在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第73至84个,产品总数160个

设置提升方向
luminol
ACS Applied Materials & Interfaces · 2021 · IF 9.229

Emitter–Quencher Pair of Single Atomic Co Sites and Monolayer Titanium Carbide MXenes for Luminol Chemiluminescent Reactions

Hui Ouyang,Jiaxin Xian,Shuai Luo,Lvxia Zhang,Wenwen Wang,Zhifeng Fu

A facile, one-step doping protocol was adopted to synthesize Co single atomic site catalysts (SASCs) in UiO-66 metal–organic frameworks. In view of highly uniform active sites of Co–O6 moieties, the SASCs specifically contribute to catalyzing the generation of a large amount of singlet oxygen instead of superoxide or hydroxyl radicals, which endows Co SASCs with a the remarkable enhancement effect (∼3775 times) on luminol chemiluminescent (CL) emission. Interestingly, monolayer titanium carbide MXenes can drastically quench the CL signal of the Co SASC-boosted luminol reaction by ∼94.6% as highly efficient luminescent absorbents. Furthermore, the emitter–quencher pair of Co SASCs and titanium carbide MXenes was successfully adopted to develop an immunoassay method for cardiac troponin I (cTnI) on an immunochromatographic test strip platform. With a sandwich immunoreaction mode, a titanium carbide MXene-labeled cTnI tracer antibody was captured on the test line of a test strip, which significantly inhibited the CL response of the Co SACs-boosted luminol system. The dynamic range for quantitating cTnI is 1.0–100 pg mL–1, with a detection limit of 0.33 pg mL–1 (3σ). The test strip was successfully used to detect cTnI in human serum samples collected from cardiopathy patients. This proof-of-principle work manifests both the CL enhancement of SASCs and the quenching behavior of MXenes, which shows the thrilling prospects of combinational usage of the two functionalized nanomaterials for tracking biological recognition events.

研究领域: 分析化学 · 材料科学 · 生物医学工程 · 纳米技术
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Omega · 2018 · IF 0

Sensitive and Selective Carmine Acid Detection Based on Chemiluminescence Quenching of Layer Doubled Hydroxide–Luminol–H2O2 System

Feng Pan,Yilin Zhang,Zhiqin Yuan,Chao Lu

Carminic acid (CA) extracted from cochineal is widely used in food additives as a natural colorant, and its potential risk to human health makes its detection important. In this work, a layered doubled hydroxide (LDH)–luminol–H2O2 system-based chemiluminescence (CL) platform has been successfully applied for CA sensing. The principle detection consists of two steps: first, LDH adsorbs CA onto the surface via electrostatic attraction; second, CA quenches the CL of the LDH–luminol–H2O2 system via the synergistic effect of CL resonance energy transfer, reduction of reactive oxygen species, and occupation of positively charged centers of brucite-like layers. With this CL approach, 0.5 μM CA is detectable using a CL spectrometer, and the limit of detection is 0.03 μM. This CL system exhibited a linear response to CA in the concentration range from 0.5 to 10 μM. In addition, the practical application of the designed CL sensing system is evaluated with dried pork slice samples.

CAS / MDL: 605-32-3
研究领域: 分析化学 · 食品科学 · 生物技术
✓ 已验证 产品关联 DOI PubMed
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2023 · IF 7.4

Surface Oxygen Vacancy-Rich Co3O4 Nanowires as an Effective Catalyst of Luminol–H2O2 Chemiluminescence for Sensitive Immunoassay

Jing Lei,Ling Zhang,Mei Li,Wei Liu,Yan Jin,Baoxin Li

Oxygen vacancy is one intrinsic defect in metal oxide materials. Interestingly, we herein found that the surface oxygen vacancy can significantly enhance the catalytic activity of Co3O4 nanowires in the luminol–H2O2 chemiluminescence (CL) reaction. 0.1 ng/mL Co3O4 nanowires containing 51.3% surface oxygen vacancies possessed ca. 2.5-fold catalytic activity of free Co2+ (the best metal ionic catalyst for the luminol–H2O2 CL reaction). The superior catalytic efficiency is attributed to the enhanced adsorption of H2O2 by surface oxygen vacancies, which in turn accelerates the cleavage of O–O bonds and generates •OH radicals. More importantly, the surface oxygen vacancy-rich Co3O4 nanowires retained about 90% catalytic activity after modification with antibodies. The surface oxygen vacancy-rich Co3O4 nanowires were used to label the secondary antibody, and one sandwich-type CL immunoassay of carcinoembryonic antigen was established. The detection limit was 0.3 ng/mL with a linear range of 1–10 ng/mL. This proof-of-concept work proves that surface oxygen vacancy-rich Co3O4 nanowires are suitable for labeling biomolecules in CL bioanalysis and biosensing.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Journal of Materials Chemistry B · 2017 ·Vol. 5 ·期 35 ·7335-7341 · IF 4.543

Luminol and gold nanoparticle-co-precipitated reduced graphene oxide hybrids with long-persistent chemiluminescence for cholesterol detection

Ke Li Lin,Tong Yang,Fang Fang Zhang,Gang Lei,Hong Yan Zou,Yuan Fang Li,Cheng Zhi Huang

Herein, dual-functionalized reduced graphene oxide (rGO) hybrids (rGO/AuNP/luminol) with gold nanoparticles (AuNPs) and luminol were prepared via π–π conjugation and electrostatic interaction. The as-prepared rGO/AuNP/luminol hybrids exhibited enhanced and long-persistent chemiluminescence (CL) performance without decay for one hour when mixed with H2O2; this was due to the generation of ˙OH, O2˙−, 1O2, and π–CC˙ species. A sensitive and selective CL sensor based on the rGO/AuNP/luminol hybrid CL enhancing system was developed for cholesterol quantitation in the linear range from 0.71 to 11.43 μM with a detection limit of 0.55 μM. Furthermore, the proposed method was successfully exploited for the determination of cholesterol in human serum samples.

CAS / MDL: 50-81-7 50-99-7 51-61-6
研究领域: 分析化学 · 生物医学工程 · 纳米材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
POLYMER BULLETIN · 2023 · IF 3.2

An electrochemiluminescence aptasensor based on poly(aniline-luminol)/graphene oxide/chitosan for ultra-sensitive detection of Hg2+

Huang Jiali,Dong Ruirui,Habibul Marhaba,Zhang Yanhui,Guan Ming,Li Guixin

It is of great significance for human health and environmental monitoring to establish an ultrasensitive assay method for Hg 2+ . In this work, a label-free and highly sensitive electrochemiluminescence (ECL) aptasensor was developed for the sensitive and selective detection of Hg 2+ without additional coreactants. Poly (aniline-luminol)/graphene oxide (P(ANi-Lu)/GO) nanocomposites were prepared, and chitosan (CS) was used to modify the surface of the material positively charged. The prepared P(ANi-Lu)/GO/CS was characterized by scanning electron microscopy (TEM), UV–Vis absorption spectra, fluorescence spectra and electrochemical impedance spectroscopy. The P(ANi-Lu)/GO/CS exhibited a stable and excellent electrochemiluminescence (ECL) property. Aptamer was adsorbed on P(ANi-Lu)/GO/CS sensing interface through electrostatic interaction, and Hg 2+ was detected using T-Hg 2+ -T configuration as ECL intensity controller. The results showed that Hg 2+ can be quantitatively determined in the range of 1.0 × 10 −15 ~1.0 × 10 −7  M with a detection limit of 4.8 × 10 −16  M. Graphical abstract

CAS / MDL: 542-16-5
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2023 · IF 7.4

Enhanced Luminol Chemiluminescence with Oxidase-like Properties of FeOOH Nanorods for the Sensitive Detection of Uric Acid

Kaixiang Ji,Shiyu Xia,Xueqing Sang,Abdallah M. Zeid,Altaf Hussain,Jianping Li,Guobao Xu

FeOOH nanorods, as one-dimensional nanomaterials, have been widely used in many fields due to their stable properties, low cost, and easy synthesis, but their application in the field of chemiluminescence (CL) is rarely reported. In this work, FeOOH nanorods were synthesized by a simple and environmentally friendly one-pot hydrothermal method and used for the first time as a catalyst for generating strong CL with luminol without additional oxidant. Remarkably, luminol-FeOOH exhibits about 250 times stronger CL than the luminol-H2O2 system. Its CL intensity was significantly quenched by uric acid. We established a simple, rapid, sensitive, and selective CL method for the detection of uric acid with a linear range of 20–1000 nM and a detection limit of 6.3 nM (S/N = 3). In addition, we successfully applied this method to the detection of uric acid in human serum, and the standard recoveries were 95.6–106.4%.

CAS / MDL: 521-31-3
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2021 · IF 6.986

Plasmon-Boosted Cu-Doped TiO2 Oxygen Vacancy-Rich Luminol Electrochemiluminescence for Highly Sensitive Detection of Alkaline Phosphatase

Fuad Abduro Bushira,Shimeles Addisu Kitte,Yong Wang,Haijuan Li,Ping Wang,Yongdong Jin

In this study, an effective oxygen vacancy (Ov)-involved luminol-dissolved oxygen (O2) electrochemiluminescence (luminol-DO ECL) system was developed and exploited for ECL sensing applications through significant plasmon enhancement of the Ov-involved weak luminol-DO ECL signals by the combined use of Cu-doped TiO2 oxygen vacancy and a Au@SiO2 nanomembrane. The results disclosed that the ECL response of the corresponding system could be synergistically boosted, and the plausible underlying mechanism has been discussed. Furthermore, for the first time, the developed system has been successfully applied for the highly sensitive detection of alkaline phosphatase with a low limit of detection of 0.005 U/L, with an excellent linear range from 0.005 to 10 U/L, as well as good stability and reproducibility.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ELECTROCHIMICA ACTA · 2014 · IF 4.086

A sandwich-type label-free electrochemiluminescence immunosensor for neurotensin based on sombrero model with graphene-hyaluronate-luminol composite

Zhiyong Guo,Shuping Du,Beibei Chen,Yuhong Sha,Bin Qiu,Xiaohua Jiang,Sui Wang,Xing Li

An ultrasensitive sandwich-type label-free electrochemiluminescence (ECL) immunosensor based on sombrero model for the detection of neurotensin (NT) in human serum and urine was developed. Graphene-hyaluronate-luminol (G-HY-luminol) composite was coated on the surface of the glassy carbon electrode to build the ECL immunosensor, which gave in-situ ECL signals by luminol. A secondary NT unlabelled antibody was used to form the final sandwich immunocomplex as a sombrero model, facilitating reduction of the ECL intensity to improve the sensitivity of detection significantly. Results showed that the inhibition of ECL intensity increased with the logarithm of NT concentration within a wide linear range from 0.001   pg   cm −3 to 100   pg   cm −3 . In addition, specificity, stability, reproducibility, regeneration and application were satisfactory. Therefore, this developed ECL immunosensor has a potential for practical detection of NT and NT-like peptides with small molecular weight in the clinical diagnostics.

研究领域: 生物医学工程 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
LUMINESCENCE · 2026 ·Vol. 41 ·期 7 ·e70567 · IF 2.8

Three in One: Luminol, Hemin, and GOx-Encapsulated UiO-66 for Rapid and Sensitive Chemiluminescence Detection of Glucose

Fenqiang Luo,Liyan Zheng

Novel multifunctional metal–organic frameworks prepared by encapsulating luminol, hemin, and glucose oxidase within UiO-66 have been employed for the chemiluminescent determination of glucose via a one-step method. Benefitting from the encapsulating cascade catalyst with luminescent reagent in UiO-66, the as-prepared material can be utilized to fabricate practical glucose sensors with a wide response range, a low detection limit, and a short detection time. This promising sensing material is anticipated to have widespread applications in biotechnology and demonstrates significant potential for the green, selective, and sensitive detection of target analytes.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2026 ·Vol. 193 ·期 5 ·348 · IF 5.4

Promoting effect of peroxidase-like activity covalent organic frameworks on luminol-H2O2 cathodic electroluminescence and its sensing application

Wang Jing,Fang Zihan,Wang Xinyi,Dong Yongping,Ding Houcheng

Two covalent organic framework (COF) materials—TAPA-TFPB-COF and TAPA-BTT-COF—were synthesized through Schiff-base condensation reactions, and their catalytic performance in the luminol-H 2 O 2 cathodic electrochemiluminescence (ECL) system was systematically investigated. The results demonstrated that TAPA-BTT-COF exhibited superior peroxidase-like activity, which could effectively catalyze the decomposition of H 2 O 2 to generate reactive oxygen species (ROS) and significantly enhance the ECL intensity. Based on this catalytic mechanism, a highly sensitive and selective method for the detection of tyrosine (Tyr) was established, with a linear detection range from 1.0 × 10 − 8 to 1.0 × 10 − 4 mol L − 1 and a detection limit as low as 6.2 × 10 − 10 mol L − 1 . This study innovatively explored and utilized the intrinsic enzyme-like activity of COF materials as a substitute for traditional biological enzymes to construct a stable, cost-effective, and ultrasensitive enzyme-free ECL sensing platform, which might further expand the biosensing application of COF materials.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
RSC Advances · 2026 ·Vol. 16 ·期 30 ·27756-27764 · IF 6.1

Enzymatic electrochemiluminescence sensor based on a ternary luminol–H2O2-confined nanocatalyst system for sensitive determination of uric acid

Chunchun Wei,Mixia Chen,Wei Hu,Fei Yan,Yu Cui

An enzymatic electrochemiluminescence (ECL) sensor based on a ternary luminol system is developed for highly sensitive detection of uric acid (UA). The platform integrates nanochannel-confined platinum nanoparticle (PtNPs) and nitrogen-doped graphene quantum dot (NGQDs) nanocomposites (PtNPs–NGQDs) as coreaction accelerators, with urate oxidase (Uox) covalently immobilized at the nanochannel entrances. In this design, an amino-functionalized vertically ordered mesoporous silica film (NH2-VMSF) confined the PtNPs–NGQDs within its nanochannels, while Uox is attached to the outer surface. The confined PtNPs–NGQDs exhibit a synergistic catalytic effect, amplifying the ECL signal of the luminol–H2O2 system by 16.1-fold. In the presence of UA, immobilized Uox catalyzes its oxidation to generate H2O2, which is subsequently decomposed by the PtNPs–NGQDs nanocomposite, leading to enhanced ECL emission. Under optimized conditions, the sensor exhibits two linear response ranges for UA (0.01–1 µM and 1–50 µM) and a low detection limit of 8.1 nM (S/N = 3). The sensor also demonstrates good selectivity and stability, enabling reliable UA quantification in complex urine samples. This work provides a simple and versatile strategy for constructing sensitive ECL enzymatic platforms suitable for the detection of metabolites.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2025 · IF 10.5

Imidazole-enhanced luminol/H2O2 chemiluminescent biosensing for SARS-CoV-2 nucleocapsid protein with enzymatic regulation of hemin switch

Hang Ao,Jinshan Xiong,Wencheng Xiao,Wenrui Hu,Jie Wu,Huangxian Ju

Owing to the continuous mutations of the coronavirus, the sensitive and accurate detection of the SARS-CoV-2 nucleocapsid protein is still necessary in clinical diagnosis. Aim to the challenge of sensitivity in chemiluminescence (CL) imaging detection and the need for high-throughput clinical screening, this work used imidazole (Im) as an enhancer for hemin-DNA/luminol/H 2 O 2 CL system to propose a CL imaging method for SARS-CoV-2 nucleocapsid protein detection. In this system Im could reduce the hemin-DNA catalyzed oxidation energy of luminol by H 2 O 2 to promote the CL emission through the accelerated breaking of O-O bond of dianionic cyclic peroxide. The enhancement mechanism was demonstrated with theoretical calculations and several characterization techniques. By combining the proximity-induced initiator release with immunological recognition, an initiator-triggered DNA nanomachine was designed to achieve the release of abundant primers for activating hemin-DNA switch. This signal amplification strategy led to strong CL emission for highly sensitive imaging detection of the target. The Im-enhanced hemin-DNA/luminol/H 2 O 2 CL imaging assay exhibited a linear detection range over 4 orders of magnitude with a detection limit down to 2.75 pg/mL for SARS-CoV-2 nucleocapsid protein, exhibiting promising potential of both Im sensitization and the proposed DNA nanomachine to improve the sensitivity of high-throughput CL biosensing for the early diagnosis and clinical screening of the coronavirus and other diseases.

研究领域: 生物分析化学 · 生物传感器 · 临床诊断 · 病毒学 · 纳米生物技术
✓ 已验证 产品关联 DOI PubMed 高影响因子