2-AB Labeling Kits

货号: A492565
只有 %1 左
级别和纯度: ≥99%
价格
低至 ¥8,399.90

概述



Product Description

2-AB (2-aminobenzamide) is one of the most widely used fluorescent labels for glycosylation analysis. The 2-AB Labeling Kit includes all the reagents needed to label up to 30 glycan samples.

Kits are available with two different reducing agent types: sodium cyanoborohydride or nontoxic 2-picoline borane.

Traditional 2-AA and 2-AB labeling kits use sodium cyanoborohydride as a reducing agent during glycan labeling. This reagent is toxic, so a fume hood should be used during handling. To comply with emerging health and safety regulations, we are now replacing these kits with our new VP Glycan Kit, which uses picoline borane, a safer reducing agent.

The 2-AB Labeling Kit contains two sets of the following reagents (15 samples per kit) in glass ampoules sealed under pure nitrogen:


A492565-01-24T

2-Aminobenzamide (2-AB dye)

Dimethyl Sulfoxide (DMSO)

Acetic acid

Sodium cyanoborohydride


A492565-02-24T/A492565-03-96T

2-Aminobenzamide (2-AB dye)

Dimethyl sulfoxide (DMSO) / acetic acid solution

2-Methylpyridineborane


Number of samples:

One 2-AB labeling kit contains reagents and each kit can label up to 30 individual samples for analysis


Dye purity:

>99% by HPLC


Molecular weight:

137


Lambda-ex:

250 nm


Lambda-em:

428 nm


Sample amounts per sample ranged from 25 pmol to 25 nmol glycans.

Appropriate samples can label any purified glycan with free reducing ends.

No detectable (< 2 mol %) loss of structural integrity sialic acid, fucose, sulfate or phosphate.

Labeling efficiency is typically > 85 % (depending on the sample).

Label selectivity is essentially stoichiometric labeling.


Program

1. Purification of glycans: purify glycans from proteins, salts and detergents.


2. Transfer the sample to the reaction vial: For glycan pools obtained from typical glycoproteins, the sample volume should be between 100 picomolar and 50 nanomolar. In subsequent HPLC analysis, single pure glycans down to 5 picomolar can be labeled and detected. Suitable reaction vials include small polypropylene microcentrifuge tubes and PCR work tubes.


3. Dry the sample: If the sample volume exceeds 10 μL, dry the sample. If the sample needs to be dried, it should be dried using a centrifugal evaporator. If this is not possible, freeze-drying (lyophilization) can be used sparingly (especially to ensure that the sample dries to a small, dense mass at the bottom of the vial). Do not expose samples to high temperature (>28°C) or extreme pH conditions, as these conditions can lead to acid-catalyzed loss of sialic acid (high temperature, low pH) or glycan reducing end epimerization (at high pH) conditions). After the sample has dried, redissolve the glycans in 10 μL of water.


4. Prepare the DMSO-acetic acid mixture: Add 150 µL of glacial acetic acid to the DMSO vial and mix by pipette motion.


5. Add the dye: Add the DMSO-acetic acid mixture to a bottle of 2-AB (2-aminobenzamic acid) dye and mix until the dye dissolves.


6. Add the reducing agent: Add the dissolved dye to a vial of sodium cyanoborohydride or picoline borane and mix with a pipette until the reducing agent is completely dissolved to make the final labeling reagent.


7. Add labeling reagent to samples: Add labeling reagent to each dried glycan sample, cap the microtube, and mix well.


8. Incubation: Incubate the reaction vial in a heating block, sand tray, or drying oven set to 65°C for 3 hours. In most cases, the incubation time can be shortened to 2 hours or extended to 4 hours without significantly altering the results of the labeling reaction.


9. Centrifugation and cooling: After the incubation period, remove the samples, centrifuge the microtubes briefly, and allow them to cool completely to room temperature.


10. Sample clean-up: It is recommended to clean the labeled sample to remove excess dye and other labeling reagents. Purification can be achieved with a T1 or S-filter

规格

别名
2-AB 标记试剂盒
规格或纯度
≥99%
英文名称
2-AB Labeling Kits
纯度
≥99%
敏感性
对湿度、光、热 敏感
储存与运输
储存条件
避光,室温
运输条件
常规运输

技术文档

📋 安全数据表 (SDS)

全面的危险、操作、储存及法规合规文件。

下载 SDS →

✅ 分析证书 (COA)

批次质量数据。输入批号以获取对应 COA。

查询 COA →

📊 产品数据表

产品规格和应用的快速参考摘要。

查看数据表 →

🔬 规格说明书

该级别的完整质量属性和验收标准。

查看规格说明 →

高级数据

质检证书(CoA,COO,BSE/TSE 和分析图谱)
C of A & Other Certificates(BSE/TSE, COO):
输入批号以搜索分析图谱:

通过匹配包装上的批号来查找并下载产品的 COA,每批产品都进行了严格的验证,您可放心使用!

找到3个结果

批号(Lot Number) 证书类型 货号
H2324096 分析证书 A492565
H2324097 分析证书 A492565
H2606083 分析证书 A492565
技术文档和文章