文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第61至72个,产品总数94个

设置提升方向
Ru[bpy]32
FOOD CHEMISTRY · 2022 · IF 9.231

A molecule-imprinted electrochemiluminescence sensor based on self-accelerated Ru(bpy)32+@ZIF-7 for ultra-sensitive detection of procymidone

Xin Zhang,Li Tian,Zhuo Sun,Qian Wu,Xiangyu Shan,Yingjie Zhao,Ruizhan Chen,Juan Lu

A molecular-imprinted electrochemiluminescence sensor for procymidone (PCM) detection was reported based on Ru(bpy) 3 2+ @ZIF-7. A novel self-accelerated Ru(bpy) 3 2+ @ZIF-7 was prepared by one-step synthesis method, which exhibited high electrochemiluminescence (ECL) emission as a coreactant in the presence of tri- n -propylamine (TPrA). Concretely, ZIF-7 was not only the carrier of Ru(bpy) 3 2+ , but also the co-reaction promoter of Ru(bpy) 3 2+ /TPrA ECL system. The introduction of molecular imprint polymer (MIP) with PCM gave new characteristics of specific recognition of analyte PCM. The change value of ECL intensity (ΔI) was proportional to the logarithm of PCM concentration, with a wide linear range and a low detection limit of 1.0 × 10 −10 to 1.0 × 10 −6  mol L −1 and 2.0 × 10 −11  mol L −1 , respectively. The presented MIP-ECL sensor had high sensitivity, selectivity and stability, and had great potential in the field of food safety detection.

研究领域: 分析化学 · 食品安全检测
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
International Journal of Electrochemical Science · 2023 · IF 1.5

A Novel Electrochemiluminescence Modified Glasss Carbon Electrode Based on Carboxylated Acetylene Black / Ru(bpy)32+ / Nafion for Detection of Isoniazid

Jing-yi Jiang,Qingyi Li,Wen-chang Wang,Xiao-hui Chen,Zhi-dong Chen

A novel, rapid, and facile electrochemiluminescence sensor which based on carboxylated acetylene black / Ru(bpy) 3 2+ / nafion modified glass carbon electrode (CAB/Ru(bpy) 3 2+ /NAF/GCE) was developed for detecting isoniazid (INH). The CAB/Ru(bpy) 3 2+ /NAF/GCE expresses an efficient electrochemiluminescence response for INH, because of the brilliant luminous efficiency of Ru(bpy)32+ and admirable electronic transmission of acetylene black. The electrochemiluminescence intensity was quenched significantly with addition of INH. Under the optimal conditions, the sensor for the detection of isoniazid exhibits a wide linear range of 1.0 × 10 -6 ~ 1.0 × 10 -3 mol·L -1 with the detection limit of 5.0 × 10 -7 mol·L -1 . The sensor is expected to be a simple and convenient method for the determination of INH in pharmaceutical samples .

研究领域: 分析化学 · 药物分析
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
TALANTA · 2023 · IF 6.1

Electrochemiluminescence resonance energy transfer between Ru(bpy)32+@Cu3(HHTP)2 and GO-Au composites for C-reactive protein detection

Chen Cui,Xinyao Lin,Jie Lv,Hang Guo,Lu Shen,Guoqiang Xiang,Wenjie Zhao,Dechen Jiang

Designing innovative electrochemiluminescence (ECL) immunosensors is critical for the detection of biomarkers with a low concentration and the precise evaluation of clinical diseases. Herein, a Cu 3 (hexahydroxytriphenylene) 2 (Cu 3 (HHTP) 2 ) nanoflake-based sandwich-type ECL immunosensor was constructed for C-Reactive Protein (CRP) detection. The Cu 3 (HHTP) 2 nanoflake , an electronically conductive metal–organic framework (MOF), has a periodically arranged porous structure with a cavity size of 2 nm, which not only accommodates a large amount of Ru(bpy) 3 2+ but also confines the spatial diffusion of active species. Therefore, the Ru(bpy) 3 2+ -loaded Cu 3 (HHTP) 2 nanocomplex (Ru@CuMOF) as an ECL emitter exhibits an enhanced ECL efficiency. The ECL resonance energy transfer (ECL-RET) was accomplished by combining Ru@CuMOF used as a donor with gold nanoparticles-functionalized graphene oxide nanosheets (GO-Au) utilized as an acceptor. This should be ascribed to the fact that the ECL emission spectrum of Ru@CuMOF shows the strongest signal intensity at 615 nm, overlapping with the absorption spectrum of GO-Au at 580–680 nm. Targeted detection of CRP in human serum samples was achieved by the sandwich-type immunosensor based on the ECL-RET mechanism with a 0.26 pg mL −1 detection limit. The electro-activated hybrids of Cu 3 (HHTP) 2 and ECL emitters provide a new sensing strategy for the high-sensitivity detection of disease markers.

研究领域: 生物医学工程 · 分析化学 · 临床诊断
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2026 · IF 9.8

A dual-mode electrochemiluminescence-electrochemical sensor based on Ru(bpy)32+@Ti3CN and Zn4Sn3O5 for highly sensitive detection of sodium saccharin

Ruidan Li,Li Tian,Yujia Song,Yanjia Guo,Guangping Ma,Pengfei Han,Hanyue Jiang,Wenzhuo Wang,Tengying Ma

In this paper, a dual-mode electrochemiluminescence-electrochemical (ECL-EC) sensor was constructed using Ru(bpy) 3 2+ @Ti 3 CN and Zn 4 Sn 3 O 5 via multi-step amplification strategy for the detection of sodium saccharin (SS). The maximum ECL/EC initial signals were obtained by the synergistic action of Ru(bpy) 3 2+ @Ti 3 CN and Zn 4 Sn 3 O 5 in the tri-n-propylamine (TPrA) solution. Given that SS reacted with Ru(bpy) 3 2+ , the ECL/EC signal values both decreased. The relevant mechanism was investigated. Under the best optimization conditions, the ECL detection exhibited a linear range of 5.0 × 10 −15 to 5.0 × 10 −10  mol·L −1 with a limit of detection (LOD) of 1.67 × 10 −15  mol·L −1 (S/N = 3), while EC detection showed a linear range of 5.0 × 10 −9 to 5.0 × 10 −4  mol·L −1 with the LOD of 1.67 × 10 −9  mol·L −1 (S/N = 3). Satisfactory results were obtained in a variety of actual samples.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MOLECULES · 2025 ·Vol. 30 ·期 15 ·3130 · IF 4.6

A Turn-On Fluorescence Sensor Based on Guest-Induced Luminescence Ru(bpy)32+@UiO-66 for the Detection of Organophosphorus Pesticides

Jun Li,Jianlan Deng,Qian Tao,Chenyu Yan,Yuxuan Liu,Jianxiao Yang,Zhong Cao

Luminescent metal–organic frameworks (MOFs) are used for the detection of organophosphorus pesticides (OPs) due to their large surface area and pore volume as well as their special optical properties. However, most self-luminescent MOFs are not only complex to synthesize and unstable in water but also feature a “turn-off” sensing system, which has highly restricted their practical applications in OP detection. Herein, a “turn-on” fluorescence sensor based on the guest-induced luminescence MOF Ru(bpy)32+@UiO-66 was constructed, which realized the sensitive detection of OPs through a dual-enzyme system for the first time. Compared with self-luminescent MOFs, Ru(bpy)32+@UiO-66 was not only more easily synthesized but also had higher chemical and photostability in water. In this strategy, by means of the hydrolysis of AChE and ChOx, H2O2will be produced, which can oxidize Fe2+to Fe3+, thereby quenching the fluorescence of Ru(bpy)32+@UiO-66. In the presence of OPs, the activity of AChE can be inhibited, resulting in the inability to generate H2O2and Fe3+, which will turn on the fluorescence signal of Ru(bpy)32+@UiO-66. As a result, the Ru(bpy)32+@UiO-66 sensing system not only had high sensitivity for OPs detection but also possessed a satisfactory detection recovery rate for parathion-methyl in real samples, which provides a new approach for OP detection in food safety as well as environmental monitoring.

研究领域: 分析化学 · 材料科学 · 环境科学 · 生物化学 · 食品科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2019 ·Vol. 186 ·期 8 ·1-10 · IF 5.479

A ratiometric electrochemiluminescent tetracycline assay based on the combined use of carbon nanodots, Ru(bpy)32+, and magnetic solid phase microextraction

Hu Yunxia,Su Luyao,Wang Sui,Guo Zhiyong,Hu Yufang,Xie Hongzhen

A method is described for combined magnetic solid phase microextraction and electrochemiluminescent (ECL) detection of the antibiotic tetracycline. A nanocomposite of type Fe 3 O 4 @SiO 2 @ZnO was used as the sorbent. Tetracycline has a strong affinity for Zn(II) ion and therefore is well extracted by this sorbent. The loaded sorbent can be magnetically removed. The extraction efficiency at a 1.0 μM tetracycline concentration is around 88%. Detection is based on the use of carbon nanodots that were prepared form urea and ethylenediaminetetraacetic acid as raw materials. The electrochemical probe Ru(bpy) 3 2+ was added to generate double ECL when scanning the potential between −3.5 and + 2 V. The two ECL signals decreased with the increase of tetracycline concentration. Under optimized experimental conditions, the ratio of the two signals is linearly related to the logarithm of the tetracycline concentration in the range from 1.0 nM to 0.1 mM, with a 0.47 nM detection limit. The method was successfully applied to the determination of tetracycline in spiked milk. It exhibited good sensitivity, selectivity and accuracy due to ratiometric read-out and prior preconcentration of analyte. Tetracycline (TC) has a strong affinity for Zn(II) ion and is well extracted by the Fe 3 O 4 @SiO 2 @ZnO nanocomposite. Ru(bpy) 3 2+ can generate double electrochemiluminescence signals based on the use of carbon nanodots (C-dots) as coreactant. The two signals decrease with the increase of tetracycline concentration. [Ru(bpy) 3 2+ ]* stands for excited state Ru(bpy) 2 2+ .

研究领域: 分析化学 · 环境科学 · 药物分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2023 · IF 4.8

Molecularly imprinted poly(o-phenylenediamine) coated ZIF-5-Ru(bpy)32+ composite for the sensitive and selective ECL detection of tetracycline

Ziying Zhong,Yun Tang,Yanran Chen,Chunfang Wang,Faqiong Zhao,Baizhao Zeng

The widespread use of tetracycline unavoidably causes residue problems, hence its monitor in foods and environment is important. In this work, a simple but sensitive electrochemiluminescence (ECL) sensor is prepared for tetracycline detection. The sensor is constructed using TiO 2 nanoparticle, ZIF-5 loaded Ru(bpy) 3 2+ (Ru@ZIF-5), and molecularly imprinted poly-o-phenylenediamine. The TiO 2 NP acts as a co-reaction accelerator for tri-n-propylamine (TPrA) by producing electrons and holes at a certain potential to promote the production of TPrA . ZIF-5 has a large specific surface area and rich functional groups, thus can well immobilize a large amount of illuminant Ru(bpy) 3 2+ . The electrodeposited molecularly imprinted polymer acts as a recognition element. Due to the synergic effect of different components, the resulting ECL sensor shows a wide linear range of 10 nM–50 μM, high selectivity, low detection limit, and good stability. It can be used for the detection of tetracycline in food and environmental samples.

研究领域: 分析化学 · 环境科学 · 食品科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2018 ·Vol. 10 ·期 13 ·1560-1564 · IF 2.073

Encapsulating a ruthenium(II) complex into metal organic frameworks to engender high sensitivity for dopamine electrochemiluminescence detection

Yang Li,Liu Yang,Zhewei Peng,Chengzhi Huang,Yuanfang Li

In this contribution, an ultra-sensitive electrochemiluminescence (ECL) sensor was proposed for dopamine (DA) detection based on ruthenium(II) complex (tris(2,2-bipyridyl)dichlororuthenium(II) hexahydrate, Ru(bpy)32+) functionalized Zn(II) metal–organic frameworks (Ru-MOFs). The Ru-MOFs, with large internal surface areas and abundant Ru(bpy)32+ encapsulated effectively, could act as a suitable ECL emitter in a DA detection system. The leakage of Ru molecules in the encapsulation system could be effectively prevented, which resulted in stable ECL signals and significantly improved the ECL performance. On the basis of the novel Ru-MOFs as efficient ECL tags, the as-prepared simple and label-free ECL sensor was employed to quantify dopamine, which showed an excellent linear response from 0.1 pM to 10 nM and a detection limit of 0.024 pM. The simple and sensitive strategy might be expanded to other applications in analysis and detection fields based on functional metal–organic frameworks.

CAS / MDL: 102-69-2
研究领域: 分析化学 · 材料科学 · 电化学 · 传感器
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Sensors and Actuators Reports · 2025 · IF 7.6

Unveiling MOF-derived CuFe2O4 as a catalytic promoter of Ru(bpy)32⁺ ECL: A CRISPR/Cas13a-based strategy for miR-17 Detection

Yanli Sun,Hongying Li,Tao Wang,Kai Zhang,Xueliang Wang

MicroRNA-17 (miR-17) is a critical biomarker linked to various cancers and diseases, underscoring the need for sensitive and selective detection methods. Herein, an ultra-sensitive electrochemiluminescent (ECL) sensor for miR-17 detection utilizing MOF-derived porous CuFe 2 O 4 nanospheres and CRISPR/Cas13a trans-cleavage-triggered hybridization chain reaction (HCR) amplification was presented. The porous CuFe 2 O 4 nanospheres possessed a high surface area and excellent catalytic activity, significantly enhancing ECL emission. To the best of our knowledge, this is the first report demonstrating that MOF-derived CuFe 2 O 4 can effectively enhance the electrochemiluminescence of Ru(bpy) 3 2 ⁺ for miR-17 detection. The CRISPR/Cas13a system provided miR-17 recognition and trans-cleavage activity, triggering HCR for signal amplification. Under optimized conditions, the biosensor exhibited a wide linear detection range from 20 aM to 5000 aM, with a detection limit of 9.23 aM. The system discriminated miR-17 from closely related miRNAs with negligible cross-reactivity, which demonstrated its outstanding selectivity. Practical applicability was confirmed by successful quantification of miR-17 in diluted human serum which achieved recovery rates between 95.2% and 104.8%. The results validated the biosensor’s potential for early disease diagnosis and clinical monitoring of miR-17-associated disorders.

CAS / MDL: 25952-53-8 6066-82-6
研究领域: 生物传感器 · 分析化学 · 纳米材料 · 分子诊断 · 癌症研究
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2020 · IF 3.807

A sensitive method to monitor catechol by using graphitic carbon nitride quantum dots as coreactants in Ru(bpy)32+-based electrochemiluminescent system

Zhimin Liu,Hao Wu,Xianguo Ge,Haijun Zhan,Leqian Hu

Graphitic carbon nitride quantum dots (g-CNQDs) with special structures have exhibited fascinating advantages over the common QDs. In this work, we report a novel Ru(bpy) 3 2+ /g-CNQDs electrochemiluminescence (ECL) system, and the effect of g-CNQDs on the ECL signal of Ru(bpy) 3 2+ was discussed. It was found that g-CNQDs containing in proposed ECL system played an important coreactant role in ECL signal enhancement of Ru(bpy) 3 2+ , which was proved by electrochemical, ultraviolet, and ECL experiments. Based on the quenching effect of catechol on the ECL signal of Ru(bpy) 3 2+ /g-CNQDs, a quenching-based ECL system was designed for catechol determination. The ECL sensing system demonstrated high sensitivity to catechol, with a linear range from 10 nM to 2 mM and a detection limit of 2.5 nM (S/N = 3). The sensor was adopted for catechol analysis in tea samples with satisfactory results.

研究领域: 分析化学 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ELECTROANALYSIS · 2023 ·Vol. 35 ·期 9 ·e202300052 · IF 3

A sensitive DNA biosensor based on the distance dependent quenching of Silica@Ru(bpy)32+-chitosan-GO electrochemiluminescence by Ferrocene@Gold nanoparticles

Qiaoyu Ding,Xi Bai,Jiali Ju,Jiajun Shi,Guixin Li

A sensitive electrochemiluminescence (ECL) biosensor for the specific DNA sequence of hepatitis C virus (HCV) was developed based on the efficient quenching effect of the ferrocene cluster functionalized gold nanoparticles (Fc@AuNPs) on the ECL of electrodeposited silica@Ru(bpy) 3 2+ -chitosan-graphene oxide nanocomposite (SiO 2 @Ru−CS−GO). Graphene oxide (GO) can accelerate electron transfer rate, thus improving the ECL of Ru(bpy) 3 2+ on electrode surface. The molecular beacons (MB) was fixed to SiO 2 @Ru−CS−GO by glutaraldehyde (GA) using the Schiff reaction between amino groups of chitosan (CS) and MB. The ECL of SiO 2 @Ru−CS−GO was depressed greatly by the Fc@AuNPs labelled at the end of MB, then, a stronger ECL was observed when the distance between Fc@AuNPs and SiO 2 @Ru−CS−GO increased after the hybridization of target DNA with MB. Under optimum conditions, the restored ECL intensity increased linearly with the target DNA concentration in the range of 1.0×10 −16 ∼1.0×10 −10 mol ⋅ L −1 , and the limit of detection (LOD) is 1.4×10 −17 mol ⋅ L −1 . The proposed method exhibits acceptable stability and reproducibility. In general, the constructed HCV biosensor can be used for the sensitive detection of HCV in human serum, suggesting potential application prospects in bioanalysis.

研究领域: 分析化学 · 生物传感器 · 医学检测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Nano Materials · 2026 · IF 5.8

Visualized Solvent Polarity Sensor Based on Dual-Fluorescent Perovskite Quantum Dots–Ru(bpy)32+@SiO2 Nanocomposites for the Detection of Solvent Polarity

Weiwei Zhang,Dongqin Ye,Jingcheng Zheng,Yuwu Chi

Determination of the solvent polarity is important across various scientific and industrial fields. Classic empirical parameters for evaluating solvent polarity, such as Rohrschneider–Snyder parameters (P′), Reichardt’s ET(30), Kamlet–Taft parameters, dielectric constant (ε) measurement, and Hansen solubility parameters (HSPs) often suffer from complicated instrumentation and measurement operation, which seriously limits their applications in real-time and fast determination and selection of unknown solvent polarity. In this work, we utilize recently emerging perovskite quantum dots (PQDs) with extremely high fluorescence quantum yield, high sensitivity to solvent polarity, and facile preparation and surface engineering to to develop a visualized and disposable solvent polarity sensor based on dual-fluorescent PQDs@SiO2/Ru(bpy)32+@SiO2 (PQDs@SiO2/Ru(II)@SiO2) nanocomposites. Among the nanocomposites, the components of PQDs@SiO2 are stable in nonpolar solvents but not stable in polar solvents due to degradation. Meanwhile, the component Ru(bpy)32+ is stable in both polar and nonpolar solvents, giving a constant red background fluorescence. Therefore, when inserting the glass slide loaded with PQDs@SiO2/Ru(II)@SiO2 nanocomposites into a nonpolar solvent, it retainss green light emission since the fluorescence quantum yield of PQDs is much larger than that of Ru(bpy)32+. In contrast, when the glass slide contacts with polar solvents, its fluorescence color will change from green to yellow, then orange, and finally to red due to the instability of PQDs in this case. The complete color change time from initial green to final red (tccc) was proposed as a new type of solvent polarity parameter. This work not only provides an empirical parameter for evaluating solvent polarity but also opens up an avenue for detecting solvent polarity using functional nanomaterial.

CAS / MDL: 534-17-8
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。