文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第1至12个,产品总数16个

设置提升方向
灵敏
JOURNAL OF LUMINESCENCE · 2022 · IF 4.171

Temperature sensing properties of NaYTiO4: Yb/Tm phosphors based on near-infrared up-conversion luminescence

Yuzhen Wang,Yanbin Li,Chaoyang Ma,Zicheng Wen,Xuanyi Yuan,Yongge Cao

In this study, NaYTiO 4 : Yb/Tm phosphors with different concentrations of Yb 3+ and Tm 3+ ions were synthesized by conventional solid-state reaction. Upon a 980 nm laser excitation, the up-conversion luminescence properties in a wide temperature range (303–823 K) were investigated. By employing the fluorescence intensity ratio (FIR) techniques based on the robust near-infrared emissions of thermally coupled 3 F 2,3 / 3 H 4 energy levels and 3 H 4(1) / 3 H 4(2) Stark energy levels, the calculated absolute sensitivity (S a ), relative sensitivity (S r ), and temperature uncertainty (δT) values demonstrated good temperature sensing properties. For the 3 F 2,3 / 3 H 4 energy levels, the maximum S r and minimum δT values are 1.04% K −1 and 0.010 K at 463 K, respectively. Moreover, the maximum S a is 0.32 × 10 −3  K −1  at 823 K. In addition, the thermally coupled 3 H 4 Stark energy levels present the maximum S a , S r and the minimum δT are 0.88 × 10 −3  K −1 , 0.60% K −1 and 3.17 K at 303 K, respectively. Besides, due to the ratio of blue to red emission varying with elevated temperature, the NaYTiO 4 : Yb/Tm phosphors are expected to be applied as an intuitive high-temperature indicator.

研究领域: 材料科学 · 光学材料 · 传感器技术 · 固体化学 · 功能材料
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MATERIALS RESEARCH BULLETIN · 2023 · IF 5.4

Pr3+ doped Y3GaO6 luminescent thermometer for high temperature conditions

Huimin Li,Shan Wang,Ran Pang,Lihong Jiang,Da Li,Su Zhang,Chengyu Li,Hongjie Zhang

Contactless thermometer based on fluorescence intensity ratio shows unparalleled characteristics compared with traditional contact thermometers. However, few materials are suitable for high temperature (above 573 K) measurement. In this work, Pr 3+ was selected as the emitter and Y 3 GaO 6 :xPr 3+ luminescent thermometers were designed. The phase, crystal structure and morphology were identified using X-ray diffraction, Rietveld refinement and scanning electron microscope. The spectra with multiple ranges were temperature sensitive due to the cross-relaxion mechanism that occurs in the luminescence process. The parameters for temperature measurement were determined based on the peak intensity ratio of 506 and 610 nm at different temperatures (from 293 to 823 K). Y 3 GaO 6 :0.01Pr 3+ displays excellent temperature sensitive performance, in which the relative sensitivity values increase along with the temperature in a wide temperature range and reach 4.09 % K −1 . The thermometric visualization in Y 3 GaO 6 :xPr 3+ can be achieved due to the widely varying luminescence colors at different temperatures.

研究领域: 材料科学 · 光学工程 · 无机化学 · 传感器技术 · 功能材料
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS · 2024 ·Vol. 35 ·期 11 ·770 · IF 2.8

Optimizing coverage of palladium nanoparticles for a highly sensitive hydrogen gas sensor based on nanogaps via spray-deposition

Ni Yongjian,Wang Wentian,Tang Chen,Sun Jingyuan,Zhang Weifeng,Gao Wanlei,Jin Qinghui,Jian Jiawen,Zou Jie

The Hydrogen (H 2 ) sensor based on palladium nanogaps (Pd NGs) offers the advantages of low detection limits and fast response times. It holds significant potential for early warning of H 2 leakages. However, the preparation methods of Pd NGs for such sensors are really complex. In this study, the spray-deposition method was introduced to streamline the preparation method of Pd NGs and optimize the quantity of Pd NGs by adjusting the coverage of Pd nanoparticles (Pd NPs). The effect of different coverage of Pd NPs on the gas sensing performance of the sensor was investigated. The results revealed that sensors with lower coverage exhibited higher H 2 sensitivity. The sensor exhibited a response time of 10 s at room temperature and shorten to 2 s at 100 °C in 2500 ppm H 2 . Furthermore, the sensor achieved a detection limit as low as 50 ppm. These findings offer a method for effectively optimizing the sensing performance of Pd NGs based H 2 sensors.

研究领域: 传感器技术 · 纳米材料 · 气体传感 · 功能材料 · 环境监测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHINESE JOURNAL OF CHEMISTRY · 2016 ·Vol. 34 ·期 12 ·1329-1334 · IF 1.872

A Highly Selective and Sensitive Fluorescent Probe Recognition for Co2+ in Aqueous Media Based on 8-Hydroxyquinolin-2-carbaldehyde-2-pyridylformylhydrazone Derivative

Keli Zhong,Jie Zhao,Xue Zhou,Shuhua Hou,Yanjiang Bian,Jianrong Li,Lijun Tang

A new (8-hydroxyquinolin-2-yl)methylene picolinohydrazide derivative ( L ) has been successfully synthesized and characterized. The probe L displays high selectivity to Co 2+ in CH 3 CN/HEPES (1:1, V / V , 10 mmol·L −1 , pH=7.4) with a fluorescence "ON-OFF" response. The Co 2+ ion recognition event possesses some distinct features including rapid response, high selectivity and sensitivity, good anti-interference ability and being applicable within a wide pH range. Based on job's plot and ESI-MS studies, the 1:1 binding mode was proposed. The binding constant of L and Co 2+ is 1.63×10 8 L·mol −1 and the detection limit is 1.15 µmol·L −1 . Natural water samples experiments revealed that probe L can be potentially applied to the detection of Co 2+ in real environment.

研究领域: 分析化学 · 生物无机化学 · 分子探针 · 环境监测 · 荧光传感
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF LUMINESCENCE · 2021 · IF 3.599

High-sensitivity based on Eu2+/Cr3+ co-doped BaAl12O19 phosphors for dual-mode optical thermometry

Yanting Zhu,Chenxia Li,Degang Deng,Hua Yu,Hao Li,Le Wang,Changyu Shen,Xufeng Jing,Shiqing Xu

A series of Eu 2+ /Cr 3+ co-doped BaAl 12 O 19 phosphor was synthesized by traditional high temperature solid stated method, and the temperature-sensitive characteristic of the phosphor was researched. Due to the temperature sensitivity of the fluorescence lifetime of Cr 3+ , the thermometry based on fluorescence lifetime can be realized. Furthermore, the emissions of Eu 2+ ion and Cr 3+ ion can be well separated, which shows the excellent signal recognition ability of this phosphor. The Eu 2+ /Cr 3+ co-doped BaAl 12 O 19 phosphor can be used for the thermometry based on fluorescence intensity ratio. A dual-mode optical thermometry is proposed and researched in the temperature range of 293–563 K by using the decay lifetime of Cr 3+ emission and in the temperature range of 295–476 K by using the fluorescence intensity ratio of Eu 2+ to Cr 3+ as temperature readout. The maximum values of relative sensitivity are 0.466% K −1 at 363 K and 0.259% K −1 at 476 K. The Eu 2+ /Cr 3+ co-doped BaAl 12 O 19 phosphor has excellent optical temperature characteristic , and its dual-mode thermometry characteristics provide convenience for the application of this material. This phosphor has potential application prospects in the field of optical thermometry.

研究领域: 材料科学 · 光学工程 · 无机化学 · 传感器技术 · 功能材料
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Journal of Analytical Science and Technology · 2021 ·Vol. 12 ·期 1 ·18 · IF 2.769

A highly sensitive fluorescent probe for ozone based on coumarin-benzothiazole derivative

Chen Kangni,Li Yanbo,Shang Jinyan,Zhao Chao,Li Heping

Ozone is widely used in daily life, but studies have shown that O 3 can damage human trachea and lungs, leading to diseases such as asthma, emphysema, and bronchitis. Therefore, it is of great significance to develop a simple and efficient detection method for monitoring O 3 in living cells. In this study, 3-(but-3-en-1-yl)-2-(7-(but-3-en-1-yloxy)-2-oxo-2H-chromen-3-yl)benzo[d]thiazol-3-ium (BCT) as a new type of water-soluble fluorescent probe was synthesized by substitution reaction of 4-bromo-1-butene and hydroxycoumarin-benzothiazole derivatives, which can specifically detect ozone in aqueous solution. The interaction of ozone on the probe can be completed within 20 min, the fluorescence intensity is significantly enhanced, and it has the advantages of high sensitivity (detection limit LOD = 43 nM). The influence of pH on the fluorescent performance of BCT shows that the probe with super stability under weak alkali and acidic environment, which provides the necessary conditions for its detection of ozone in physiological system detection. Therefore, BCT is expected to become an effective tool for detecting ozone in cellular organisms.

研究领域: 分析化学 · 分子生物学 · 环境毒理学 · 生物医学工程 · 细胞生物学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
APPLIED SURFACE SCIENCE · 2019 · IF 5.155

Long-range ordered silver nanoflower array structure for surface enhanced Raman scattering detecting

Dan Wu,Mengnan Hu,Yongyi Zhang,Jing Zhou,Zhaona Wang

Surface enhanced Raman spectroscopy (SERS) is a key nondestructive detecting technology with a broad application demands. However, relative low stability and homogeneity of the SERS substrate hinder its practical applications. Here, a simple and flexible approach is proposed to achieve the arrayed SERS substrates with the periodicity and local randomness by directly growing silver nanoflowers on the patterned wafer fabricated by the optical interference method. By utilizing the hotspot effect of nanogaps within/between the Ag nanoflowers, the SERS substrates demonstrate the low detecting limit of 5 × 10 −10  M and 5 × 10 −9  M in one-dimensional (1D) and two-dimensional (2D) pattern structures for Rhodamine 6G (R6G) probe molecule, respectively. The periodicity assures the fabricated substrate a promising reproducibility and stability. After the 1D array structure is left for 21 days, the intensity of Raman signal of R6G maintains at 80%. Moreover, the proposed method has the advantages of simple preparation, low cost, flexible tunability, and easy-fabrication large scale substrate. The results indicate that the long-range ordered silver nanoflower array structures are promising candidates for the high performance SERS substrate in chemical analysis, medicine and environment monitoring.

研究领域: 分析化学 · 纳米生物技术 · 材料科学 · 环境监测 · 医学检测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Theranostics · 2019 · IF 8.063

An innovative “unlocked mechanism” by a double key avenue for one-pot detection of microRNA-21 and microRNA-141

Weipan Peng,Qian Zhao,Minghui Chen,Jiafang Piao,Weichen Gao,Xiaoqun Gong,Jin Chang

The accurate and quantitative detection of microRNAs (miRNAs) as next-generation, reliable biomarkers will provide vital information for cancer research and treatment. However, their unique, intrinsic features pose quite a challenge for miRNA profiling, especially for multiplexed detection. Thus, there is a strong and an ever-growing need to develop an accurate, simple, sensitive and specific miRNA sensing method. Methods: In this study, a simple and novel sensor is presented that uses a flow cytometry (FCM) method based on the double key “unlocked mechanism” and a fluorescence enrichment signal amplification strategy. The “unlocked mechanism” was cleverly designed via using hairpin DNA probes (HDs) labeled by fluorescent particles (FS) as the lock to block part of them, which can specifically hybridize with the probe on polystyrene microparticles (PS). The target miRNA and duplex-specific nuclease (DSN) forming the double key can specifically open the HDs and cleave a single-stranded DNA (ssDNA) into DNA/RNA dimers circularly in order to unlock the special part of the HDs to be specially enriched further on the PS. Results: The designed sensor with a hairpin structure and DSN special performance was found to have a high specificity. The circularly unlocking fluorescent probes and fluorescent signal enrichment can be beneficial for achieving a high sensitivity with a detection limit of 3.39 fM for miRNA-21. Meanwhile, the performance of multiplexing was estimated by simultaneous detection of miR-21 and miR-141, and the method also allowed for miR-21 detection in breast cancer blood samples. Conclusion: The designed sensor based on an “unlocked mechanism” and a signal enrichment strategy resulted in a one-pot, highly specific and sensitive detection of multiplex miRNAs. The whole detection without the need for a complex purification process is based on a FCM and is expected to have a great value in cancer diagnosis and biomedical research.

研究领域: 生物标志物检测 · 癌症研究 · 生物医学工程 · 分子生物学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING · 2023 ·Vol. 129 ·期 10 ·682 · IF 2.7

MXene@CTAB@CMF three-dimensional elastic base for piezoresistive pressure sensors realized by electrostatic self-assembly

Yin Chunmei,Li Qinghua,Lu Zhiyi,Shi Yaochen,Lin Wei

A highly sensitive pressure-sensitive sensor based on MXene was developed using the electrostatic self-assembly method, with carbide sponges as the elastic substrate and a rational design. Specifically, CTAB was used to treat the carbide triamine sponge and conduct the electrostatic self-assembly with MXene to achieve a tightly combined conductive filler and substrate. The resulting pressure sensor showed excellent performance, with a high sensitivity of 15.05 kPa −1 under a range of 0–20 kPa, a response time of 0.1 s, and high durability under 2000 loading–unloading cycles. The minimum detection limit of the sensor was as low as 0.3 Pa, demonstrating excellent monitoring performance. Additionally, finite-element simulation analysis showed that MXene@CTAB@CMF had even better sensing performance at the same stress level. Moreover, the pressure sensor exhibited good sensing performance for various physiological signals and daily work monitoring of the human body, indicating its potential application value.

研究领域: 生物医学工程 · 纳米医学 · 柔性电子学 · 传感技术 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2019 · IF 6.361

Core-sheath nanofiber yarn for textile pressure sensor with high pressure sensitivity and spatial tactile acuity

Kun Qi,Hongbo Wang,Xiaolu You,Xuejiao Tao,Mengying Li,Yuman Zhou,Yimin Zhang,Jianxin He,Weili Shao,Shizhong Cui

Highly sensitive wearable textile pressure sensors represent the key components of smart textiles and personalized electronics, with potential applications in biomedical monitoring, electronic skin, and human-machine interfacing. Here, we present a simple and low-cost strategy to fabricate highly sensitive wearable textile pressure sensors for non-invasive human motion and physiological signal monitoring and the detection of dynamic tactile stimuli. The wearable textile sensor was woven using a one-dimensional (1D) weavable core-sheath nanofiber yarn, which was obtained by coating a Ni-coated cotton yarn electrode with carbon nanotube (CNT)-embedded polyurethane (PU) nanofibers using a simple electrospinning technique . In our design, the three-dimensional elastic porous nanofiber structure of the force-sensing layer and hierarchical fiber-bundled structure of the conductive Ni-coated electrode provide the sensor with a relatively large surface area, and a sufficient surface roughness and elasticity. This leads to rapid and sharp increases in the contact area under stimuli with low external pressure. As a result, the textile pressure sensor exhibits the advantages of a high sensitivity (16.52 N −1 ), wide sensing range (0.003–5 N), and short response time (~0.03 s). Owing to these merits, our textile-based sensor can be directly attached to the skin as usual and conformally fit the shape deformations of the body’s complex flexible curved surfaces. This contributes to the reliable real-time monitoring of human movements, ranging from subtle physiological signals to vigorous movements. Moreover, a large-area textile sensing matrix is successfully fabricated for tactile mapping of spatial pressure by being worn on the surface of wrist, highlighting the tremendous potential for applications in smart textiles and wearable electronics .

研究领域: 生物医学工程 · 柔性电子学 · 智能纺织品 · 可穿戴传感器 · 人机交互 · 转化医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Advanced Materials Technologies · 2019 ·Vol. 4 ·期 9 ·1900414 · IF 5.395

High Sensitivity and Broad Range Flexible Pressure Sensor Using Multilayered Porous PDMS/AgNP Sponge

Shuai Zhao,Rong Zhu

Flexible pressure sensors attract wide attentions in recent years for their significant applications in wearable electronics and health monitoring. It is strongly desired that a pressure sensor possesses both low detection limit and wide measuring capability, covering a broad pressure range from Pa to hundred kPa, to meet diverse demands in different applications. This paper proposes a novel flexible pressure sensor based on thermosensation, using a multilayered and graded-porosity polydimethylsiloxane/silver nanoparticle sponge as piezo-thermic transduction. The sensor exhibits a high sensitivity, a low detection limit of 4.1 Pa, and a wide measuring range up to 200 kPa, which leads to a high range-to-limit ratio of about 50 000. The pressure sensor is monolithically integrated with a temperature sensor and dissolves temperature-compensation. The unique combination of properties makes it feasible to monitor various human signals from subtle wrist pulse to finger tapping pressure and foot stepping pressure by a single device, which shows competent capabilities for multifarious applications in wearable electronics and health monitoring.

研究领域: 生物医学工程 · 传感器技术 · 可穿戴设备 · 健康监测 · 柔性电子 · 转化医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CERAMICS INTERNATIONAL · 2022 ·Vol. 49 ·期 5 ·7913-7919 · IF 5.532

Ultra-sensitive low-temperature thermometer regulated by the crystal field strength

Rui Li,Panlai Li,Guohui Wei,Jiehong Li,Yawei Shi,Ye Wang,Shaoxuan He,Yuanbo Yang,Wenge Ding,Zhijun Wang

Developing novel optical thermometry with ultrahigh relative sensitivity and temperature resolution has become a cutting-edge topic. For this purpose, under obeying Boltzmann distribution , a series of Li 2 Zn 0.9992-x A x Ge 3-y B y O 8 :0.08% Cr 3+ (B= Sc 3+ , In 3+ , A = Si 4+ ) phosphors were studied, which the luminescence intensity ratio between the transition of 4 T 2g → 4 A 2g emission and the R line based on thermally coupled energy levels constitutes a temperature sensing work with a relative sensitivity of 9.46% K −1 , 9.73% K −1 , and 10.38% K −1 , respectively. It is worth mentioning that the luminescence intensity of the R line (peak 1) increases significantly with the increase of temperature, while the transition of 4 T 2g → 4 A 2g (peak 2) with high intensity at low temperature gradually quenching, and this opposite trend is an important advantage for the design of excellent thermometers. Compared the best relative sensitivity of Li 2 Zn 0.9992-x A x Ge 3-y B y O 8 :0.08%Cr 3+ (B= Sc 3+ , In 3+ , A = Si 4+ ) with the crystal field Dq /B, it can be concluded that relative sensitivity increasing gradually with decreasing the intensity of crystal field. Finally, by testing the stability of the sample at 50 K, a thermal resolution of 0.082 K, 0.080 K and 0.077 K was obtained, respectively, which is one of the best thermal resolutions so far, while the repeatability of the sample stability at 50 K and 300 K cycles was higher than 99%. Our work is expected to provide guiding insights for optimizing the sensitivity of Cr 3+ -based luminescence intensity ratio thermometers.

研究领域: 材料科学 · 光学传感 · 固体物理 · 低温物理学 · 功能材料 · 发光材料
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。