计算溶液所需的质量、体积或浓度。
罗丹明 123是一种可以通过细胞膜的选择性染色活细胞线粒体的荧光染料,呈黄绿色荧光,多用于检测线粒体膜电位,也常用于细胞凋亡检测。它可以快速通过细胞膜,仅需几分钟就可以被具有活性的线粒体所俘获,并且对细胞没有任何毒性罗丹明 123还用于对许多种细胞进行染色,包括植物细胞和细菌,由于细胞内 ATP 的量与罗丹明 123的荧光强度之间有相关性,因此罗丹明 123也被用于检测细胞内的 ATP。
操作步骤(仅供参考):
1、取对数生长期的细胞,将细胞密度调整到 3 × 10⁵ cells/mL接种至 6 孔板,培养 24 h,同时应设立阴性对照。
2、在各细胞中加入所需干预措施,继续培养一定时间后,收集细胞,PBS 清洗 2 次。
3、PBS 重悬细胞与 EP 管中,加入 1 μL罗丹明123溶液 (0.5mg/mL),避光孵育。
4、流式细胞仪 (激发波长 511 nm,发射波长 534 nm)或荧光显微镜下检测。
注意事项:
1、对于 6 孔板中的样品,本试剂共可以检测 100 个样品;对于 12 孔中的样品,本试剂共可以检测 200个样品 (100 μL包装)。
2、为了您的安全和健康,请穿实验服并戴一次性手套操作。
3、 本产品仅供科研使用,严禁它用。
Rhodamine 123 is a fluorescent dye that can selectively stain the mitochondria of living cells by passing through the cell membrane. It exhibits yellow-green fluorescence and is commonly used to detect mitochondrial membrane potential, and is also frequently used in apoptosis detection. It can rapidly pass through the cell membrane and be captured by active mitochondria within just a few minutes, without any toxicity to the cells. Rhodamine 123 is also used to stain many types of cells, including plant cells and bacteria. Because there is a correlation between the amount of intracellular ATP and the fluorescence intensity of Rhodamine 123, it is also used to detect intracellular ATP.
Procedure (for reference only):
1.Take cells in the logarithmic growth phase, adjust the cell density to 3 × 10⁵ cells/mL, and seed them into a 6-well plate. Culture for 24 h, and set up a negative control at the same time.
2.Add the required intervention measures to the cells. After continued culture for a certain period, collect the cells and wash twice with PBS.
3.Resuspend the cells in PBS in an EP tube, add 1 μL of Rhodamine 123 Solution (0.5 mg/mL), and incubate protected from light.
4.Detect using a flow cytometer (excitation wavelength 511 nm, emission wavelength 534 nm) or a fluorescence microscope.
Precautions:
1.For samples in a 6-well plate, this reagent can detect a total of 100 samples; for samples in a 12-well plate, this reagent can detect a total of 200 samples (100 μL package).
2.For your safety and health, please wear a laboratory coat and disposable gloves during operation.
3.This product is for research use only and strictly prohibited for other uses.
H302: 吞食有害
P501: 将内容物/容器送到批准的废物处理厂处理
P264: 处理后要彻底洗手。
P270: 使用本产品时,请勿进食、饮水或吸烟。
P330: 漱口
P301+P317: 如果被吞咽:请寻求医疗帮助。
我们的级别选择指南涵盖了目录中所有的变体的纯度、稳定剂状态和应用适用性。
查看 BioReagent 级别指南 → 查看 Biological Stain 级别指南 → 查看 for Fluorescence analysis 级别指南 →