文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数713个

设置提升方向
比率荧光
Journal of Inorganic and Organometallic Polymers and Materials · 2019 ·Vol. 29 ·期 6 ·2124-2132 · IF 1.637

Eu3+/TFA Functionalized MOF as Luminescent Enhancement Platform: A Ratiometric Luminescent Sensor for Hydrogen Sulfide in Aqueous Solution

Wang Zirui,Wang Xinyu,Li Jingfang,Li Weizuo,Li Guangming

In this work, a facile and fast luminescence sensing platform for the ratiometric detection of hydrogen sulfide (H 2 S/HS − ) has been constructed by encapsulating the Eu 3+ /β-diketone chromophore into the host framework of MIL-140 (Eu 3+ /TFA@MIL-140C, TFA = 1,1,1-Trifluoro-2,4-pentanedione). It is well known that the energy transfer from the host framework or/and TFA to the Eu 3+ ions can be disturbed easily by some metal ions, such as Cu 2+ ions. Therefore, the ratiometric sensor was constituted with the Eu 3+ /β-diketone moiety as the response signal and the host framework moiety as the reference signal. Furthermore, on the basis of the hard–soft acid–base theory, the Cu 2+ ions could be rapidly caught by HS − , profiting from the low solubility of CuS, realizing the real-time detection by luminescence color change. This sensor shows remarkable property on the detection of H 2 S (HS − in water solution) with low limit of detection (LOD = 7.43 μM) and short response time (< 0.5 min). The good linearity between luminescent intensity and concentration makes the luminescent ratio meter feasible.

研究领域: 材料科学 · 分析化学 · 环境科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROPOROUS AND MESOPOROUS MATERIALS · 2022 · IF 5.876

Three-step post-synthetic modification metal-organic framework as a ratiometric fluorescent probe for the detection of creatinine

Ning Wu,Hao Guo,Liping Peng,Yuan Chen,Lei Sun,Yinsheng Liu,Xiaoqing Wei,Wu Yang

Creatinine (Cre) measurement in biological fluids is an increasingly important clinical measure for evaluating renal insufficiency, thyroid dysfunction, and muscle injury. Therefore, a simple, fast, and reliable Cre analysis method is of great significance to human health. Herein, a novel ratiometric fluorescence sensor, Ag-Eu-MOF-808-EDTA, was synthesized by introducing ethylenediaminetetraacetic acid (EDTA), Ag + , and Eu 3+ into the framework of MOF-808 through three steps of post-synthesis modification, and was used to detect Cre in PBS buffer of pH 7.2 at 35 °C with a “turn-on” ratio response in the presence of various interfering ions and several biomolecules. In this strategy, the characteristic emission of Eu 3+ at 551 nm can be turned on due to coordination between Cre and Ag + , while emission at 613 nm is independent of Cre, which produces a significant ratio response change throughout the cycle. Experimental results showed that the ratio fluorescence sensor displayed a wide linear range for Cre from 0.5 to 350 μM with a low detection limit of 0.42 μM. Finally, a good recovery rate (96.7–102.9%) and appropriate relative standard deviation (RSD <2.39%, n = 3) were obtained during the determination of creatinine in real urine and serum. This work provides additional insights into the detection of creatinine in clinical blood samples.

研究领域: 分析化学 · 生物医学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Environmental Sciences · 2024 · IF 5.9

Construction of eco-friendly dual carbon dots ratiometric fluorescence probe for highly selective and efficient sensing mercury ion

Yongli Liu,Xiaoyan Su,Huanjia Liu,Guifen Zhu,Guobei Ge,Yuxin Wang,Penghui Zhou,Qingxiang Zhou

In present work, blue carbon dots (b-CDs) were derived from ammonium citrate and guanidine hydrochloride, and red carbon dots (r-CDs) were stemmed from malonate, ethylenediamine and meso‑tetra (4-carboxyphenyl) porphin based on facile hydrothermal method . Eco-friendly ratiometric fluorescence probe was innovatively constructed to effectively measure Hg 2+ utilizing b-CDs and r-CDs. The developed probe displayed two typical emission peaks at 450 nm from b-CDs and 650 nm from r-CDs under the excitation at 360 nm. Mercury ion has strong quenching effect on the fluorescence intensity at 450 nm due to the electron transfer process and the fluorescence change at 450 nm was used as the response signal, whereas the fluorescence intensity at 650 nm kept unchangeable which resulted from the chemical inertness between Hg 2+ and r-CDs, serving as the reference signal in the sensing system. Under optimal circumstances, this probe exhibited an excellent linearity between the fluorescence response values of ΔF 450 /F 650 and Hg 2+ concentrations over range of 0.01–10 µmol/L, and the limit of detection was down to 5.3 nmol/L. Furthermore, this probe was successfully employed for sensing Hg 2+ in practical environmental water samples with satisfied recoveries of 98.5%–105.0%. The constructed ratiometric fluorescent probe provided a rapid, environmental-friendly, reliable, and efficient platform for measuring trace Hg 2+ in environmental field.

研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2024 · IF 10.7

CRISPR/Cas12a-derived ratiometric fluorescence sensor for high-sensitive Pb2+ detection based on CDs@ZIF-8 and DNAzyme

Chuanyu Yang,Caiyi Du,Feiyu Yuan,Peitong Yu,Boxu Wang,Changshun Su,Ruiqi Zou,Junyang Wang,Xu Yan,Chunyan Sun,Hongxia Li

Benefiting from specific target recognition and trans-cleavage capabilities, the CRISPR/Cas12a system has great application prospects in the design of highly sensitive and rapid fluorescence biosensors. The CRISPR/Cas12a-based fluorophore-quencher molecular beacons exhibit single-color emission and are easily exposed to interference from environmental factors. Herein, we design a CRISPR/Cas12a-derived ratiometric fluorescence sensor for Pb 2+ detection based on embedded carbon dots@zeolitic imidazolate framework-8 (CDs@ZIF-8) composites and DNAzyme. The functions of ZIF-8 about encapsulating red emissive CDs in the inner cavity and adsorbing DNA on the outer surface are integrated to establish dual fluorescence signals, thereby reducing the possibility of interference and improving sensing accuracy. The presence of Pb 2+ is converted into the change of activator by the GR5 DNAzyme to activate the CRISPR/Cas12a system, which provides signal amplification through multiple turnovers of side branch cutting, achieving highly sensitive detection of Pb 2+ with a low detection limit of 18 pM. This method has the advantages of simplicity, universality, and excellent quantitative ability, and has broad prospects in sensing applications.

研究领域: 生物传感 · 分子生物学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Nanoscale · 2019 ·Vol. 11 ·期 17 ·8458-8463 · IF 6.97

Lysosome-targeted carbon dots for ratiometric imaging of formaldehyde in living cells

Haifang Liu,Yuanqiang Sun,Zhaohui Li,Jie Yang,Aaron Albert Aryee,Lingbo Qu,Dan Du,Yuehe Lin

Formaldehyde (FA) is involved in many biological processes and is closely connected with many diseases including Alzheimer's disease and cancer. Therefore, methods for sensitive and selective detection of FA in living cells are highly demanded. As a new class of carbon nanomaterials, carbon dots (CDs) have attracted great attention owing to their robust photostability, good biocompatibility and environmental friendliness. In this manuscript, the first lysosome-targeted CDs for ratiometric fluorescence detection of FA were efficiently prepared from dexamethasone and 1,2,4,5-tetraaminobenzene through the microwave-assisted hydrothermal method. These CDs show highly selective and sensitive sensing ability towards FA with fast response and great changes of ratio values. The CDs exhibit robust photostability and good biocompatibility and were successfully employed in ratiometric fluorescence bioimaging of FA fluctuations in lysosomes of living cells, which demonstrates their great practicability in FA-related bioanalysis and biological studies.

研究领域: 生物化学 · 纳米医学 · 分析化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2025 ·Vol. 192 ·期 4 ·1-13 · IF 5.3

Ratiometric fluorescence quantification of folic acid utilizing D-penicillamine-based carbon dots in conjunction with glutathione S-transferase-Au nanoclusters

Zhou Mengyan,Zhang Zhihui,Zheng Qi,Yu Mingdi,Si Mengxu,Wu Sirui,Zhang Yanan,Ding Shushu,Fu Ding-Yi

A novel ratiometric fluorescent nanohybrid probe was constructed for sensitive and selective determination of folic acid (FA) based on blue D-penicillamine-based carbon dots (CDs) and red glutathione S-transferase-Au nanoclusters (GST-AuNCs). Upon the excitation of 380 nm, the obtained CDs-NCs possessed two distinct emission peaks at 465 and 665 nm. The fluorescence intensity at 465 nm was incrementally enhanced with the addition of FA attributed to the hydrogen bonds formation, while the fluorescence intensity at 665 nm was quenched caused by the electronic interaction and the inner filter effects. The fluorescence intensity ratio ( I 465 /I 665 ) exhibited good linear correlation with FA concentrations in the range 10∼90 μM, and the limit of detection (LOD) was 0.63 μM. Notably, the corresponding fluorescent color changed from red to blue, which could be distinguished by naked eyes. On account of the excellent biocompatibility, the CDs-NCs were further successfully used for bioimaging and intracellular FA detection. Furthermore, the real sample analyses confirmed that the proposed nanoprobe could be expanded as a versatile platform for FA detection in practical applications. Graphical abstract

研究领域: 分析化学 · 生物医学工程 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF FLUORESCENCE · 2025 · IF 3.1

Ratio Fluorescence Sensor Based on Bimetal MOFs for the Detection of Hg2+and H2O2

Han Bo-Ming,Zhang Hao-Rui,Gao Wen-Jie,He Xi-Wen,Li Wen-You,Zhang Yu-Kui

In this work, a dual-emission material based on lanthanide metals was synthesized and used as a ratio fluorescence sensor to respond to Hg 2+ and H 2 O 2 , respectively. Tb-BDC-NH 2 as a bimetal MOFs had double ligands and exhibited double fluorescence emission peaks at 550 nm and 450 nm. The two emission peaks of Tb-BDC-NH 2 can be quenched by Hg 2+ and H 2 O 2 respectively, forming a built-in calibration signal for ratio fluorescence detection. Based on the different detection conditions of the Hg 2+ and H 2 O 2 , the simultaneous detection of the two detection substances can be achieved with simple operation. This detection system had good stability and anti-interference ability. Under optimal conditions, the detection limit for Hg 2+ detection was 0.2 µM. Meanwhile, for the detection of H 2 O 2 , the detection limit was 11 µM and large linear ranges were obtained. Through actual sample testing, it had been proven that the ratio fluorescence sensor based on Tb-BDC-NH 2 had good application prospects. And the work also provided a new idea for double substances detection.

CAS / MDL: 64-17-5 68-12-2
研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2024 · IF 4.3

The novel up/down-conversion dual-emission carbon dots for dual-channel ratiometric fluorescence detection of pH and Cu2+

Yulin Zhu,Mengqi Zhu,Qiuju Zhou,Qunwei Shu,Kejun Tan

Up/down-conversion dual-emission carbon dots (U/D-CDs) are rare and have potential in analytical sensing. Herein, a kind of novel U/D-CDs was prepared successfully by a one-step solvothermal method. The prepared U/D-CDs exhibited similar dual-emission behaviors at excitation wavelengths of 300 nm and 680 nm, respectively. In addition, U/D-CDs displayed good photostability and salt-resistance. Due to the protonation-deprotonation, U/D-CDs showed strong pH dependence in the pH range of 2.0–8.0, which developed an up/down-conversion dual-channel ratiometric fluorescence (FL) probe of pH. The FL intensity of U/D-CDs can be effectively quenched by Cu 2+ through the static quenching effect. Meanwhile, an obvious color change from yellow-green to blue can be observed under ultraviolet light with the increase of Cu 2+ concentration. The up/down-conversion dual-channel ratiometric fluorescence sensor can be used for the visual sensing of pH and Cu 2+ , which also eliminates background signals and improves its accuracy and selectivity in complex samples.

研究领域: 分析化学 · 材料科学 · 环境科学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2020 ·Vol. 44 ·期 42 ·18389-18398 · IF 3.288

An endoplasmic reticulum-targeting and ratiometric fluorescent probe for hypochlorous acid in living cells based on a 1,8-naphthalimide derivative

Qiujuan Ma,Chunyan Wang,Guojiang Mao,Meiju Tian,Jingguo Sun,Suxiang Feng

As a key reactive oxygen species (ROS), hypochlorous acid (HClO) plays a vital role in living systems. Ratiometric and endoplasmic reticulum-targeting probes for highly sensitive detection of hypochlorous acid are in demand. In this paper, we constructed a novel reticulum-targeting and ratiometric fluorescent probe for determining hypochlorous acid. The probe applied 4-aminonaphthalimide as the fluorescent group, employed the (2-aminoethyl)thiourea group as a specific recognition unit, and used the p-toluenesulfonamide group as the localization group of the endoplasmic reticulum. When HClO is absent, the probe underwent an intramolecular charge transfer (ICT) process and displayed green emission. In the presence of HClO, the ICT process was inhibited, which induced a 49 nm blue-shift of fluorescence emission from 533 nm to 484 nm. The ratiometric fluorescent probe exhibited high sensitivity and selectivity for HClO. Furthermore, the ratiometric fluorescent probe could work in a wide pH range. The fluorescence intensity ratios (I484nm/I533nm) exhibited a linear response to the concentration of HClO from 5.0 × 10−7 to 1.0 × 10−5 mol L−1. The detection limit was evaluated to be 1.0 × 10−7 mol L−1 for HClO. In addition, the probe displayed an excellent endoplasmic reticulum-targeting ability, and has been successfully applied for the confocal imaging of HClO in the endoplasmic reticulum of PC-12 cells with almost no cell toxicity. All of such outstanding properties demonstrated that it could be employed to sense HClO in the endoplasmic reticulum of living cells.

CAS / MDL: 70-18-8
研究领域: 生物化学 · 细胞生物学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MOLECULES · 2019 ·Vol. 24 ·期 12 ·2278 · IF 3.06

Ratiometric Fluorescent Nanoprobe for Highly Sensitive Determination of Mercury Ions

Zhihui Luo,Hui Xu,Baogui Ning,ZeBin Guo,Na Li,Lina Chen,Guobao Huang,Charlie Li,Baodong Zheng

In this study, a novel dual-emission ratiometric fluorescent nanoprobe (RFN) was synthesized and ultilized for highly sensitive determination of mercury ions. In this nanoprobe, fluorescein isothiocyanate (FITC) doped silica (SiO2) served as a reference signal, FITC–SiO2microspheres were synthesized and modified with amino groups, and then Au Nanoclusters (AuNCs) were combined with the amino groups on the surface of the FITC–SiO2microspheres to obtain the RFN. The selectivity, stability, and pH of the RFN were then optimized, and the determination of mercury ions was performed under optimal conditions. The probe fluorescence intensity ratio (F520nm/F680nm) and Hg2+concentration (1.0 × 10−10mol/L to 1.0 × 10−8mol/L) showed a good linear relationship, with a correlation coefficient of R2= 0.98802 and a detection limit of 1.0 × 10−10mol/L, respectively. The probe was used for the determination of trace mercury ion in water samples, and the recovery rate was 98.15~100.45%, suggesting a wide range of applications in monitoring pollutants, such as heavy metal ion and in the area of environmental protection.Keywords:ratiometric fluorescent nanoprobe;dual-emission;mercury ions;determination

研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2020 ·Vol. 12 ·期 12 ·1617-1623 · IF 2.596

Carbon dots tailored with a fluorophore for sensitive and selective detection of hydrogen sulfide based on a ratiometric fluorescence signal

Guoqiang Liu,Hongwei Ge,Ranhao Yin,Long Yu,Congming Sun,Weiru Dong,Zhenli Sun,Khalid A. Alamry,Hadi M. Marwani,Suhua Wang

To discriminate hydrogen sulfide (H2S) from thiol nucleophiles with similar reactivity is always a major challenge in developing new detection methods. In this paper, we report a colorimetric and ratiometric fluorescence probe selectively reactive to H2S, which was synthesized by hybridizing the fluorescent nitro-benz-2-oxa-1,3-diazole (NBD)-based derivative P-NBD with carbon dots (CDs). The selective reaction can be monitored by distinct ratiometric fluorescence or colorimetric variation. The nanohybrid probe exhibited two fluorescence bands centered at 440 nm and 543 nm, respectively. The yellow fluorescence at 543 nm from P-NBD is quenched by H2S, while the blue fluorescence is enhanced by weakening of the Förster resonance energy transfer (FRET) mechanism. It was observed that the apparent fluorescence color evolved from yellow to blue when exposed to different amounts of H2S, accompanied by the color change of the probe solution from yellow to red under natural light. The detection limit was estimated to be 57 nM in aqueous solution. We successfully applied this probe for the detection of H2S in real water samples, suggesting its potential application in environmental monitoring and protection.

研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ECS Journal of Solid State Science and Technology · 2024 ·Vol. 13 ·期 5 ·057004 · IF 1.8

Fluorescein@NH2-UiO-66 Probe for Ratiometric Fluorescence Sensing of Trace Phosphate in Water

Yu Ding,Yaru Li,Soufian Chakir,Jun Mei,Xianbiao Wang

Phosphate pollution leads to deterioration in water quality, posing a serious threat to human health. Therefore, it is important to develop a highly selective and sensitive fluorescent probe for phosphate detection. Here, we report a novel ratiometric fluorescent probe, Fluorescein@NH2-UiO-66 (denoted as Flu@NH2-UiO-66), for the trace detection of phosphate in water. Specifically, during the in situ solvothermal synthesis of Flu@NH2-UiO-66, fluorescein molecules were encapsulated into the cavities of the metal-organic framework. Furthermore, the encapsulation amount of fluorescein was controlled by adjusting the acidity of the system. The Flu@NH2-UiO-66 (60 H+) sample, prepared with a 60:1 molar ratio of acetic acid to the metal center exhibited distinct dual fluorescence signal peaks. The probe showed a highly selective fluorescence response to phosphate. Within a range of 0–20 μM phosphate concentration, the probe demonstrated excellent linear detection capability with a detection limit of 0.37 μM. Moreover, the mechanism of fluorescence enhancement can be attributed to the addition of phosphate, which greatly increases the UV absorbance of the probe. This study developed a novel ratiometric fluorescent probe capable of rapid, sensitive, and stable detection of trace phosphate, which is of great significance for environmental management.

研究领域: 环境科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制