文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数145个

设置提升方向
校准
KEY ENGINEERING MATERIALS · 2014 · IF 0

Simultaneous Determination of Pb2+ and Co2+ Based on Fluorescence Quenching of Bi-Color Quantum Dots with the Aid of Multivariate Calibration Techniques

Xin Feng Zhu,Jue Feng,Jun Wu Zhu,Bin Li,Qin Xu

Simultaneous determination of Pb2+ and Co2+ without separation has been successfully achieved by a bicolor quantumn dots mixture. This method takes advantage of the different degrees of the fluorescence quenching effects of Pb2+ and Co2+ to the bio-color quantum dots. Chemometrical approaches were applied to assist the discrimination and detection process. The construction of the multivariate calibration models, based on partial least squares (PLS), orthogonal projections to latent structures least squares (O-PLS) and kenel based orthogonal projections to latent structures (K-OPLS), allowed the simultaneous determination of Pb2+ (in the concentration range of 0-120 mM) and Co2+ (0-300 mM). The optimal number of factors in PLS and the optimal number of orthogonal components in O-PLS and K-OPLS were carefully selected. A comparison of prediction performances between these results was performed by relative prediction errors, square of the correlation coefficient and root mean squares error of prediction.

研究领域: 分析化学 · 生物医学工程
✓ 已验证 DOI
查看原文 查看 PubMed
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY · 2010 · IF 2.117

Determination of absolute photoionization cross-sections of oxygenated hydrocarbons

Mingfeng Xie,Zhongyue Zhou,Zhandong Wang,Dongna Chen,Fei Qi

The near-threshold absolute photoionization cross-sections of 12 oxygenated hydrocarbons, including 1-butanol, 2-butanol, iso -butanol, tert -butanol, 1-pentanol, tert -pentanol, iso -pentanol, methyl tert -butyl ether (MTBE), ethyl tert -butyl ether (ETBE), furan, 2-methylfuran, 2,5-dimethylfuran, were measured in the photon energy range from respective ionization thresholds to 11.5   eV. The experiments were performed with photoionization mass spectrometry and tunable synchrotron vacuum ultraviolet (VUV) light. Binary-liquid-mixtures of the investigated sample and benzene were used in the measurements where benzene acts as a calibration standard, due to its well known photoionization cross-section at the photon energies from its ionization energy (9.24   eV) to 11.5   eV. Photodissociative fragments from the molecules were also observed, and their photodissociation cross-sections are also presented.

CAS / MDL: 625-86-5 534-22-5
研究领域: 化学 · 物理化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
RAPID COMMUNICATIONS IN MASS SPECTROMETRY · 2010 ·Vol. 24 ·期 9 ·1335-1342 · IF 2.695

Determination of absolute photoionization cross-sections of alkanes and cyclo-alkanes

Zhongyue Zhou,Lidong Zhang,Mingfeng Xie,Zhandong Wang,Dongna Chen,Fei Qi

Absolute photoionization and dissociative photoionization cross-sections of eleven n- alkanes ( n- pentane, n -hexane, n- heptane, n- nonane, n- decane, n -undecane, n- dodecane, n- tridecane, n- tetradecane, n- pentadecane and n- hexadecane), three cyclo -alkanes (cyclopentane, methylcyclohexane and trans -decahydronaphthalene) and iso -octane were measured for photon energies from the ionization thresholds to 11.5 eV. The measurements were performed with the binary-liquid-mixture method utilizing the photoionization cross-sections of benzene as a calibration standard. The ionization energies of n -alkanes and cyclo -alkanes were also calculated at the B3P86/6-31 + +G(d,p) level and by the G3B3 method. Copyright © 2010 John Wiley & Sons, Ltd.

研究领域: 化学 · 物理化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
CERAMICS INTERNATIONAL · 2024 · IF 5.1

Exploring potential of quantum dots for high power solid-state lighting protected by transparent ceramics

Aochen Du,Hongxing Xie,Xingke Zheng,Jiaqi Gao,Xinyu Lin,Yun Ye,Enguo Chen,Sheng Xu,Tailiang Guo

For high power lighting, the protective role of transparent ceramics (TCs) on quantum dot diffusion plates (QDDPs) in preventing thermal damage is significant. The spectral, suitable for diverse lighting environments, can be precisely calibrated by modifying their ratio. The temperature dependent photoluminescence spectra, fluorescence lifetime, Huang Rhys factor and activation energy of TCs were studied in detail. It was evident from the results that the intensity of TCs remained above 89% even at 423 K, while fluorescence lifetime remained stable, nearly 64 ns? Huang-Rhys factor and activation energy were consistently measured at 1.81 and 0.13 eV, respectively. The extraordinary luminescent stability of TCs revealed their integral role in providing reliable protection for QDDPs. The spectra of LEDs/LDs were successfully predicted using Monte Carlo ray tracing method. The service condition under high-energy laser was studied using finite element method. White light with Commission Internationale de l'Eclairage (CIE) of (0.38, 0.39) and (0.31, 0.34) and luminous efficiency of 58 and 150 lm/W were prepared by combining QDDPs/TCs with LEDs/LDs, and the Color Rendering Index (CRI) reached a remarkable 88.4 and 78.8. A detailed exploration of the proficient thermal management was accomplished using finite element analysis, with the simulated outcomes matching closely with the experimental results.

研究领域: 材料科学 · 光学工程 · 照明技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY · 2018 ·Vol. 318 ·期 3 ·2307-2311 · IF 1.181

Preparation of reference sources for calibration of surface contamination monitors using Nafion ion exchange membrane

Chen Yanliang,Zhao Chao,He Linfeng,Tang Fangdong

A method was set up to prepare reference sources for calibration of surface contamination monitors using Nafion HP membrane to fix the radioactive nuclides on aluminium backing material. By investigating the adsorption mechanism including kinetics and pH, it has been proved the 241 Am could be fixed on the membrane effectively. The surface emission rate and the activity was measured to characterize the sources. In addition, the uniformity of the sources was evaluated according to ISO 8769 and the standard deviation of the surface emission rates from each individual portion of the whole source was no greater than 5%.

研究领域: 核技术 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS · 2017 · IF 2.303

Quantification of dopamine in biological samples by surface-enhanced Raman spectroscopy: Comparison of different calibration models

Cai-Xia Shi,Zeng-Ping Chen,Yao Chen,Qing Liu,Ru-Qin Yu

In this contribution, an attempt was made to quantify dopamine (DA) in complex biological samples (i.e., plasma and urine) using surface-enhanced Raman spectroscopy. Silver nanoparticles modified with iron-nitrilotriacetic acid (DA-selective probe) and 4-mercaptobenzoic acid (internal standard) were used as enhancing substrate. The performance of different calibration models for the quantification of DA in plasma and urine samples spiked with DA was evaluated and compared. The calibration models investigated were univariate ratiometric model based on the intensity ratio between the characteristic SERS peaks of DA and 4-mercaptobenzoic acid, PLS models built on the raw, standardized or pre-processed SERS measurements, and multiplicative effects model for surface-enhanced Raman spectroscopy (MEM SERS ). Experimental results showed that among the models considered in this contribution, only MEM SERS achieved quite accurate and precise concentration predictions for DA in the spiked plasma and urine samples with recovery rates varying within the range of 91.9–112%, surprisingly better than the corresponding values of the quantitative results obtained by LC-MS/MS. This work provided further evidence of the effectiveness of MEM SERS in solving the problem of poor accuracy of quantitative SERS assays.

研究领域: 分析化学 · 生物医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Nature Communications · 2025 ·Vol. 16 ·期 1 ·1-12 · IF 15.7

Sub-femtomolar drug monitoring via co-calibration mechanism with nanoconfined DNA probes

Chen Yonghuan,Li Xiuying,Yue Xinru,Yu Weihua,Shi Yuesen,He Zilong,Wang Yuanfeng,Huang Yu,Xia Fan,Li Fengyu

Synthetic drugs fundamentally reshape the illicit drug market due to their low cost, ease of production, and rapid manufacturing processes. However, current drug detection methods, which rely on complex instruments, have limited applicability and often neglect the influence of pH fluctuations, leading to potential bias and unreliable results. Herein, we propose co-calibration DNA probes on a nanoconfined biosensor (N C B S ), covering the range of sweat pH 3–8 to achieve significantly enhanced target signal recognition. The N C B S exhibits a linear response range of 10 3 -10 8 fM with a low limit of detection (LOD) of 3.58 fM in artificial sweat. Compared to the single-aptamer N C B S , the dual-aptamer N C B S offers a broader linear response range, primarily due to the synergistic effects of changes in surface wettability and the capture of hydrion, which together reduce signal interference in proton transport. The linear response range doubles, and its detection sensitivity improves by 4–5 orders of magnitude compared to existing drug detection methods. This sensing strategy expands the application scope of aptamer-based composite probes, offering an approach for ultra-sensitive drug detection and demonstrating significant potential in sweat sensing and drug monitoring fields.

CAS / MDL: 13822-56-5 69-65-8
研究领域: 生物传感 · 分析化学 · 药物检测
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2024 · IF 4.3

Quantification of antibiotics in food by octahedral gold-silver nanocages-based SERS sensor coupling multivariate calibration

Huanhuan Li,Wei Sheng,Md. Mehedi Hassan,Wenhui Geng,Quansheng Chen

The abuse of antibiotics has caused gradually increases drug-resistant bacterial strains that pose health risks. Herein, a sensitive SERS sensor coupled multivariate calibration was proposed for quantification of antibiotics in milk. Initially, octahedral gold-silver nanocages (Au@Ag MCs) were synthesized by Cu 2 O template etching method as SERS substrates, which enhanced the plasmonic effect through sharp edges and hollow nanostructures. Afterwards, five chemometric algorithms, like partial least square (PLS), uninformative variable elimination-PLS (UVE-PLS), competitive adaptive reweighted sampling-PLS (CARS-PLS), random frog-PLS (RF-PLS), and convolutional neural network (CNN) were applied for TTC and CAP . RF-PLS performed optimally for TTC and CAP (Rc = 0.9686, Rp = 0.9648, RPD = 3.79 for TTC and Rc = 0.9893, Rp = 0.9878, RPD = 5.88 for CAP). Furthermore, the detection limit of 0.0001 µg/mL for both TTC and CAP was obtained. Finally, satisfactory ( p  > 0.05) results were obtained with the standard HPLC method. Therefore, SERS combined RF-PLS could be applied for fast, nondestructive sensing of TTC and CAP in milk.

研究领域: 分析化学 · 食品科学 · 生物医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF THE AMERICAN CERAMIC SOCIETY · 2025 · IF 3.8

Multimodal self-calibrating photothermal window utilizing transparent Pr3+–Er3+ co-doped Y2Zr2O7 ceramics

Mengqiu Guan,Wenhan Han,Kailei Lu,Yuhong Xie,Zijie Li,Yucheng Ye,Guixin Wang,Jianqi Qi,Tiecheng Lu

In response to the urgent demand for windows with multi-mode self-calibrated temperature feedback operating over a wide range in extreme environments, herein, Pr 3+ –Er 3+ co-doped Y 2 Zr 2 O 7 (YZO) transparent ceramics were developed. After annealing treatment to remove defects, these ceramics exhibit high transparency and temperature-dependent wide-range photoluminescence, in which the in-line transmittance is up to 77.8% at 760 nm (theoretical limit is 78%), and the luminescence band spans blue to red. Furthermore, based on the luminescence intensity ratio technology, a multi-mode temperature sensing window using highly transparent YZO:Pr/Er ceramics was designed. The developed photothermal window shows relatively high sensitivity, in which absolute sensitivity ( S a ) and relative sensitivity ( S r ) reached 0.0105 K −1 at 363 K and 1.295% K −1 at 301 K, respectively. The developed thermometer could provide a reference for self-calibrated thermometer window, and its wide spectral operating range ensures the reliability of temperature measurement, which has the potential to be used in some extreme conditions.

CAS / MDL: 12061-16-4 12037-29-5
研究领域: 材料科学 · 光学工程 · 物理学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2013 · IF 3.535

Bienzyme colorimetric detection of glucose with self-calibration based on tree-shaped paper strip

Wen-Jie Zhu,Da-Qian Feng,Meng Chen,Zhi-Dong Chen,Rong Zhu,Hai-Lin Fang,Wei Wang

In this contribution, we first developed a semiquantitative method for the detection of glucose with self-calibration based on bienzyme colorimetry by using tree-shaped paper strip. The GOD/HRP bienzyme system was utilized to amplify the color signal in the aqueous phase. Moreover, we employed a paper as microfluidic media for running colorimetric assay, while tree-shaped paper strip was designed to ensure uniform microfluidic flow for multiple branches. Our proposed method gives direct outcomes which can be observed by the naked eye or recorded by a simple camera. The linear range is from 1.0   ×   10 −3 to 11.0   ×   10 −3   M, with a detection limit of 3   ×   10 −4   M. Furthermore, the effect of detection condition has been investigated and discussed comprehensively. The result of determining glucose in human serum is consistent with that of detecting standard glucose solution by using our developed approach. A low-cost, simple, and rapid colorimetric method for the simultaneous detection of glucose with self-calibration on the tree-shaped paper has been proposed.

CAS / MDL: 9003-99-0
研究领域: 分析化学 · 医学诊断
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2022 · IF 9.231

Rapid self-calibrating fluorescent detection of copper (II) ions in wine with high accuracy

Xiuxiu Dai,Zengqiang Liang,Yang Li,Jian Tao,Lingbo Qu,Linping Zhao,Ran Yang

Excessive copper in wine can cause formation of oxidation reactions and affect the quality of wine. Herein, a rapid self-calibrating fluorescence sensing system for the detection of copper (II) ions in wine was developed. The sensing system has a dual-emission peak of 480 nm and 550 nm at the excitation wavelength of 390 nm. Only the yellow fluorescence can be selectively quenched by copper (II) ions. In contrast, the blue fluorescence stays almost constant, resulting in the apparent change of fluorescence image from yellow to blue. The reaction can be completed within 8 s. The sensing system showed a good linear relationship with copper (II) ions concentration in 0–4 μmol/L, with a detection limit of 46.5 nmol/L. Based on this sensing system, a fluorescent dual-tube detection bottle was designed to detect copper (II) ions more conveniently and was successfully applied to detect copper (II) ions in wine.

CAS / MDL: 67-68-5
研究领域: 分析化学 · 食品科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF LUMINESCENCE · 2022 · IF 4.171

A highly sensitive blue-LED-excitable self-calibrated luminescent thermometer based on Cr3+/Eu3+ Co-doped Al2W3O12

Yiying Li,Wenwu You,Jun Zhao,Xiaomin Zhang,Gencai Pan,Yanli Mao

In this work, Al 2 W 3 O 12 :1%Cr 3+ ,2%Eu 3+ with two discriminable dual emissive centers is synthesized. Both Eu 3+ and Cr 3+ ions can be excited efficiently by 465 nm. Photoluminescence excitation (PLE) spectra and photoluminescence (PL) lifetime indicate that there is no energy transfer (ET) between Eu 3+ and Cr 3+ ions. It is worth noting that the photothermal stability of Eu 3+ ions is much better than that of Cr 3+ ions. Specifically, the ratio of I Cr /I Eu decreases linearly with increasing temperature. Therefore, a blue-LED-excitable luminescent thermometer based on Cr 3+ /Eu 3+ co-doped Al 2 W 3 O 12 is proposed. This developed self-calibrated luminescent temperature sensor possesses the relatively high absolute and relative sensitivity (0.38 K -1 and 2.9% K −1 respectively) as well as good cycle stability among the previously reported TM/Ln-based luminescent; thermometers. These superior features of the developed self-calibrated luminescent thermometer (SCLT) make it a very promising candidate for temperature sensing applications.

研究领域: 材料科学 · 光学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。