高灵敏TMB显色液(ELISA HRP显色用)

货号: H743375
有货
★
规格
库存
价格
数量
100ml
H743375-100ml
现货 Stock Image
¥266.90
500ml
H743375-500ml
期货 Stock Image
¥986.90
请输入您要添加的产品数量
🧪
为什么选择此级别

,适用于对基线干扰要求严格的色谱和分析工作流程。

🌡

储存与运输

2-8°C储存,避光。低温运输 。请查阅批次 COA 获取详细规格。

📋

质量文档

SDS、COA、产品数据表及规格说明书均可下载。可通过批号查询获取批次 COA。

📚

文献证明

在色谱分析、有机合成和交叉偶联反应领域已被 0 篇同行评审文献引用。

概述

阿拉丁该系统产品具有低本底、稳定、批间差小、不同灵敏度可选的特点,提供了优越的信号反应体系,适用于 ELISA 试剂盒的研发和生产应用。高灵敏TMB显色液具有高灵敏、低本底、稳定的特点,适用于显色时间2-15分钟的检测实验。

pH  值 pH value: 3.6±0.4 
防腐剂 Preservative: 0.0002%(w/v)异噻唑啉酮 
储   存 Storage: 2~8℃ 
应 用 Application: ELISA

应用说明:

本产品在使用前请平衡至反应温度。 

 显色步骤:

450nm 读值:

1. 洗板,在 HRP 酶标孵育后,用 PBST/TBST washing buffer(含表面活性剂)洗板 3 次;

2. 显色,加入 100μL 底物,在 20~37℃孵育一定时间,显色为蓝色;

3. 终止:加入 100μL TMB 终止液 450,显色变黄色;

4. 读数:建议在 30 分钟内读取波长 450 处的吸光值;

650nm 读值:

1. 洗板,HRP 酶标孵育后,用 PBST/TBST washing buffer(含表面活性剂)洗板 3 次;

2. 显色,加入 100μL 底物,在 20~37℃孵育一定时间,显色为蓝色;

3. 终止:加入 100μL TMB 终止液 650,显色为蓝色;

4. 读数:建议在 30 分钟内读取波长 650 处的吸光值;

动力学 650nm 读值:

1. 洗板,HRP 酶标孵育后,用 PBST/TBST washing buffer(含表面活性剂)洗板 3 次;

2. 显色,加入 100μL 底物,在 20~37℃孵育;

3. 读数:按照既定的频率(如每隔 1 分钟)读取波长 650nm 处的吸光值;

Aladdin's Highly Sensitive TMB Chromogen Solution for ELISA utilizes the single TMB chromogen solution to detect horseradish peroxidase (HRP) activity with low background production. This product can also be used to determine the content of HRP in samples such as blood or hemoglobin.TMB, also known as 3,3',5,5'-Tetramethylbenzidine, is a conventional substrate of HRP. Under the catalysis of HRP or other appropriate peroxidases, TMB produces a soluble blue reaction product which absorbs at 370nm or in a range of 620nm to 650nm [1,2]. The reaction can be terminated using an appropriate stop solution, such as Stop Solution for TMB Substrate (450nm, Sulfuric acid free) , Stop Solution for TMB Substrate (650nm, non-corrosiveness) , or 2M H2SO4. When using the Stop Solution for TMB Substrate (450nm, Sulfuric acid free) , a soluble yellow reaction product is produced and its absorbance can be measured at 450nm. However, when Stop Solution for TMB Substrate (650nm, non-corrosiveness) is used, a soluble blue reaction product with an absorbance at 620-650nm will be produced.This chromogen solution is a ready-to-use, single-component solution that does not require the addition of hydrogen peroxide or other reagents, simplifying the operation and ensuring more stable and reliable assay results.This chromogen solution is an aqueous solution, without any organic solvents such as alcohol, DMF, or DMSO, making it safe and non-toxic to use.This product is approximately 2 times more sensitive than Aladdin's TMB Chromogen Solution for ELISA , and enables a faster reaction rate as well. However, the Supersensitive TMB Chromogen Solution for ELISA has better performance than this product in terms of both sensitivity and reaction rate. Please refer to Figure 1 and Figure 2 for the comparison of these three products.Figure 1. Reaction kinetics of Aladdin's Highly Sensitive TMB Chromogen Solution for ELISA , Supersensitive TMB Chromogen Solution for ELISA , and TMB Chromogen Solution for ELISA . In 96-well plates, mix 20µl of diluted HRP-labeled Streptavidin in PBS, and 100µl of P0206, P0208, or P0209 in respective wells. The reactions were incubated at 25℃ and the absorbance was measured at 650nm every 2 minutes. As shown in the figure, the reaction rate of P0206 is approximately 2 times that of P0209, but lower than P0208. This figure is for reference only, which may vary due to different experimental conditions.Figure 2. The performance of Aladdin's Highly Sensitive TMB Chromogen Solution for ELISA , Supersensitive TMB Chromogen Solution for ELISA, and TMB Chromogen Solution for ELISA in detecting the HRP-labeled Streptavidin . HRP-labeled Streptavidin was gradient-diluted with PBS. In 96-well plates, mix 20µl of diluted HRP-labeled Streptavidin and 100µl of P0206, P0208, or P0209 in respective wells, resulting in concentrations of HRP-labeled Streptavidin as shown in the figure. After incubating reactions at room temperature in the dark for 5 minutes, add 100µl of Stop Solution for TMB Substrate (450nm, sulfate-free) per well to stop the reactions, and absorbance at 450nm was measured. A, Standard curve with the concentration of HRP-labeled Streptavidin on the x-axis and A450 on the y-axis, and a four-parameter logistic regression (4PL) commonly used in ELISA was applied. B, Absorbance of reactions with low concentrations of HRP-labeled Streptavidin and a linear regression was performed. As shown in the figure, the signal value of P0206 reactions is approximately 2 times that of P0209 reactions with appropriate amounts of HRP. This figure is for reference only, which may vary due to different experimental conditions.This product is most commonly used for ELISA, but it can also be used to examine the peroxidase content in samples such as blood or hemoglobin.Typically, use 0.1mL of chromogen solution per well for ELISA. Thus per 100mL of this product is sufficient for approximately 1000 assays.


Precautions:

Storage at -20℃is not recommended for this product. The assay signal may decrease by approximately 10% after three freeze-thaw cycles.This product should be protected from direct light exposure. Avoid direct contact with heat sources, metals, or oxidizing agents.Do not use this product directly from the bottle. It is recommended to take out the required amount of solution from the bottle for each experiment and the unused residuals should not be poured back into the bottle.This product is a colorless to slightly yellow transparent solution. It should be discarded when becoming turbid or changing to a darker blue color.TMB can be irritating to the human body. Please avoid direct contact or inhalation.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear a lab coat and disposable gloves during the operation.


Instructions for Use:

1. For ELISA:a. Prior to use, equilibrate the TMB Chromogen Solution to room temperature.b. Following the instructions of the ELISA kit, after incubation with the HRP-labeled antibody, wash the wells 3-5 times with an appropriate wash buffer for 3-5 minutes each time. c. Remove the wash buffer and add 100μl of the TMB Chromogen Solution.d. Incubate at room temperature in the dark for 3-30 minutes, or until the desired color intensity is achieved. The chromogenic reaction is rapid and the reaction time can be shortened if necessary.e. Measure the absorbance at 370nm or 620-650nm. Alternatively, add 100μl of the Stop Solution for TMB Substrate (450nm, Sulfuric acid free) , Stop Solution for TMB Substrate (650nm, non-corrosiveness) , or 2M H2SO4 to terminate the reactions before absorbance measurement at the corresponding wavelength.2. For other assays in 96-well plates, such as detecting endogenous peroxidase in tissue or cell samples:a. Add 10-20μl of sample into each well of 96-well plates.b. Add 100μl of the TMB Chromogen Solution per well.c. Incubate at room temperature in the dark for 3-30 minutes or longer until the desired color intensity is achieved.d. Measure the absorbance at 370nm or 620-650nm. Alternatively, add 100μl of the Stop Solution for TMB Substrate (450nm, Sulfuric acid free) , Stop Solution for TMB Substrate (650nm, non-corrosiveness) , or 2M H2SO4 to terminate the reactions before absorbance measurement at the corresponding wavelength.FAQ:1. The background is too dark.a. Use an appropriate blocking buffer or serum (10%) from the same source as the primary antibody for blocking. b. Use secondary antibodies that have been appropriately adsorbed to reduce non-specific binding of secondary antibodies.c. Shorten the reaction time or reduce the concentration of secondary antibodies. d. Use an appropriate wash buffer or extend the washing time.2. No staining or weak staining.a. Increase the concentration of primary or secondary antibody. To test the effectiveness of the secondary antibody, check if the diluted secondary antibody can react with the TMB Chromogen Solution properly.b. Use a more sensitive amplification assay, such as a biotin assay.c. Extend the reaction time if necessary.d. Use a more sensitive TMB chromogen solution, such as 's Supersensitive TMB Chromogen Solution for ELISA , to achieve better assay results. e. Use a more effective primary antibody or ELISA kit.References:1. Josephy PD, Eling T, Mason RP. J Biol Chem. 1982. 257(7):3669–3675.2. Liem HH, Cardenas F, Tavassoli M, Poh-Fitzpatrick MB, Muller-Eberhard U. Anal Biochem. 1979. 98(2):388–393.


规格

产品名称
高灵敏TMB显色液(ELISA HRP显色用)
分子类型
生物试剂/缓冲液
储存与运输
物理形态
液体
储存条件
2-8°C储存,避光
运输条件
低温运输

技术文档

📋 安全数据表 (SDS)

全面的危险、操作、储存及法规合规文件。

下载 SDS →

✅ 分析证书 (COA)

批次质量数据。输入批号以获取对应 COA。

查询 COA →

📊 产品数据表

产品规格和应用的快速参考摘要。

查看数据表 →

🔬 规格说明书

该级别的完整质量属性和验收标准。

查看规格说明 →

高级数据

质检证书(CoA,COO,BSE/TSE 和分析图谱)
C of A & Other Certificates(BSE/TSE, COO):
输入批号以搜索分析图谱:

通过匹配包装上的批号来查找并下载产品的 COA,每批产品都进行了严格的验证,您可放心使用!

找到2个结果

批号(Lot Number) 证书类型 货号
J2408223 分析证书 H743375
J2408225 分析证书 H743375
技术文档和文章
溶液计算器