文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第421至432个,产品总数516个

设置提升方向
Hg2
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2025 · IF 4.6

Detection of Hg2+ in environmental water conditions by using a reusable SERS-based microfluidic chip with a high specificity and sensitivity

Yansheng Liu,Mengqi Wang,Guofu Wang,Xiaobo Jia,Jin Zhou,Hongqi Li,Haixin Chang,Zhaoxu Li

This work reported a surface-enhanced Raman spectroscopy (SERS)-based microfluidic chip that detects mercury ions (Hg 2+ ) in water with high sensitivity and good reproducibility. Silver nanoparticles (AgNPs) are easily fabricated on a Si substrate using a thin, thermally treated Ag film. Cy3 functionalized single-stranded DNA (Cy3-ssDNA) serves as the probe, which is immobilized on the AgNPs (Cy3-ssDNA/AgNPs), generating a SERS-based sensing surface. Due to the strong interaction between thymine (T) bases and Hg 2+ , in the presence of these ions, the ssDNA forms a T-Hg 2+ -T hairpin structure, which enhances the SERS signal. This method exhibits a limit of detection (LOD) of 1 × 10 −13  M. Furthermore, the proposed SERS chip demonstrates exceptional selectivity for mercury ions, as well as good reusability. The reusability of the SERS microfluidic chip was evaluated using the L-cysteine, which has a stronger affinity than T for Hg 2+ . By applying L-cysteine, the chip can be reused 10 times for the detection of Hg 2+ at concentrations as low as 1 × 10 −8  M. The method proposed in this study shows good sensitivity and holds good potential for application in the detection of Hg 2+ .

CAS / MDL: 1633-78-9
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2025 · IF 9.8

Fabrication of bifunctional gold nanoparticles for self-calibration UV–Vis/surface-enhanced Raman spectroscopy dual-mode analysis of Hg2+ in milk

Jinxin Chen,Zhihong Wang,Miao Ding,Ying Gu,Kun Ge,Xuejing Fan

Multimodal optical detection are good candidates in accuracy improvement in complex food detection, without sacrificing rapidity and sensitivity. Herein, bifunctional gold nanoparticles (AuNPs/4-MBA/Cy/T) based on step-by-step modification of 4-mercaptobenzoic acid, cysteamine, and thymine-1-acetic acid were fabricated for self-calibration ultraviolet-visible spectroscopy (UV–Vis)/surface-enhanced Raman spectroscopy (SERS) dual-mode detection of mercury ions (Hg 2+ ) in milks. The bifunctional UV–Vis and SERS analysis can be attributed to the localized surface plasmon resonance (LSPR) properties of AuNPs. The stable aggregation structure of AuNPs/4-MBA/Cy/T-Hg 2+ can be formed in the presence of Hg 2+ based on specific recognition of thymine, simultaneously decreasing UV–Vis signals and increasing SERS signals, also verified by theoretical simulations. Under the optimum conditions, the AuNPs/4-MBA/Cy/T was applied to establish UV–Vis/SERS dual-mode method for Hg 2+ detection in various milk samples with satisfied analytical performance including rapidity, sensitivity, specificity, accuracy, and repeatability. It offers a novel strategy in developing of self-calibration dual-mode detection for food contaminants analysis.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Arabian Journal of Chemistry · 2022 · IF 6.212

Dual recognition strategy for ultra-sensitive fluorescent detection of Hg2+ at femto-molar level based on aptamer functionalized sulfur quantum dots

Xiaobin Wang,Wei Guo,Xiaoling Wang,Qing Hua,Feiyan Tang,Xin Li,Feng Luan,Zhiyang Zhang,Chunyuan Tian,Xuming Zhuang,Lijun Zhao

In the present study, a dual recognition strategy for ultrasensitive detection of Hg 2+ was successfully developed for the first time based on aptamer functionalized sulfur quantum dots (Apt-SQDs). The developed Apt-SQDs not only retained the good fluorescence properties of quantum dots but also overcame the problem of poor selectivity of SQDs for heavy metal ions. This system used the dual recognition strategy, including the combination of S x 2− and Hg 2+ and T-Hg 2+ -T structures to excellently identify and capture Hg 2+ , and an ultrahigh sensitivity fluorescent aptasensor was fabricated. The fluorescent aptasensor had a good response to Hg 2+ at concentrations ranging of 10 −15 to 10 −7 M with an ultralow limit of detection of 0.3 fM, and the response to other metal ions was far less than that to Hg 2+ . It was successfully applied to detect Hg 2+ in nearby environmental water samples (tap water, lake water and river water) with a good recovery rate. Moreover, portable test papers that would be useful for Hg 2+ monitoring in environmental water were designed. The dual recognition strategy not only achieves ultrasensitive fluorescent detection of Hg 2+ but also provides a new insight into the further expansion of the application of SQDs.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Journal of Materials Chemistry B · 2019 ·Vol. 7 ·期 44 ·7033-7041 · IF 5.047

A dual-responsive fluorescent sensor for Hg2+ and thiols based on N-doped silicon quantum dots and its application in cell imaging

Sansan Shen,Bohui Huang,Xiaofeng Guo,Hong Wang

In this study, a simple and rapid method was designed to synthesize N-doped silicon quantum dots (N-SiQDs) with a maximum excitation wavelength and maximum emission wavelength of 347 nm and 440 nm, respectively. The prepared N-SiQDs are colorless in aqueous solution with excellent dispersibility, and the fluorescence quantum yield is 28.8%. The fluorescence intensity of the N-SiQDs decreases rapidly within 30 s in response to Hg2+ to form the Hg2+–N-SiQD system. Under physiological conditions, glutathione can coordinate with Hg2+ in the Hg2+–N-SiQD system causing Hg2+ to detach from the surface of N-SiQDs, and the fluorescence of N-SiQDs is restored within 1 min. After optimization of the N-SiQD preparation conditions and the response conditions, the linear ranges for Hg2+ and glutathione detection are 0.1–4 μM and 0.1–5 μM with the detection limits of 24 nM and 55 nM, respectively. Besides, fluorescence imaging results indicate that the “on–off–on” Hg2+–N-SiQD fluorescent sensor can be successfully applied to the detection of biothiols in living cells.

研究领域: 分析化学 · 生物医学工程 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ANALYST · 2011 ·Vol. 136 ·期 13 ·2825-2830 · IF 3.913

A one-step colorimetric method of analysis detection of Hg2+ based on an in situ formation of Au@HgS core–shell structures

Fuqiang Zhang,Leyong Zeng,Cui Yang,Junwei Xin,Haiyan Wang,Aiguo Wu

A new approach for the detection of Hg2+ is reported based on color changes from which gold nanoparticles (Au NPs) are surrounded by a layer of HgS quantum dots to form in situ Au@HgS core–shell nanostructures. The surface plasmon resonance (SPR) absorption of the gold core was changed due to a shell layer of HgS formed on the surface of the Au NPs, which brings the colour change of the aqueous solution. Therefore, Hg2+ can be recognized by visualizing the colour change of the Au@HgS core–shell nanostructures, and can be detected quantitatively by measurement of the UV-vis spectra. Some effects on the detection of Hg2+ were investigated in detail. This method was used to detect Hg2+ with excellent selectivity and high sensitivity. In our method, the lowest detected concentrations for mercury ions were 5.0 × 10−6 M observed by the naked eye and 0.486 nM as measured by UV-vis spectra. At the range from 8.0 × 10−5 to 1.0 × 10−8 M of Hg2+, this method was shown to have a good linear relationship.

研究领域: 分析化学 · 纳米技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Polymer Materials · 2026 · IF 5.2

Thioether Cyclodextrin-Incorporated Triazine-Based Porous Organic Polymer for Uptake of Iodine Vapor and Adsorption of Organic Micropollutants and Hg2+ from Water

Liu Jia,Duan Xiongcheng,Wu Zhuorui,Meng Wan,Zhang Lin,Li Hengye,Wei Meijie,Wang Zhongxia,Kong Fenying,Wang Wei

Herein, thioether cyclodextrin-incorporated triazine-based porous organic polymer (S-CD-TPOP) featuring multifunctional nature was prepared for iodine vapor uptake and adsorption of organic micropollutants (OMPs) and Hg 2+ from water. Polycondensation between specially designed per-6-(4-formylbenzylthio)-β-cyclodextrin (FB-S-CD) and 1,4-bis(2,4-diamino-1,3,5-triazine)benzene (BDTAB) affords the S-CD-TPOP containing CD cavities, thioether, and triazine units as well as high nitrogen content. S-CD-TPOP exhibits a high surface area of 467.42 m 2 /g with 28.56% nitrogen and 2.16% sulfur contents. S-CD-TPOP shows iodine vapor uptake of 1.70 g/g, where charge transfer plays a dominant role. Moreover, S-CD-TPOP displays quick adsorption kinetics and excellent removal efficiencies for phenols with a maximum adsorption capacity ( q m ) of 181.16 mg/g for bisphenol A (BPA). Host–guest and hydrophobic interactions serve as the main mechanisms for the adsorption of OMPs onto S-CD-TPOP. Additionally, S-CD-TPOP demonstrates rapid Hg 2+ adsorption kinetics with a q m value of 45.25 mg/g, primarily driven by coordination between the −S– group and Hg 2+ . Furthermore, S-CD-TPOP exhibits great application potential for simultaneously removing low concentrations BPA and Hg 2+ from river water. S-CD-TPOP also exhibits excellent reusability and is a promising and versatile adsorbent for removing diverse environmental pollutants.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2025 · IF 4.6

Narrow-bandwidth red-emitting carbon dots from Epipremnum aureum leaves: “On-Off-On” fluorescent probe for sensitive detection of Hg2+ and Thiram

Yating Xu,Tingting Lei,Pan Zhu,Shaojing Zhao,Jiafu Xiao,Minhuan Lan

Accurate and sensitive detection of mercury ions (Hg 2+ ) and thiram is essential for food safety monitoring and environmental protection. Here, an “on-off-on” fluorescent probe based on red-emitting carbon dots (CDs) was fabricated for sequential detection of Hg 2+ and thiram. The CDs exhibited red fluorescence at λ em  = 676 nm with a narrow full width at half maximum of 25 nm. Upon exposure to Hg 2+ , the fluorescence was significantly quenched due to the static quenching mechanism, achieving a limit of detection (LOD) of 25 nM. Notably, upon the addition of thiram, the quenched fluorescence of CDs was recovered due to the strong chelation between thiram and Hg 2+ , thereby enabling sensitive detection of thiram with a LOD of 4.80 nM. The approach was successfully validated using real water samples spiked with Hg 2+ and thiram. The recovery rates were between 97.16 % and 113.83 %, with relative standard deviations below 9.11 %. This study presents a simple, eco-friendly, and effective approach for the sensitive screening of trace contaminants in complex matrices.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2026 · IF 10.4

Rational design of PtBi nanoalloy-embedded nitrogen-doped porous carbon nanosphere for ultrasensitive electrochemical detection of Cd2+ and Hg2+ in food samples

Mingyue Yang,Zhiyu Zhang,Liuyan Yang,Yuntao Guan,Di Suo,Lixun Zhang

Rapid and accurate identification of heavy metals in food products is essential for ensuring food safety and public health. In this study, an electrochemical sensor based on nitrogen-doped hierarchical porous carbon nanospheres encapsulating ultrasmall PtBi nanoparticles (PtBi-HPCNs) was developed to enhance preconcentration and electrochemical deposition. The HPCNs provide abundant adsorption sites and effective mass transfer channels for metal ion enrichment, while the PtBi nanoalloys act as highly active electrocatalytic centers for metal ion reduction. Investigation of adsorption behavior and reduction kinetics reveals an “adsorption-assisted in-situ electrocatalytic reduction” mechanism. Leveraging these structural and electronic properties, the sensor enables sensitive and selective detection of Cd 2+ and Hg 2+ with low detection limits of 0.253 nM and 0.381 nM, respectively, well below Chinese regulatory limits. When applied to actual food sample detection, satisfactory recoveries of 96.80–104.53% were obtained, demonstrating its potential for practical monitoring of trace heavy metal ions in food.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS A-PHYSICAL · 2022 · IF 4.291

In-situ and ultrasensitive detection of mercury (II) ions (Hg2+) using the localized surface plasmon resonance (LSPR) nanosensor and the microfluidic chip

Wenjia Zhang,Guohua Liu,Jinqiang Bi,Kexin Bao,Peiren Wang

Mercury is one of the most dangerous heavy metals due to its extreme toxicity to both humans and the biosphere. In this work, an in-situ and ultrasensitive method for the detection of mercury (II) ions (Hg 2+ ) using the dark-field microspectroscopy-based localized surface plasmon resonance (LSPR) nanosensor is demonstrated. In our homemade high-throughput microfluidic chip, the fixed nanorods and the free small gold nanospheres combine to form the core-satellite structures with the help of T- Hg 2+ -T chemical coordination. Such a process results in a spectral red shift due to plasmonic coupling, which allows us to reach a picomolar detection limit and a linear response range from 10 pM to 10 µM. In addition, our LSPR nanosensor has excellent selectivity and no interference for the detection of Hg 2+ , which was evaluated by monitoring responses to different heavy metal ions (Pb 2+ , Cd 2+ , Cr 2+ , Ni 2+ , and Cu 2+ ) and their mixed samples. Our sensor platform's effectiveness offers a practical method for detecting traces of Hg 2+ in real-life water samples.

CAS / MDL: 7697-37-2
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
DYES AND PIGMENTS · 2022 · IF 5.122

The design of aggregation-induced fluorescence sensor based on the cetyltrimethylammonium bromide-mediated nitrogen-doped carbon dots for selective detection of Hg2+

Yayun Ji,Xue Zou,Qiumeng Chen,Yulu Tian,Zhengjun Gong,Meikun Fan

This work reported an economical and sensitive fluorescence sensor for mercury (II) ions based on the cetyltrimethylammonium bromide-mediated nitrogen-doped carbon dots (NCDs). The NCDs, obtained by a solvothermal method, exhibit emission with low quantum yield (6%) that can be quenched by various ions such as Cu 2+ , Cr 6+ , Co 2+ , and Hg 2+ . After adding cetyltrimethylammonium bromide (CTAB), the two produced aggregation-induced fluorescence effect, coupled with electrostatic interaction , and the quantum yield increased to 32%. The spatial structure formed by CTAB/NCDs could selectively capture Hg 2+ and make interact with the surface groups of NCDs to cause fluorescence quenching. The fluorescence intensity and Hg 2+ concentration showed a linear response in the range of 0.15–1 mM and 0.16–10.24 μM (R 2  = 0.998), and the detection limit was 85.71 nM. The fluorescent sensor was used to determine Hg 2+ in environmental waters with satisfactory results.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2022 · IF 4.831

A ratiometric sensor for selective detection of Hg2+ ions by combining second-order scattering and fluorescence signals of MIL-68(In)-NH2

Ning Wu,Hao Guo,Mingyue Wang,Liping Peng,Yuan Chen,Bingqing Liu,Zhilan Pan,Yinsheng Liu,Wu Yang

Ratio fluorescence has attracted much attention because of its self-calibration properties. However, it is difficult to obtain suitable fluorescent materials with well-resolved signals simultaneously under one excitation. In this work, we report a different strategy, using MIL-68(In)-NH 2 as both the fluorescence element and the scattered light unit, and coupling the fluorescence and the scattered light to construct the fluorescence and scattered light ratio system. Based on the optical properties and the second-order scattering (SOS) of the material nanoparticles , the synthesized MIL-68(In)-NH 2 can be used to realize the ratio detection of Hg 2+ . Because the scattering intensity of small particle MIL-68(In)-NH 2 is weak, SOS is not obvious. When Hg 2+ is introduced the coordination reaction between the amino nitrogen atoms of MIL-68(In)-NH 2 and Hg 2+ make the particles larger, resulting in the decrease of fluorescence and the enhancement of SOS. As a result, a novel Hg 2+ ratiometric detection method is developed by using the dual signal responses of the fluorescence and scattering. Under the optimal conditions (pH = 6, reaction time 5 min, room temperature , and the maximum excitation wavelength 365 nm), the linear range of the method is 0–100 μM, and the detection limit is 5.8 nM (Ksv = 9.89 × 10 9 M −1 ). In addition, the probe is successfully used to evaluate Hg 2+ in actual water samples. Compared with the traditional method of recording only the fluorescence signal, the proposed fluorescence-scattering method provides a new strategy for the design of ratiometric sensors.

CAS / MDL: 22519-64-8
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2022 · IF 4.598

‘On-off-on’ electrochemiluminescent aptasensor for Hg2+ based on dual signal amplification enabled by a self-enhanced luminophore and resonance energy transfer

Libo Li,Bainian Chen,Xiaohong Liu,Panao Jiang,Lijun Luo,Xia Li,Tianyan You

Divalent mercury ion (Hg 2+ ) is widely distributed in the ecological environment and harmful to the human body and the environment. Herein, a highly sensitive and selective ‘on–off-on’ electrochemiluminescence (ECL) aptamer sensing method based on the dual signal amplification strategy of a self-enhanced luminophore and ECL resonance energy transfer (ECL-RET) was developed to detect Hg 2+ . In detail, the first ‘switch-on’ state was obtained by the self-enhanced luminophore of Ru(bpy) 3 2+ -doped silica nanoparticle-nitrogen-doped graphene quantum dots ( [email protected] 2 -NGQDs) modified glassy carbon electrode, which significantly amplified the ECL intensity compared with the mixture of [email protected] 2 and NGQDs . Later, the ‘switch-off’ state was induced by gold nanoparticles (AuNPs), which acted the acceptor in the ECL-RET system between AuNPs and [email protected] 2 -NGQDs due to their good spectral overlap. This combination of the self-enhanced luminophore and ECL-RET provided a novel dual signal amplification strategy, which led to a high signal-to-noise ratio and high analysis sensitivity. Finally, upon the addition of Hg 2+ , the formation of a stable T-Hg 2+ -T structure induced the release of AuNPs from the sensing interface and halted the ECL-RET process, resulting in ECL signal recovery (the second ‘switch-on’ state). For the detection of Hg 2+ , the proposed ECL sensor exhibited a wide linear range from 1 × 10 −14 to 1 × 10 −6 M and a highly sensitive detection limit of 3.0 fM. Finally, the feasibility of the developed method in water sample analysis was investigated.

CAS / MDL: 78-10-4
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。