转座酶法二代测序快速DNA建库试剂盒 (Illumina,50 ng)

货号: N665730
有货
★
规格
库存
价格
数量
24T
N665730-24T
期货 Stock Image
¥8,832.90
96T
N665730-96T
期货 Stock Image
¥34,497.90
请输入您要添加的产品数量
🧪
为什么选择此级别

,适用于对基线干扰要求严格的色谱和分析工作流程。

🌡

储存与运输

-20°C储存,避免反复冻融。超低温运输 。请查阅批次 COA 获取详细规格。

📋

质量文档

SDS、COA、产品数据表及规格说明书均可下载。可通过批号查询获取批次 COA。

📚

文献证明

在色谱分析、有机合成和交叉偶联反应领域已被 0 篇同行评审文献引用。

概述

产品内容 

N665730Component24 T96 TStorage
N665730ATPS V50    144 μL576 μL-20℃. Avoid freeze/thaw cycle.
N665730B5×FA Reaction Buffer144 μL576 μL-20℃. Avoid freeze/thaw cycle.
N665730C2×HiFidelity PCR Mix600 μL2×1.2 mL-20℃. Avoid freeze/thaw cycle.
N665730DPPM48 μL192 μL-20℃. Avoid freeze/thaw cycle.

* 本试剂盒适用于人基因组DNA文库构建,起始模板DNA投入量为50 ng。本公司还有 针对5 ng和1 ng的人基因组DNA起始的转座酶法文库构建试 剂盒,为得到质量较高的文库,不同的DNA起始量建议使用不同的试剂盒。 

产品简介 

该试剂盒是针对Illumina高通量测序平台定向开发的专用试剂盒,提供了基因组 DNA文库构建所需要的酶预混体系及反应缓冲液,包含除PCR引物外的所有成分。和 传统文库构建试剂盒相比,该试剂盒采用新型转座酶法进行文库构建,可以将DNA片 段化、末端修复及接头连接反应通过一步简单的酶促反应完成,显著降低了模板的使 用量,减少了实验操作步骤,缩短了文库构建时间;采用高保真DNA聚合酶进行文库 富集,无偏好的PCR扩增,扩大了序列的覆盖区域,可高效制备用于Illumina二代测序 平台的DNA文库。该试剂盒适用于起始模板DNA投入量为50 ng。试剂盒中所有试剂都 经过严格的质量控制和功能验证,最大程度上保证了文库构建的稳定性和重复性。

产品特点  

● DNA片段化、接头连接一步完成。 ● 超保真扩增,最大程度上降低了扩增偏好性。

 自备仪器试剂盒耗材

1. 磁力架:建议使用DynaMagTM-2。 

2. DNA纯化回收试剂盒:建议使用磁珠法DNA纯化回收试剂盒。 

3. 文库PCR引物试剂盒:建议使用转座酶法二代测序多样本引物试剂盒。 

4. 无水乙醇,去离子水(pH 在7.0-8.0之间)。 

5. 反应管:建议使用低吸附的PCR管与1.5 ml离心管。 枪头:建议使用高质量过滤枪头防止试剂盒、文库样本污染。

实验前准备及重要注意事项  

1.避免试剂的反复冻融。 

2.PCR产物因操作不当极易产生污染,导致实验结果不准确,建议将PCR反应体系 配制区与PCR产物纯化区隔离,并使用专门的移液器,定时对各实验区域进行清 洁。 

3.磁珠纯化:磁珠使用前应平衡至室温,磁珠的所有操作都应在室温下进行,80% 乙醇应现配现用,磁珠漂洗后干燥至表面无液体反光且呈磨砂状,磁珠干燥不足 会有乙醇残留影响后续实验,磁珠过度干燥影响DNA回收效率。 

4.该试剂盒适合人基因组DNA文库构建,如DNA样品为PCR产物,应保证其长度> 500 bp,由于转座酶无法作用于DNA末端,推荐在制备PCR产物时将PCR产物两 末端各延长50-100 bp,以避免出现末端测序覆盖度低的情况。

样品准备  

DNA纯度要求:A260/A280 = 1.8-2.0。 样本DNA:溶解于超纯水中。 DNA定量:DNA投入量过多、过少都会对文库质量有影响,建议先使用Nano检测基因 组DNA纯度再用Qubit对基因组进行浓度检测(请勿使用任何基于吸光度测量为基础的 测定方法进行模板定量)。 

DNA建库流程示意图

 

操作步骤

DNA片段化、接头连接反应

1. 向200 μl PCR管中加入以下试剂: 

组分

体积

50 ng DNA

X μl

TPS V50

6 μl

5×FA Reaction Buffer

6 μl

ddH2O

To 30 μl

2.用移液器轻轻吹打混匀,短暂离心,使所有组分收集到管底。

3. 将上述PCR管置于PCR仪中,热盖打开, 反应程序如下:

 

温度

时间

105℃

热盖

55℃

10 min

10℃

Hold

DNA在进行片段化反应完成后,转座酶仍处于较高的活性状态,应立即进行纯化, 以防止DNA过度片段化导致的文库片段变小。 

片段化产物纯化

  建议使用磁珠法DNA纯化回收试剂盒。

1.CMPure使用前应震荡混匀后置于室温平衡30 min。 

2.向片段化产物中加入50μl平衡至室温的磁珠,涡旋震荡5秒钟后,室温静置5分钟。

3. 置短暂离心,将离心管置于磁力架上,使磁珠和上清溶液分离,直至溶液澄清(约 需3-5分钟),小心吸取上清并弃除,期间避免接触已结合目标DNA的磁珠。 注意:不要弃除磁珠。 

4.继续保持离心管固定于磁力架上,向离心管中加入200 μl新鲜配置的80%乙醇,室 温放置30秒,小心弃除上清。 

注意:加乙醇时,液体不可直接吹打到磁珠上。

5.重复步骤4。 

6.保持离心管固定于磁力架上,室温静置干燥至磁珠表面微裂,加入23 μlddH2 O回溶。 

注意:不要使磁珠过度干燥,以免影响洗脱效率。 

7.将离心管从磁力架上取下,涡旋振荡使磁珠完全重悬,室温静置5分钟。短暂离心, 将离心管放于磁力架上直至溶液澄清,转移21 μl上清至一个新的200 μl PCR管中。

 PCR扩增

  1. 向200 μl PCR管中加入以下试剂: 

组分

体积

片段化产物

21 μl

PPM

2 μl

Primer N5

1 μl

Primer N7

1 μl

2×HiFidelity PCR Mix

25 μl

2.用移液器轻轻吹打混匀,短暂离心,使所有组分收集到管底。 

3.将上述PCR管置于PCR仪中,热盖打开, 反应程序如下:

 

步骤 延

温度

时间

 

延伸

72℃

3 min

 

预变性

98℃

30 s

 

  变性

98℃

15 s

5-10个循环

退火

60℃

30 s

5-10个循环

延伸

72℃

3 min

5-10个循环

终延伸

72℃

5 min

 

  保存

4℃

Hold


文库DNA片段选择性回收

  建议使用康为世纪磁珠法DNA纯化回收试剂盒进行DNA片 段选择性回收。需要不同大小DNA片段时,磁珠使用量不同,具体磁珠使用量参照附 表(若使用其他品牌磁珠,需自行摸索最佳磁珠用量)。 

注意:扩增产物也可使用胶回收试剂盒进行片段长度分选和纯化。如对文库长度分布范围无特殊 要求,扩增产物也可不进行DNA片段选择性回收,参考说明书第6页直接进行文库DNA片段的纯化。

1.CMPure使用前应震荡混匀后置于室温平衡30 min。 

2.PCR产物转移至1.5 ml离心管中,补水至100 μl加入若干体积平衡至室温的磁珠, 涡旋震荡5秒钟后,室温静置5分钟。 

3.短暂离心,将离心管置于磁力架上,使磁珠和上清分离,直至溶液澄清,小心吸 取上清转移至一新的1.5 ml离心管中。 注意:不要弃除上清。

4.在上清中加入若干体积的磁珠,涡旋震荡5秒钟后,室温静置5分钟。 

5.短暂离心,将离心管置于磁力架上,使磁珠和上清分离,直至溶液澄清,小心吸 取上清并弃除,期间避免接触已结合目标DNA的磁珠。 注意:不要弃除磁珠。

6.继续保持离心管固定于磁力架上,向离心管中加入200 μl新鲜配置的80%乙醇,室 温放置30秒,小心弃除上清。 注意:加乙醇时,液体不可直接吹打到磁珠上。 

7.重复步骤6一次。 

8.保持离心管固定于磁力架上,室温静置干燥至磁珠表面微裂,加入20 μl ddH2 O回溶。 注意:不要使磁珠过度干燥,以免影响洗脱效率。 

9.将离心管从磁力架上取下,涡旋振荡使磁珠完全重悬,室温静置5分钟。短暂离 心,将离心管放于磁力架上直至溶液澄清,将上清溶液转移至一个新的离心管中。  

附表:不同片段选择回收时磁珠建议用量 

DNA文库大小

插入片段

230 bp

330 bp

430 bp

DNA文库大小

(插入片段+adaptor+primer)

350 bp

450 bp

550 bp

磁珠用量

第一次选择

65 μl

55 μl

45 μl

磁珠用量

第二次选择

50 μl

30 μl

30 μl

文库DNA片段纯化 

建议使用康为世纪磁珠法DNA纯化回收试剂盒。 

1.CMPure使用前应震荡混匀后置于室温平衡30 min。 

2.PCR产物中加入50 μl平衡至室温的磁珠,涡旋震荡5秒钟后,室温静置5分钟。 

3.短暂离心,将离心管置于磁力架上,使磁珠和上清溶液分离,直至溶液澄清(约 需3-5分钟),小心吸取上清并弃除,期间避免接触已结合目标DNA的磁珠。 注意:不要弃除磁珠。 

4.继续保持离心管固定于磁力架上,向离心管中加入200 μl新鲜配置的80%乙醇,室 温放置30秒,小心弃除上清。 注意:加乙醇时,液体不可直接吹打到磁珠上。

5.重复步骤4。 

6.保持离心管固定于磁力架上,室温静置干燥至磁珠表面微裂,加入25 μl ddH2 O回溶。 注意:不要使磁珠过度干燥,以免影响洗脱效率。 

7.将离心管从磁力架上取下,涡旋振荡使磁珠完全重悬,室温静置5分钟。短暂离 心,将离心管放于磁力架上直至溶液澄清,将上清溶液转移至一个新的离心管中。

  文库质量检测

  文库浓度测定 

为了得到高质量的测序结果,需要对DNA文库进行精确定量,首先推荐使用Real-time PCR方法对DNA文库进行绝对定量。此外,还可使用荧光染料法,如Qubit法或荧光染 料picogreen法,此处请勿使用基于吸光度测量的定量方法。最终可使用以下近似公式 换算DNA文库的摩尔浓度。 

文库平均总长度

近似转换公式

300 bp

1 ng/μl=5.0 nM

400 bp

1 ng/μl=3.8 nM

500 bp

1 ng/μl=3.0 nM

文库片段分布 

制备好的DNA文库可用琼脂糖凝胶电泳或Agilent 2100 Bioanalyzer检测DNA文库中的 片段长度分布范围。 


Products content

N665730Component24 T96 TStorage
N665730ATPS V50    144 μL576 μL-20℃. Avoid freeze/thaw cycle.
N665730B5×FA Reaction Buffer144 μL576 μL-20℃. Avoid freeze/thaw cycle.
N665730C2×HiFidelity PCR Mix600 μL2×1.2 mL-20℃. Avoid freeze/thaw cycle.
N665730DPPM48 μL192 μL-20℃. Avoid freeze/thaw cycle.

* This kit is suitable for human genomic DNA library construction with a starting template DNA input of 50 ng. We also have transposase library construction kits for human genomic DNA starting at 5 ng and 1 ng, so it is recommended to use different kits for different starting amounts of DNA in order to obtain higher quality libraries.

 

Products Introduction

This kit is developed for Illumina's high-throughput sequencing platform and provides the enzyme premix system and reaction buffer for genomic DNA library construction, including all components except PCR primers. Compared with the traditional library construction kits, this kit adopts the new transposase method for library construction, which can complete DNA fragmentation, end repair and junction reaction in one simple enzymatic reaction, significantly reducing the amount of template, reducing the number of experimental steps, and shortening the time of library construction; it adopts the high-fidelity DNA polymerase for library enrichment, and the preference-free PCR amplification can expand the coverage area of the sequence, which can be used for efficient and effective sequencing. The use of high-fidelity DNA polymerase for library enrichment and preference-free PCR amplification broadens the coverage area of the sequence and enables efficient preparation of DNA libraries for Illumina's second-generation sequencing platform. The kit is suitable for DNA libraries with a starting template of 50 ng, and all reagents in the kit have been subjected to strict quality control and functional validation to maximize the stability and reproducibility of library construction.

 

Product Features

 

● DNA fragmentation and junction ligation in one step.

● Ultra-fidelity amplification minimizes amplification-preferred steps.

Provide your own instruments, kits and consumables

1. Magnetic frame: DynaMagTM-2 is recommended.

2. DNA purification and recovery kit: It is recommended to use  DNA purification and recovery kit by magnetic bead method.

3. Library PCR primer kits:  transposase method for second-generation sequencing multi-sample primer kits are recommended.

4. Anhydrous ethanol, deionized water (pH between 7.0 and 8.0).

5. Reaction tubes: It is recommended to use low adsorption PCR tubes and 1.5 ml centrifuge tubes. Tips: It is recommended to use high quality filter tips to prevent contamination of kits and library samples.

 

Pre-experiment Preparation and Important Notes

1. Avoid repeated freezing and thawing of reagents.

2. PCR products are easily contaminated due to improper operation, resulting in inaccurate results. It is recommended to isolate the PCR reaction system preparation area from the PCR product purification area, and to use special pipettes to clean the experimental areas at regular intervals.

3. Bead purification: the beads should be equilibrated to room temperature before use, all operations on the beads should be carried out at room temperature, 80% ethanol should be dispensed freshly, the beads should be rinsed and dried until the surface is free of liquid reflections and has a frosted appearance, insufficient drying of the beads will cause ethanol residue that will affect the subsequent experiments, and over-drying of the beads will affect the efficiency of DNA recovery.

4. The kit is suitable for human genomic DNA library construction, if the DNA sample is a PCR product, it should be ensured that its length>.

500 bp, since transposases do not work on DNA ends, it is recommended to extend the PCR product by 50-100 bp at each end of the PCR product to avoid low coverage of the ends for sequencing.

Sample Preparation

DNA purity requirements: A260/A280 = 1.8-2.0. Sample DNA: dissolve in ultrapure water. DNA Quantification: Too much or too little DNA will affect the quality of the library. It is recommended to use Nano to test the purity of the genomic DNA and then use Qubit to test the concentration of the genome (do not use any absorbance-based assay for template quantification).

Schematic diagram of DNA banking process


procedure

DNA fragmentation, junction reaction

1. Add the following reagents to a 200 μl PCR tube:

 

2. Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.

3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:


DNA should be purified immediately after the fragmentation reaction has been performed and the transposase is still in a high state of activity.

to prevent smaller library fragments due to DNA over-fragmentation.

 

Purification of fragmentation products

We recommend the use of the  Century Magnetic Bead Method DNA Purification and Recovery Kit.

1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.

2. Add 50 μl of magnetic beads equilibrated to room temperature to the fragmentation product, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.

3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.

4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 μl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.

Note: When adding ethanol, the liquid must not be blown directly onto the beads.

5. Repeat step 4.

6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, then add 23 μlddH2O to solubilize.

Note: Do not over-dry the beads as this may affect the elution efficiency.

7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer 21 μl of supernatant to a new 200 μl PCR tube.

PCR amplification

  Add the following reagents to the 200 μl PCR tube:

 Mix by gently blowing with a pipette and centrifuge briefly so that all components are collected at the bottom of the tube.

3. Place the above PCR tubes in the PCR instrument with the hot cap on and program the reaction as follows:

Selective recovery of library DNA fragments

It is recommended to use CombiVision Magnetic Beads DNA Purification and Recovery Kit for selective recovery of DNA fragments. When different sizes of DNA fragments are required, the amount of magnetic beads to be used is different, please refer to the attached table for the specific amount of magnetic beads to be used (if other brands of magnetic beads are used, you need to find out the optimal amount of magnetic beads to be used on your own).

Note: Amplification products can also be fragment length sorted and purified using the Gum Recovery Kit. If there is no special requirement for library length distribution, the amplification products can also be purified without selective recovery of DNA fragments as described on page 6 of the manual.

1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.

2. Transfer the PCR product to a 1.5 ml centrifuge tube, rehydrate to 100 μl and add several volumes of magnetic beads equilibrated to room temperature, vortex for 5 seconds and let stand at room temperature for 5 minutes.

3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, and carefully aspirate the supernatant and transfer it to a new 1.5 ml centrifuge tube.

Note: Do not discard the top clear.

4. Add several volumes of magnetic beads to the supernatant, vortex and shake for 5 seconds, then let stand at room temperature for 5 minutes.

5. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant until the solution is clear, carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA.

Note: Do not discard the beads.

6. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 μl of freshly prepared 80% ethanol to the tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.

Note: When adding ethanol, the liquid must not be blown directly onto the beads.

7. Repeat step 6 once.

8. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 20 μl of ddH2O to solubilize.

Note: Do not over-dry the beads as this may affect the elution efficiency.

9. Remove the centrifuge tube from the magnetic rack, vortex and oscillate to completely resuspend the beads, and let stand at room temperature for 5 minutes. Leave briefly

centrifuge, place the tube on a magnetic rack until the solution is clear, and transfer the supernatant solution to a new centrifuge tube.

 

 

Table: Suggested amount of magnetic beads for different segment selection recovery

Library DNA fragment purification

We recommend the use of the  Century Magnetic Bead Method DNA Purification and Recovery Kit.

1. CMPure should be equilibrated at room temperature for 30 min after shaking and mixing before use.

2. 50 μl of magnetic beads equilibrated to room temperature were added to the PCR product, vortexed and shaken for 5 seconds, and then left to stand at room temperature for 5 minutes.

3. Centrifuge briefly, place the tube on a magnetic rack to separate the beads from the supernatant solution until the solution is clear (approximately 3-5 minutes), carefully aspirate the supernatant and discard it, avoiding contact with the beads that have bound the target DNA. Note: Do not discard the beads.

4. Continue to keep the centrifuge tube fixed on a magnetic rack and add 200 μl of freshly prepared 80% ethanol to the centrifuge tube and allow to stand at room temperature for 30 seconds, carefully discarding the supernatant.

Note: When adding ethanol, the liquid must not be blown directly onto the beads.

5. Repeat step 4.

6. Keep the centrifuge tube fixed on a magnetic rack and leave to dry at room temperature until the surface of the beads is slightly cracked, add 25 μl of ddH2O to solubilize.

Note: Do not over-dry the beads as this may affect the elution efficiency.

7. Remove the tube from the magnetic rack, vortex to completely resuspend the beads, and allow to stand at room temperature for 5 minutes. Centrifuge briefly, place the tube on the magnetic rack until the solution is clear, and transfer the supernatant solution to a new tube.

Library quality control

Determination of library concentration

In order to obtain high-quality sequencing results, accurate quantification of DNA libraries is required, and the first recommendation is to use Real-time

PCR methods are used for absolute quantification of DNA libraries. Additionally, fluorescent dye methods such as the Qubit method or the fluorescent dye picogreen method can be used; do not use quantification methods based on absorbance measurements here. The following approximate formula can be used to convert the molar concentration of the DNA library.

 

Average total length of libraries

Approximate conversion formula

 

Library fragment distribution

The prepared DNA libraries can be detected by agarose gel electrophoresis or Agilent 2100 Bioanalyzer.

Range of segment length distributions.

 


规格

英文名称
NGS TPH DNA Library Prep Set for Illumina (50 ng)
储存与运输
储存条件
-20°C储存,避免反复冻融
运输条件
超低温运输

技术文档

📋 安全数据表 (SDS)

全面的危险、操作、储存及法规合规文件。

下载 SDS →

✅ 分析证书 (COA)

批次质量数据。输入批号以获取对应 COA。

查询 COA →

📊 产品数据表

产品规格和应用的快速参考摘要。

查看数据表 →

🔬 规格说明书

该级别的完整质量属性和验收标准。

查看规格说明 →

高级数据

质检证书(CoA,COO,BSE/TSE 和分析图谱)
C of A & Other Certificates(BSE/TSE, COO):
输入批号以搜索分析图谱:
技术文档和文章
溶液计算器

常见问题

本产品应如何储存?
请于?20 °C条件下保存。避免反复冻融。建议按单次用量分装保存。
本产品如何运输?
本产品采用保温箱配冰袋运输。收货后请立即拆包,并按上述储存条件保存。
如何获取批次专用COA?
每个订单都会随附分析证书(COA),您也可以从账户订单历史中下载。如需订购前的COA,请联系您的客户代表,或使用PDP上的"申请COA"按钮——我们将提供代表性批次的COA。