FOOD RESEARCH INTERNATIONAL
·
2022
·
IF 7.425
Chao Qi,Yueying Jin,Shengyu Cheng,Lei Di,Xin Wang,Minghui Zhang,Lingli Zhang,Xi-Ling Li,Yu Han,Qingkun Ma,Jun Zhe Min
α-dicarbonyl compounds (α-DCs) serve as potential biomarkers for oxidative stress-related diseases but are difficult to detect. To study the metabolism of carbonyl compounds , we developed a new mass spectrometry probe, 3-benzyl-2-oxo-4λ 3 -thiazolidine-4-carbohydrazide (BOTC), containing hydrazyl groups for the targeted detection of carbonyl functional groups. In a novel approach, we used BOTC pre-column derivatization with ultrahigh performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) to simultaneously detect four kinds of α-DCs in red wine as well as in urine after drinking. The α-DCs were completely separated (R 2 ≥ 0.9995), detection was sensitive (detection limit was 12.5–50 fmol), consistent (intraday and interday precision was 0.1–5.7 %), and efficient (average recoveries were 103.3–110.2 %). The method was applied to the analysis of α-DCs in different wines and the dynamic monitoring of transit and excretion in vivo after drinking. Our novel method provides a new strategy for the detection of α-dicarbonyl compounds in red wine and dicarbonyl compounds produced in oxidative stress-related diseases.
研究领域:
分析化学
·
医学
·
食品科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
FOOD CHEMISTRY
·
2024
·
IF 8.5
Jiaxi Wen,Kehan Zhang,Yujun Liu,Zhifeng Du,Chaomei Xiong,Hongliang Jiang
Estrogens and their analogues can cause harm to human health through the food chain. Ten estrogens in different milk samples were directly extracted by amphiphilic divinylbenzene/ N -vinyl-2-pyrrolidone (DVB/NVP)-Fe 3 O 4 @SiO 2 -based magnetic solid-phase extraction (MSPE) followed by pre-column derivatization and ultra-high performance liquid chromatography tandem mass-spectrometry (UHPLC-MS/MS) detection. Under the optimal conditions, the limits of detection for ten analytes were in the range of 0.05–0.38 ng mL −1 in whole liquid milk matrix and 0.04–3.00 ng g −1 in milk powder matrix. The intra-/inter-day accuracy ranged in 83.4–113.8%, with RSDs in 2.5–15.0%. A total of 15 brands of liquid milk and milk powder samples were analyzed, and only estradiol was detected in three brands of boxed liquid milk within safe range. The proposed sample pretreatment eliminated the common protein precipitation process, improved the sample throughput, and has the potential for routine testing of estrogens and their analogues in market-sale milk samples.
研究领域:
分析化学
·
食品安全
·
环境科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF HAZARDOUS MATERIALS
·
2020
·
IF 9.038
Gege Wu,Jiping Ma,Shasha Wang,Huining Chai,Liang Guo,Jinhua Li,Abbas Ostovan,Yafeng Guan,Lingxin Chen
A novel kind of cationic metal-organic framework(MOF) based mixed-matrix membrane(MMM) namely cationic MOF-MMM was firstly designed and used for simultaneous dispersive membrane extraction(DME) of six phenoxy carboxylic acid(PCA) herbicides from water samples followed by determination using ultrahigh-performance liquid chromatography tandem mass spectrometry. The cationic MOF-MMM was synthesized by soaking the zirconium-based MOFs in a polyvinylidene fluoride(PVDF) solution and further functionalization with quaternary amine groups, viz., UiO-66-NMe 3 + MMM. The well-prepared UiO-66-NMe 3 + MMM was characterized by FT-IR, SEM, XRD, XPS, NMR and etc. Several main variables influencing the MMM based DME efficiency were investigated and optimized in detail, such as dosage ratio of MOF/PVDF, solution pH, extraction time, coexistent anions and ionic strength. Electrostatic interactions dominated adsorption mechanism between anionic PCAs and cationic UiO-66-NMe 3 + MMM, along with π π conjugation and cation-π bonding, leading to better adsorption performance. Low limits of detection in the range of 0.03–0.59 ng/L and satisfactory recoveries within 80.06–117.40 % for all the PCAs are a reliable witness to demonstrate supreme sensitivity and the applicability of the developed method. By relying on the obtained results, the present work implied cationic MOF-MMM based DME can be a versatile and worthy utility for extraction of pollutants from different water samples with high throughput.
研究领域:
分析化学
·
环境科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ACS Food Science & Technology
·
2025
·
IF 2.8
Zhimei Fan,Danni Zhang,Xueqian Guo,Yiwen Zhu,Panpan Chen,Chenxi Qiu,Ninglong Zhang,Jian Zhang,Liqiong Niu,Xichang Wang,Yuan Liu
Clanis Bilineata larva (CBL) is a unique Chinese insect delicacy in Jiangsu Province, which is known for its umami taste and high protein nutrition. To develop its desired flavor, the quantitative descriptive analysis (QDA) combined with high throughput instruments were applied to analyze the sensory attributes and compounds of raw, boiled and roasted CBLs. Through QDA, cooked CBLs showed higher meaty odor intensities than Raw CBL significantly (p < 0.05). Compared with boiled CBL, the roasting process could generate the roasted meaty/beany odors and umami/savory taste while reducing the negative effects of grassy/boiled vegetable/earthy odors and bitter taste. Pearson correlation analyses results showed that meaty odor was highly correlated with compounds produced by fatty acid degradation such as hexanal and 1-octen-3-ol. Meanwhile, histidine was highly correlated with bitter and adenosine monophosphate was highly correlated with umami. The taste and odor of cooked CBLs are mainly formed from the lipid degradation, protein degradation and nucleotide degradation. This study provides insights to use a proper cooking process to develop consumer-friendly CBL products.
✓ 已验证
产品关联
DOI
高影响因子
MICROCHEMICAL JOURNAL
·
2026
·
IF 5.2
Yun Wu,Shuting Yang,Yanqun Yang,Lijuan Long,Shuixin Ding,Chunyan Su,Linchun Bao,Qianchun Zhang
A novel magnetic nanocomposite (FPB@PEI@PDA@Fe 3 O 4 ) was synthesized for selective enrichment of HPAHs. • The MSPE-UHPLC-MS/MS method was developed to quantify nine trace HPAHs in urine and serum. • The Langmuir model governs adsorption, involving π–π, hydrogen bonding, electrostatic, and boronate affinity interactions. Hydroxylated polycyclic aromatic hydrocarbons (HPAHs) are bioaccumulative and environmentally persistent contaminants, recognized for their significant carcinogenic potential. However, accurate analysis remains challenging due to the inherent complexity of biological matrices (e.g., high protein content and numerous interfering compounds) and the ultra-trace concentrations (ng/L or pg/L levels) at which HPAHs typically occur. The efficient isolation of these analytes therefore requires a specially designed sorbent capable of strong interactions with HPAHs. To address this challenge, we designed and synthesized a novel magnetic adsorbent, 4-carboxy-3-fluorophenylboronic acid-functionalized polyethylenimine-coated polydopamine@Fe 3 O 4 (FPB@PEI@PDA@Fe 3 O 4 ), for use in magnetic solid-phase extraction (MSPE). Leveraging the properties of this novel material, an efficient MSPE-ultra-high pressure liquid chromatography-mass spectrometry method was developed to isolate and quantify nine HPAHs in urine and serum, with high sensitivity and selectivity, a wide linear range (0.0050–10 μg/L), and low detection limits (1.5–40 ng/L). To validate its applicability for human biomonitoring, urine and serum samples were analyzed, and four HPAHs, 1-naphthol, 9-phenanthrol, 1-phenanthrol, and 4-phenanthrol, were identified and quantified. The method exhibited satisfactory accuracy and precision, with recoveries of 80.3%–114% and relative standard deviations of 2.4%–13%. These results enable further understanding of the distribution and potential risks of HPAHs, and the method facilitates more accurate human health assessment and environmental monitoring. Download: Download high-res image (135KB) Download: Download full-size image
✓ 已验证
DOI
高影响因子
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
·
2018
·
IF 2.831
Zhuoling Zheng,Shuyu Zhang,Wudi Ma,Lingyi Zhang,Ling Huang,Wenqi Huang,Min Huang,Zhongxing Wang,Jiali Li
The combination of dexmedetomidine (DEX) and propofol (PPF) is extensively used in the field of anaesthesiology. This study aimed to develop and validate a rapid, simple and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC–MS/MS) method for the determination of DEX in human plasma. The method was applied to evaluate the effect of DEX concentration on the target-controlled infusion (TCI) concentration of PPF. Analytes were separated on a Waters XTERRA ® MS C18 column with a mobile phase of acetonitrile-methanol-water containing 0.1% formic acid and 5 mM ammonium acetate (70:10:20, v/v/v ) at a flow-rate of 0.3 mL/min. Mass spectrometry was performed in the positive selection reaction monitoring mode. The 201.12 → 95.12 and 515.29 → 275.68 mass transitions of DEX and IS (telmisartan), respectively, were monitored. The calibration curve of DEX was linear over the concentrations of 0.1–10 ng/mL. The intra-batch and inter-batch precisions of quality control samples were less than 10.05% and had accuracies of less than 6.25%. The newly developed method was successfully applied to quantify the DEX concentrations of plasma samples from 34 patients who were co-medicated with DEX prior to receiving anaesthesia by PPF. Results showed that comedication with DEX could reduce the requirements of PPF. Specifically, it was firstly found that the concentration of DEX is negatively correlated with the TCI concentration of PPF at the time of loss of consciousness.
研究领域:
药理学
·
麻醉学
·
临床医学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
EUROPEAN FOOD RESEARCH AND TECHNOLOGY
·
2024
·
IF 3
Kong Xinxin,Zhang Lingli,Cai Ling,Cheng Shengyu,Li Xi-Ling,Jin Toufeng,Min Jun Zhe
Selenium (Se) is a vital trace element for mammals, but excessive intake can lead to selenium poisoning. To manage Se intake properly, this study developed a novel method using ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS). This technique allows the simultaneous detection of three selenoamino acids in supplements. The three selenoamino acids were fully separated within 3 min. The method demonstrated excellent linearity (R 2 ≥ 0.9993), high sensitivity (detection limits were 2.49–2.92 fmol), and good precision (intraday and interday precision ranged from 2.87 to 13.54%). This study applied this method to analyze the content of selenoamino acids in organic selenium supplements from various sources and to dynamically monitor their absorption and excretion in the body after consumption. The novel approach offers a new strategy for the quality control of selenium-containing supplements and for studying selenium absorption and metabolism. Graphical abstract
研究领域:
分析化学
·
营养学
·
毒理学
✓ 已验证
产品关联
DOI
高影响因子
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
·
2023
·
IF 3.4
Jieyu Zhang,Yan Chen,Wenxiang Fan,Linnan Li,Yueming Ma,Zhengtao Wang,Rong Shi,Li Yang
The combined efficacy in lowering serum lipid levels and increasing kidney protection of Plantago asiatica L. seed (Plantago) and Coptis chinensis Franch. rhizoma (Coptis) is far better than the effects of either herb alone. This finding suggests that there must be some degree of herb-herb interactions (HHI) affect potency. Here, we chose geniposidic acid (GPA), acteoside (ACT), and plantagoamidinic acid A (PLA) as active components in Plantago, and berberine (BBR) as the active component in Coptis, and, using transporter gene-transfected Madin-Darby canine kidney (MDCK) cells in combination with specific substrates and inhibitors, investigated Plantago- Coptis HHIs. We also established a UPLC-MS/MS analytical method to determine substrate content. Results showed that PLA in Plantago was a substrate of rOCT1/2 and rMATE1, and had inhibitory effects on rOCT2 and rMATE1. We also found that ACT is a substrate of rMATE1, but GPA was not a substrate of any transporter that we investigated. When BBR was used as the substrate, the inhibition rate of 10 μM PLA was 53.6% on rOCT2 and 31.5% on rMATE1. The inhibition rates of 30 μM ACT and 30 μM GPA on rMATE1 were 47.0% and 31.0%, respectively. Thus, our findings suggest that GPA, ACT, PLA, and BBR have competitive interactions that are driven by the rOCT2 and rMATE1 transporters. These interactions affect the transport and excretion of compounds and result in efficacy changes after co-administration.
研究领域:
药理学
·
药学
·
中药学
·
分析化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
BIOMEDICAL CHROMATOGRAPHY
·
2020
·Vol. 34
·期 8
·e4845
·
IF 1.728
Yubin Ji,Hongjun Luo,Hui Li,Zhexuan Lin,Wenhong Luo
An ultra-high performance liquid chromatography tandem mass spectrometry method was developed for determination of homocysteine (HCY) in human plasma. The HCY was derivatized with 2-chloro-1-methylquinolinium tetrafluoroborate and isolated using solid-phase extraction. Derivatization, isolation and detection procedures were optimized. Satisfactory linearity was obtained with determination coefficients ( r 2 ) >0.999. The intra- and inter-day precisions were in the interval of 1.2–5.1% and accuracy was within ±7%. Mean recoveries were close to 100%. The limit of detection and the limit of quantification were 0.46 and 1.38 μmol/L, respectively. The method was then applied to investigate the relationship between plasma HCY and whole blood 5-methyltetrahydrofolate levels in healthy volunteers. The results revealed that the plasma level of HCY was significantly negatively correlated to whole blood 5-methyltetrahydrofolate in volunteers.
研究领域:
医学检验
·
营养学
✓ 已验证
DOI
高影响因子
MOLECULES
·
2020
·Vol. 25
·期 4
·897
·
IF 3.267
Qian-Chun Zhang,Guang-Ping Xia,Jun-Yi Liang,Xiao-Lan Zhang,Li Jiang,Yu-Guo Zheng,Xing-Yi Wang
In this study, a novel monolithic capillary column based on a NH2-MIL-53(Al) metal–organic framework (MOF) incorporated in poly (3-acrylamidophenylboronic acid/methacrylic acid-co-ethylene glycol dimethacrylate) (poly (AAPBA/MAA-co-EGDMA)) was prepared using an in situ polymerization method. The characteristics of the MOF-polymer monolithic column were investigated by scanning electron microscopy, Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, X-ray diffractometry, Brunauer-Emmett-Teller analysis, and thermogravimetric analysis. The prepared MOF-polymer monolithic column showed good permeability, high extraction efficiency, chemical stability, and good reproducibility. The MOF-polymer monolithic column was used for in-tube solid-phase microextraction (SPME) to efficiently adsorb trace sulfonamides from food samples. A novel method combining MOF-polymer-monolithic-column-based SPME with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was successfully developed. The linear range was from 0.015 to 25.0 µg/L, with low limits of detection of 1.3–4.7 ng/L and relative standard deviations (RSDs) of < 6.1%. Eight trace sulfonamides in fish and chicken samples were determined, with recoveries of the eight analytes ranging from 85.7% to 113% and acceptable RSDs of < 7.3%. These results demonstrate that the novel MOF-polymer-monolithic-column-based SPME coupled with UHPLC-MS/MS is a highly sensitive, practical, and convenient method for monitoring trace sulfonamides in food samples previously extracted with an adequate solvent.Keywords:monolithic capillary column;metal-organic framework;sulfonamides;solid-phase microextraction;ultra-high performance liquid chromatography-tandem mass spectrometry
研究领域:
分析化学
·
食品科学
·
材料科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF SEPARATION SCIENCE
·
2021
·Vol. 45
·期 4
·919-928
·
IF 3.645
Qianchun Zhang,Xiaolan Zhang,Bingnian Yang,Shan Liu,Ming Wen,Linchun Bao,Li Jiang
Hydroxyl polycyclic aromatic hydrocarbons are considered active mutagenic and carcinogenic substances and are found in extremely low levels (ng/g) in biological samples. As a result, their determination in urine and blood samples is challenging, and a sensitive and effective method for the analysis of trace hydroxyl polycyclic aromatic hydrocarbons in complex biological matrices is required. In this work, a novel macroporous in-tube solid-phase microextraction monolith was prepared via a thiol-yne click reaction, and a highly efficient analytical method based on in-tube solid-phase microextraction coupled with UHPLC-MS/MS was developed to determine hydroxyl polycyclic aromatic hydrocarbons with low detection limits of 0.137–11.0 ng/L in complex biological samples. Four hydroxyl polycyclic aromatic hydrocarbons, namely, 2-hydroxyanthraquinone, 1-hydroxypyrene, 1,8-dihydroxyanthraquinone, and 6-hydroxychrysene, were determined in the urine samples of smokers, non-smokers, and whole blood samples of mice. Satisfactory recoveries were achieved in the range of 83.1–113% with relative standard deviations of 3.2–9.7%. It was found that implementation of the macroporous monolith gave a highly efficient approach for enriching trace hydroxyl polycyclic aromatic hydrocarbons in biological samples.
研究领域:
分析化学
·
环境科学
·
毒理学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYTICA CHIMICA ACTA
·
2022
·
IF 6.911
Yurui Li,Xiuli Xu,Hongbo Guo,Yu Bian,Jie Li,Feng Zhang
A novel magnetic graphene oxide−based covalent organic frameworks, was prepared initially by grafting two monomers , tris(4−aminophenyl)amine and 2, 4, 6−triformylphloroglucinol onto Fe 3 O 4 nanoparticles attached to graphene oxide scaffolds. It exhibited a regular core−shell spherical structure, super paramagnetism , and desirable adsorbability for five triazine herbicides, and was thus served as adsorbent of magnetic solid−phase extraction. An analytical strategy coupled magnetic solid phase extraction with UHPLC−MS/MS was then developed for the determination of triazine herbicide residues in fruit and vegetable samples. The validation results revealed good linearity in the concentration range of 0.01–200 μg L −1 (r ≥ 0.9925). LODs of the method were in the range of 0.01–0.05 μg kg −1 , LOQs in the range of 0.05–0.2 μg kg −1 and recoveries ranged from 72.3 to 112.8%. The results showed that the prepared adsorbent provided desirable adsorption capacity of triazine herbicides, demonstrating great potential in the detection of trace triazine herbicides in complex food matrices.
研究领域:
分析化学
·
环境科学
·
材料科学
·
食品科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子