文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,438+ SCI 论文 与阿拉丁产品引用相关
2,295,919.25 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第205至212个,产品总数212个

设置提升方向
hydroquinone
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS · 2025 · IF 5.4

In-situ polymerization strategy for conductive polymer poly(3,4-ethylenedioxythiophene) on bimetallic MOF to enhance electrochemical detection of toxic hydroquinone in industrial wastewater and tap water

Ming Sun,Li Zhang,Shaobin Li,Fengbo Li,Yu Han,Tingting Yu,Zixu Lin

Hydroquinone is an organic pollutant that poses significant risks to the environment and human health, rapid and effective monitoring is essential. In this work, a simple and efficient electrochemical sensor based on poly(3,4-ethylenedioxythiophene) coated onto a bimetallic metal-organic framework (ZnCo-ZIF-67) was constructed by using an in-situ polymerization strategy at room temperature. The electrochemical sensor demonstrates excellent performance with a broad linear range (2–212 μM, 212–662 μM), high sensitivity (0.51 μA·μM −1 ·cm −2 ), and a low limit of detection of 0.468 μM. The sensor exhibits excellent selectivity, repeatability, reproducibility, and anti-interference performance. Moreover, it effectively detects hydroquinone in both tap water and industrial wastewater, achieving recoveries ranging from 97.30 % to 102.83 %, with relative standard deviations (RSD) below 3.80 %. These results highlight the significant potential of the sensor for monitoring hydroquinone in environmental water systems.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2025 · IF 9.8

Controllable selenization strategy for in-situ construction of V2CTx MXene-based multiphase electrode materials for simultaneous detection of hydroquinone and catechol in drinking water and beverages

Yu Han,Li Zhang,Shaobin Li,Fengbo Li,Jianjiao Xin,Xue Wang,Minjie Liang

Hydroquinone (HQ) and catechol (CC) are toxic isomers with similar structures that often coexist, leading to interference during detection. In this study, we employed a controllable selenization strategy to construct V 2 CT x MXene-based multiphase electrode materials (VSe 2 @V 2 O 3 @V 2 CT x MXene) for the simultaneous detection of HQ and CC. Electrochemical tests revealed VSe 2 @V 2 O 3 @V 2 CT x MXene modified electrode exhibited low electrochemical impedance, a large active surface area, and excellent electrocatalytic performance. The sensor demonstrated linear detection ranges for HQ and CC from 0.5 to 600 μM, with limits of detection 0.144 μM and 0.131 μM, respectively. Additionally, it exhibited excellent repeatability, reproducibility, selectivity, and stability. The practical applicability of the sensor was confirmed through testing in drinking water and beverages, showing satisfactory recovery rates. This work expands the application of V 2 CT x MXene in the field of electrochemical sensing and offers new insights for food safety monitoring.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL LETTERS · 2025 · IF 1.8

Electrochemical Detection of Hydroquinone (HQ) and Catechol (CC) in Environmental Samples Using a Pretreated Glassy Carbon Electrode (p-GCE) Modified with a Vertically-Ordered Mesoporous Silica Film (VMSF)

Qinqin Sun,Jing Wang,Zhengzheng Liu,Lujie Wang,Jun Zhang,Biaowei Liu,Liqiong Huang,Fei Yan,Jinsong Liu

Convenient and sensitive detection of hydroquinone (HQ) and catechol (CC) in environmental samples holds great importance for monitoring. Herein, a vertically-ordered mesoporous silica film (VMSF) supported on the electrochemically pretreated glassy carbon electrode (p-GCE) is prepared by a simple and environmentally friendly electrochemical method and employed to construct a sensitive and anti-fouling sensing interface for quantitative detection of HQ and CC. In virtue of a simple electrochemical polarization, the p-GCE shows enhanced electroactive area and promoted electrochemical activity, as well as oxygen-containing groups, rendering a sensitive electrode substrate with improved analytical performance and the functional interface for stable growth of VMSF. The obtained VMSF/p-GCE has superior electroanalytical capacity toward HQ and CC due to the synergistic effect of hydrogen bonding of VMSF and the sensitive p-GCE electrode substrate. The developed VMSF/p-GCE sensor enables the determination of HQ and CC with a wide linear range (1 ∼ 120 μM), high sensitivity (0.368 μA/μM for HQ and 0.404 μA/μM) and low limit of detection (268 nM for HQ and 80 nM for CC). Furthermore, the capacity of the prepared VMSF/p-GCE in the analysis of HQ and CC in environmental water samples and soil leaching solutions has been studied, showing acceptable results and therefore offering a simple and low-cost way for environmental analysis.

研究领域: 环境分析化学 · 电分析化学 · 传感器与生物传感器 · 环境监测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2022 · IF 9.965

In situ growth of ZIF-67-derived nickel-cobalt-manganese hydroxides on 2D V2CTx MXene for dual-functional orientation as high-performance asymmetric supercapacitor and electrochemical hydroquinone sensor

Tingting Yu,Shaobin Li,Li Zhang,Fengbo Li,Jianxin Wang,Hong Pan,Deqing Zhang

Designing dual-functional electrode materials for supercapacitors and pollutant sensors has attracted great interest from researchers for urgent demand in green energy and the environment. In this work, a novel electrode material V 2 CT x @NiCoMn-OH was successfully constructed for dual-functional orientation via a two-step synthesis strategy, in which the NiCoMn-OH with a three-dimensional (3D) hollow structure was fabricated by employing ZIF-67 as a template and simple anion exchange and composited with the two-dimensional (2D) layered V 2 CT x MXene. The intercalation of NiCoMn-OH can effectively limit the self-accumulation of V 2 CT x MXene nanosheets and build a 3D cross-linked hollow structure, thereby broadening the ion transport channel, exposing more active sites of V 2 CT x @NiCoMn-OH, and simultaneously improving the conductivity of NiCoMn-OH. Benefiting from the unique 3D cross-linked hollow structure, the optimized V 2 CT x @NiCoMn-OH-20 electrode material exhibits an excellent specific capacitance of 827.45 C g −1 at 1 A g −1 . Furthermore, the electrode material has excellent capacitance retention of 88.44% after 10,000 cycles. Moreover, the V 2 CT x @NiCoMn-OH-20//AC ASC device displays a high energy density of 88.35 Wh kg −1 as well as high power density of 7500 W kg −1 during operation. Additionally, the V 2 CT x @NiCoMn-OH-20 exhibited excellent electrocatalytic performance in the detection of hydroquinone, including the low detection limit of 0.559 μM (S/N = 3) and the wide linear range of 2–1050 μM. Therefore, the prepared V 2 CT x @NiCoMn-OH-20 has great potential applications in the fields of supercapacitors and hydroquinone sensors.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2017 ·Vol. 184 ·期 9 ·3591-3601 · IF 4.58

Simultaneous voltammetric determination of hydroquinone and catechol by using a glassy carbon electrode modified with carboxy-functionalized carbon nanotubes in a chitosan matrix and decorated with gold nanoparticles

Shen Yu,Rao Dejiang,Sheng Qinglin,Zheng Jianbin

The authors describe a method to anchor gold nanoparticles (AuNPs) on carboxy-functionalized multi-walled carbon nanotubes (c-MWCNTs) utilizing chitosan as dispersing and protective agent. A sensor for the simultaneous determination of hydroquinone and catechol was then fabricated by placing this nanocomposite on a glassy carbon electrode (GCE). The morphology and composition of the nanocomposites were characterized by scanning electron microscopy, transmission electron microscopy, energy-dispersive X-ray spectroscopy and X-ray powder diffraction. The electrochemical behavior of the modified GCE was studied by electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry. The modified GCE exhibits good electrooxidative activity towards hydroquinone and catechol and therefore was used for simultaneous determination of both, with typical voltages of 30 and 130 mV (vs. SCE). A linear reponse is found for the 0.5 μM to 1.5 mM hydroquinone concentration range, and for the 5.0 μM to 0.9 mM catechol concentration range. The respective lower detection limits are 0.17 and 0.89 μM (at an S/N ratio of 3). The sensitivity is 644.44 μA mM −1  cm −2 for hydroquinone and 770.98 μA mM −1  cm −2 for catechol. An electrochemical sensor for the simultaneous determination of hydroquinone and catechol was fabricated by modifying the c-MWCNTs/CTS/Au nanocomposites on a glassy carbon electrode (GCE).

CAS / MDL: 308068-56-6
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2019 ·Vol. 186 ·期 3 ·1-8 · IF 5.479

Voltammetric simultaneous determination of catechol and hydroquinone using a glassy carbon electrode modified with a ternary hybrid material composed of reduced graphene oxide, magnetite nanoparticles and gold nanoparticles

Kong Fen-Ying,Li Rong-Fang,Yao Lei,Wang Zhong-Xia,Li Heng-Ye,Lv Wei-Xin,Wang Wei

An electrochemical sensor is described for the simultaneous determination of the pollutants catechol (CC) and hydroquinone (HQ). A glassy carbon electrode (GCE) was modified with reduced graphene oxide, Fe 3 O 4 and gold nanoparticles and then showed a pair of well-defined voltammetric peaks for CC and HQ. Its oxidation peak potentials (located at 0.21 and 0.10 V vs. Ag/AgCl) are well separated, and this makes it suitable for simultaneous determination of the two isomers. Under optimal conditions, the oxidation peak currents of CC and HQ increase linearly in the 0.05–550 μM and 0.1–500 μM concentration ranges, even in the presence of 0.1 mM of the respective other isomer. The detection limits are 0.02 and 0.17 μM (at S/ N  = 3), respectively. The modified GCE exhibits good selectivity and recovery when applied for the analysis of spiked wastewater. Ternary hybrid nanomaterials of rGO-Fe 3 O 4 -Au was developed for simultaneous electrochemical determination of catechol (CC) and hydroquinone (HQ).

CAS / MDL: 7782-42-5
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHEMICAL AND ENGINEERING DATA · 2020 · IF 2.369

Synergistic Extraction of Hydroquinone from an Aqueous Solution with a Solvent Mixture of Diisopropyl Ether and n-Pentanol at T = 298.15 K and P = 101.3 kPa: Liquid–Liquid Equilibria and Data Correlation

Miyangzi Suo,Bokun Chen,Yu Qian,Siyu Yang

The synergistic effect for a solvent mixture of diisopropyl ether and n-Pentanol to extract hydroquinone from aqueous solution was investigated. Liquid–liquid equilibrium data of the quaternary (n-Pentanol + diisopropyl ether + water + hydroquinone) system were measured at T = 298.15 K and P = 101.3 kPa, using various compositions of solvent mixture. It can be seen from the slope of the tie lines that with the increase of distribution coefficients of hydroquinone, the size of the immiscible solution region decreased slightly. The extraction efficiency was evaluated by calculating the separation factor and distribution coefficient. Using the universal quasichemical (UNIQUAC) and nonrandom two-liquid (NRTL) models to correlate with experimental data, the corresponding binary interaction parameters were obtained. The RMSD values of UNIQUAC and NRTL models showed that the calculated results were in good agreement with the liquid–liquid equilibrium data.

CAS / MDL: 71-41-0
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2020 ·Vol. 187 ·期 6 ·1-8 · IF 6.232

A double carbon dot system composed of N, Cl-doped carbon dots and N, Cu-doped carbon dots as peroxidase mimics and as fluorescent probes for the determination of hydroquinone by fluorescence

Wang Xiuli,Cheng Zhili,Zhou Yun,Tammina Sai Kumar,Yang Yaling

A fluorescence method is described for the determination of hydroquinone based on the double carbon dot system as peroxide mimic enzymes and fluorescent probes. Deep eutectic solvent (DES)–based fluorescent carbon dots (N/Cl-CDs) and copper-doped carbon dots (N/Cu-CDs) were prepared by the hydrothermal method. Both carbon dots were characterized with transmission electron microscopy (TEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), ultraviolet-visible (UV-Vis) spectroscopy, X-ray photoelectron spectrometry (XPS), Fourier transform infrared (FT-IR) spectroscopy, and fluorescence spectroscopy. N/Cl-CDs displayed intrinsic peroxidase-like activity and were able to catalyze the oxidation of hydroquinone (H 2 Q) to p-benzoquinone (BQ) along with an intermediate. The intermediate (BQ) did quench the N/Cu-CD photoluminescence (PL) at 450 nm using an excitation wavelength of 347 nm. Based on the results, a fluorescent platform is proposed for the determination of hydroquinone with a promising determination limit of 0.04 μM (linear range, 1.0–75 μM). The recoveries of spiked water samples were in the range 89.5–105.1%, with relative standard deviations (RSDs) of 1.5–2.9%. This method was applied to determination of H 2 Q in environmental water samples. A fluorescence method was established for the determination of hydroquinone based on the double carbon dot system as peroxide-mimic enzymes and fluorescent probes. Chlorine-doped carbon dots (N/Cl-CDs) derived from deep eutectic solvent (DES) displayed intrinsic peroxidase-like activity, and were able to catalyze the oxidation of hydroquinone (H2Q) to p-benzoquinone (BQ) along with an intermediate. The intermediate (BQ) did quench the N/Cu-CD photoluminescence (PL). This method was applied to H2Q in environmental water samples.

CAS / MDL: 56-40-6 123-31-9
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。