chinese acupuncture, This study developed a molecularly imprinted electrochemical sensor using acupuncture needle (ANE) as substrates. Gold nanoparticles (AuNPs) were electrodeposited on ANE for enhanced conductivity, l -Serine electropolymerized to strengthen recognition, and a melamine-based dual-template molecularly imprinted polymer (MIP) layer constructed as the sensing interface. The sensor was characterized via cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and elemental mapping techniques . It showed outstanding selectivity for HQ and CC, with a linear response of 0.1–1000 μM and detection limits of 0.021 μM (HQ) and 0.027 μM (CC), outperforming most reported sensors. In lake water analysis, it exhibited robust anti-interference, stability (RSD < 3.48%), and recoveries of 94.46%–105.6% (HQ) and 98.37%–106.08% (CC). This work integrates traditional Chinese acupuncture wisdom with modern molecular imprinting technology, providing an innovative, cost-effective strategy for on-site environmental monitoring of phenolic pollutants.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2017 · IF 3.012

Nickel oxide/carbon nanotube nanocomposites prepared by atomic layer deposition for electrochemical sensing of hydroquinone and catechol

Lu Zhao,Jing Yu,Shuzhen Yue,Lixue Zhang,Zonghua Wang,Pengran Guo,Qingyun Liu

The fabrication of nickel oxide/carbon nanotube (NiO/CNT) nanocomposites by atomic layer deposition (ALD) and their electrochemical performances for sensing hydroquinone (HQ) and catechol (CC) were investigated. NiO nanopaticles with a size of ~   4.9   nm formed by ALD were highly dispersed on the wall of pristine CNT. Then, the prepared NiO/CNT nanocomposites were used to modify glassy carbon electrode (NiO/CNT/GCE) for electrochemical detection , which presented enhanced electrochemical performances towards detecting HQ and CC. Not only were the redox peak currents of HQ and CC greatly enhanced, but also the oxidization peaks of the both phenolic isomers could be well separated. Under the optimized conditions, the current responses are linear for HQ and CC in the range of 10–500   μM and 10–400   μM, with detection limit of 2.5   μM (S/N   =   3) for both compounds.

研究领域: 材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF HAZARDOUS MATERIALS · 2021 · IF 10.588

Nucleophilic and redox properties of polybrominated diphenyl ether derived-quinone/hydroquinone metabolites are responsible for their neurotoxicity

Lei Xu,Yuting Wang,Erqun Song,Yang Song

Polybrominated diphenyl ethers (PBDEs) are a category of brominated flame retardants , which were widely used in industrial products since the 1970 s. Our previous studies indicated quinone-type metabolites of PBDEs (PBDE-Qs) cause neurotoxicity, however, their inherent toxicological mechanism remains unclear. Here, we first synthesized PBDE-Qs and corresponding reduced hydroquinone homologous (PBDE-HQs) with different pattern of bromine substitution. Their nucleophilic and redox properties were investigated. PBDE-Qs react with reduced glutathione (GSH) via Michael addition and bromine displacement reaction, whilst PBDE-HQs lack the ability of reacting with GSH. Of note, the displacement reaction only occurs with bromine on the quinone ring of PBDE-Qs but not phenyl ring. Next, electron paramagnetic resonance (EPR) analysis revealed the generation of SQ •− , along with their downstream hydroxyl radical (HO ) and methyl radical ( CH 3 ) through a PBDE quinone/semiquinone/hydroquinone (Q/SQ •− /HQ) futile cycle. In addition, a structure-dependent cytotoxicity pattern was found, the exposure of PBDE-Q/HQ with bromine substitution on the quinone ring resulted in higher level of apoptosis and autophagy in BV2 cells. In conclusion, this work clearly demonstrated that the nucleophilic and redox properties of PBDE-Qs/HQs are responsible for their neurotoxicity, and this finding provide better understanding of neurotoxicity of PBDEs.

研究领域: 环境科学 · 毒理学 · 神经科学 · 化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2016 ·Vol. 183 ·期 7 ·2289-2296 · IF 4.831

Simultaneous determination of bisphenol A and hydroquinone using a poly(melamine) coated graphene doped carbon paste electrode

Peng Juan,Feng Yun,Han Xiao-Xia,Gao Zuo-Ning

The authors describe an electrochemical sensor for simultaneous determination of bisphenol A (BPA) and hydroquinone (HQ). It is based on a carbon paste electrode doped with graphene and coated with poly(melamine) (PME/GR-CPE). The modified electrode exhibits excellent conductivity, electrooxidative activity and adsorptive capability. The differential pulse voltammetric peaks for HQ and BPA are separated by around 300 mV. Amperometric responses (at 0.5 V for HQ and 0.8 V for BPA; both vs. SCE) are linear for BPA in the 9.0 μM to 1.0 mM concentration range, and for HQ in the 7.0 μM to 1.0 mM concentration range. The respective detection limits are 10.5 nM and 74.0 nM. The sensor is reproducible, highly stable and sensitive. It was applied to the simultaneous determination of HQ and BPA in spiked tap water and waste water. A sensor based on poly(melamine) coated on graphene-doped carbon paste electrode for simultaneous determination of bisphenol (BPA) and hydroquinone (HQ) was fabricated. The sensor possessed good reproducibility and high stability. The practical application of the sensor was demonstrated by the detection of HQ and BPA in tap water and wastewater samples.

CAS / MDL: 108-78-1
研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2014 · IF 2.871

An electrochemical sensor based on the three-dimensional functionalized graphene for simultaneous determination of hydroquinone and catechol

Jie Du,Linlin Ma,Duoliang Shan,Yanru Fan,Liping Zhang,Li Wang,Xiaoquan Lu

In this study, a simple and sensitive electrochemical analytical method is developed for simultaneous detection of hydroquinone (HQ) and catechol (CC) employing the three-dimensional functionalized graphene (3DFG) modified glass carbon electrode (GCE). The 3DFG modified electrode can distinguish between HQ and CC, with higher oxidation currents in comparison with bare GCE and two-dimensional graphene (Gr) modified electrode, showing the enhanced catalytic activity. The differential pulse voltammetry (DPV) shows that the isomers can be detected sensitively and selectively at 3DFG/GCE with peak-to-peak separation about 100   mV. Under the optimized conditions, the oxidation peak current increases linearly with concentration of HQ ranged from 3.10   ×   10 −7 to 1.31   ×   10 −5   M and concentration of CC ranged from 2.50   ×   10 −7 to 1.29   ×   10 −5   M, respectively. The detection limits are 1.0   ×   10 −7   M and 8.0   ×   10 −8   M for HQ and CC (S/N   =   3), respectively. Moreover, the proposed method has been successfully applied to the simultaneous determination of HQ and CC in real water samples with satisfactory recoveries.

CAS / MDL: 120-80-9 123-31-9
研究领域: 分析化学 · 材料科学 · 环境科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2022 · IF 5.304

Switched electrochemical sensor for hydroquinone based on rGO@Au, monoclinic BiVO4 and temperature-sensitive polymer composite material

Chenxi Wang,Pengcheng Zhao,Li Zhang,Yilin Wang,Qian Fu,Rongjie Li,Jiaodi Li,Chunyan Li,Yixi Xie,Junjie Fei

In this paper, a temperature-controlled “On-Off” electrochemical sensor for the detection of hydroquinone (HQ) is constructed by using a composite film of temperature-sensitive polymer poly (N-vinylcaprolactam) (PNVCL), the nanomaterial rGO@Au and the monoclinic bismuth metavanadate (m-BiVO 4 ). The sensor exhibits good temperature sensitivity and reversibility. When the temperature drops below the Lowest Critical Solution Temperature (LCST) of the PNVCL, the PNVCL will be in a “stretched” state, which hinders the electron exchange between hydroquinone and the surface of the electrode, presenting an “Off” state for the sensor. On the contrary, when the temperature exceeds the LCST, the PNVCL will be in a “contracted” state, which hydroquinone can perform an effective redox process and generate a response current, showing an “On” status. Due to the good electroconductivity and electrocatalytic ability of rGO@Au and m-BiVO 4 , the proposed sensor showed excellent detection performances. Hence, the sensor shows wide linear ranges (2.0 to 30.0 μM and 30.0 to 152.0 μM) and low limit of detection (0.6 μM). In addition, the “On-Off” electrochemical sensor may provide new ideas for the application of intelligent polymers.

研究领域: 分析化学 · 材料科学 · 环境监测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
TALANTA · 2023 · IF 6.1

Ultrasensitive electrochemical sensing of catechol and hydroquinone via single-atom nanozyme anchored on MOF-derived porous carbon

Yongzhe Niu,Kai Kang,Beibei Wang,Lanyue Wang,Congwei Li,Xiang Gao,Zhenzhen Zhao,Xueping Ji

Single-atom nanozymes (SANs) can significantly enhance the sensitivity and selectivity of electrochemical sensing platforms due to the homogeneity of their active sites, full atom utilization, and high catalytic activity. In this study, we demonstrate the synthesis and characterization of a high-density Co-based single-atom nanozyme anchored on activated MOF-derived porous carbon (Co-AcNC-3) via a cascade anchoring strategy for ultrasensitive, simultaneous electrochemical detection of catechol (CC) and hydroquinone (HQ). The Co-AcNC-3 displays a large specific surface area , high defectivity, and abundant oxygen-containing groups, with Co atoms being atomically dispersed throughout the carbon support via Co–N bonds. The Co-AcNC-3 biosensor exhibits superior electrochemical signals for CC and HQ, with linear ranges of 4.0 μM–300.0 μM. and detection limits of 0.072 μM and 0.034 μM, respectively. Moreover, the Co-AcNC-3 biosensor has shown excellent performance in accurately detecting CC and HQ in actual samples. Our findings highlight the potential of the proposed Co-AcNC-3 biosensor as a reliable and promising sensing platform for determining CC and HQ.

研究领域: 分析化学 · 材料科学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
EUROPEAN POLYMER JOURNAL · 2023 · IF 6

Synthesis and comparative study of thermoplastic polyetherimides derived from hydroquinone diphthalic anhydride isomers with tert-butyl group

Jie Li,Shufeng Liu,Ge Zhu,Chunshan Lu,Yuxia Ba,Guofei Chen,Xingzhong Fang

Two isomeric dianhydride monomers, 1,4-bis(3,4-dicarboxyphenoxy)-2- tert -butylbenzene dianhydride (4,4′-TBHQDA) and 1,4-bis(2,3-dicarboxyphenoxy)-2- tert -butylbenzene dianhydride (3,3′-TBHQDA), were successfully synthesized from tert -butylhydroquinone and nitrophthalonitrile. Two series of polyetherimides (PEIs) were synthesized by chemical imidization using the above dianhydrides with four common commercially available diamines. The effects of dianhydrides with isomerization and tert -butyl group on the thermal properties, optical properties, melt processability, solubility, and mechanical properties of PEIs were systematically studied. Among them, PEI-2(a-d) derived from 3,3′-TBHQDA displayed better comprehensive performance than other PEIs, which showed well T g s at 234–261 ℃, good optical properties of 82–86 % at 450 nm, extremely low melt viscosities of 30–59 Pa·s at 400 ℃, excellent solubility and good mechanical properties (tensile modulus of 2.7–3.5 GPa, tensile strengths of 90–97 MPa and elongations at break of 3.4–4.8 %).

研究领域: 材料科学 · 高分子化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Nano Materials · 2024 · IF 5.3

Cu Single Atoms Embedded in N-Doped Hollow Carbon Spheres for Simultaneous Electrochemical Detection of Hydroquinone and Catechol

Xiangwei Yuan,Yao Jin,Junchun Guo,Qain Wang,Li Xu,Yongjiao Song,Xiaoli Xiong

N-doped hollow carbon spheres loaded with Cu single atoms (Cu SAs/N-CSs) were prepared via an in situ hard-template method. As an electrode catalyst, the Cu SAs/N-CSs electrochemical-sensing properties to hydroquinone (HQ) and catechol (CC) were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV), and the linear detection ranges of HQ and CC were 1–324 and 1–123 μM, respectively; the detection limits are 0.33 and 0.17 μM, respectively. The experimental and DFT calculation results show that Cu SAs/N-CSs have stronger adsorption strength and more effective affinity for CC and HQ due to the synergistic effect of dispersed Cu SAs and N-CSs, thus improving the electrocatalytic and sensing properties of CC and HQ. Furthermore, the prepared electrode has been successfully applied to the simultaneous determination of HQ and CC in practical water samples with satisfactory results.

CAS / MDL: 62-31-7
研究领域: 材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子